Literature DB >> 25146882

Comparison of flow cytometry, fluorescence microscopy and spectrofluorometry for analysis of gene electrotransfer efficiency.

Igor Marjanovič1, Maša Kandušer, Damijan Miklavčič, Mateja Manček Keber, Mojca Pavlin.   

Abstract

In this study, we compared three different methods used for quantification of gene electrotransfer efficiency: fluorescence microscopy, flow cytometry and spectrofluorometry. We used CHO and B16 cells in a suspension and plasmid coding for GFP. The aim of this study was to compare and analyse the results obtained by fluorescence microscopy, flow cytometry and spectrofluorometry and in addition to analyse the applicability of spectrofluorometry for quantifying gene electrotransfer on cells in a suspension. Our results show that all the three methods detected similar critical electric field strength, around 0.55 kV/cm for both cell lines. Moreover, results obtained on CHO cells showed that the total fluorescence intensity and percentage of transfection exhibit similar increase in response to increase electric field strength for all the three methods. For B16 cells, there was a good correlation at low electric field strengths, but at high field strengths, flow cytometer results deviated from results obtained by fluorescence microscope and spectrofluorometer. Our study showed that all the three methods detected similar critical electric field strengths and high correlations of results were obtained except for B16 cells at high electric field strengths. The results also demonstrated that flow cytometry measures higher values of percentage transfection compared to microscopy. Furthermore, we have demonstrated that spectrofluorometry can be used as a simple and consistent method to determine gene electrotransfer efficiency on cells in a suspension.

Mesh:

Substances:

Year:  2014        PMID: 25146882     DOI: 10.1007/s00232-014-9714-4

Source DB:  PubMed          Journal:  J Membr Biol        ISSN: 0022-2631            Impact factor:   1.843


  39 in total

1.  Electropermeabilization of cell membranes.

Authors: 
Journal:  Adv Drug Deliv Rev       Date:  1999-01-04       Impact factor: 15.470

2.  Clinical applications of electrochemotherapy.

Authors: 
Journal:  Adv Drug Deliv Rev       Date:  1999-01-04       Impact factor: 15.470

3.  Analysis and comparison of electrical pulse parameters for gene electrotransfer of two different cell lines.

Authors:  Igor Marjanovic; Sasa Haberl; Damijan Miklavcic; Masa Kanduser; Mojca Pavlin
Journal:  J Membr Biol       Date:  2010-07-20       Impact factor: 1.843

4.  The role of electrophoresis in gene electrotransfer.

Authors:  M Pavlin; K Flisar; M Kanduser
Journal:  J Membr Biol       Date:  2010-07-18       Impact factor: 1.843

5.  Mechanisms involved in gene electrotransfer using high- and low-voltage pulses--an in vitro study.

Authors:  Masa Kanduser; Damijan Miklavcic; Mojca Pavlin
Journal:  Bioelectrochemistry       Date:  2008-09-21       Impact factor: 5.373

6.  Electro-mediated gene transfer and expression are controlled by the life-time of DNA/membrane complex formation.

Authors:  Cécile Faurie; Matej Rebersek; Muriel Golzio; Masa Kanduser; Jean-Michel Escoffre; Mojca Pavlin; Justin Teissie; Damijan Miklavcic; Marie-Pierre Rols
Journal:  J Gene Med       Date:  2010-01       Impact factor: 4.565

7.  High-efficiency gene transfer into skeletal muscle mediated by electric pulses.

Authors:  L M Mir; M F Bureau; J Gehl; R Rangara; D Rouy; J M Caillaud; P Delaere; D Branellec; B Schwartz; D Scherman
Journal:  Proc Natl Acad Sci U S A       Date:  1999-04-13       Impact factor: 11.205

8.  Electrochemotherapy, a new antitumor treatment. First clinical phase I-II trial.

Authors:  M Belehradek; C Domenge; B Luboinski; S Orlowski; J Belehradek; L M Mir
Journal:  Cancer       Date:  1993-12-15       Impact factor: 6.860

Review 9.  Antitumor effectiveness of electrochemotherapy: a systematic review and meta-analysis.

Authors:  B Mali; T Jarm; M Snoj; G Sersa; D Miklavcic
Journal:  Eur J Surg Oncol       Date:  2012-09-11       Impact factor: 4.424

10.  Phase I trial of interleukin-12 plasmid electroporation in patients with metastatic melanoma.

Authors:  Adil I Daud; Ronald C DeConti; Stephanie Andrews; Patricia Urbas; Adam I Riker; Vernon K Sondak; Pamela N Munster; Daniel M Sullivan; Kenneth E Ugen; Jane L Messina; Richard Heller
Journal:  J Clin Oncol       Date:  2008-11-24       Impact factor: 44.544

View more
  6 in total

1.  Analysis of In Vitro Cytotoxicity of Carbohydrate-Based Materials Used for Dissolvable Microneedle Arrays.

Authors:  Ezgi P Yalcintas; Daniel S Ackerman; Emrullah Korkmaz; Cheryl A Telmer; Jonathan W Jarvik; Phil G Campbell; Marcel P Bruchez; O Burak Ozdoganlar
Journal:  Pharm Res       Date:  2020-01-15       Impact factor: 4.200

2.  Fundamental study on a gene transfection methodology for mammalian cells using water-in-oil droplet deformation in a DC electric field.

Authors:  Hirofumi Kurita; Yasuhiro Takao; Kenta Kishikawa; Kazunori Takashima; Rika Numano; Akira Mizuno
Journal:  Biochem Biophys Rep       Date:  2016-08-12

3.  Precision modification of the human gut microbiota targeting surface-associated proteins.

Authors:  Raquel Marcos-Fernández; Lorena Ruiz; Aitor Blanco-Míguez; Abelardo Margolles; Borja Sánchez
Journal:  Sci Rep       Date:  2021-01-14       Impact factor: 4.379

4.  Transfection types, methods and strategies: a technical review.

Authors:  Zhi Xiong Chong; Swee Keong Yeap; Wan Yong Ho
Journal:  PeerJ       Date:  2021-04-21       Impact factor: 2.984

Review 5.  Non-Viral in Vitro Gene Delivery: It is Now Time to Set the Bar!

Authors:  Nina Bono; Federica Ponti; Diego Mantovani; Gabriele Candiani
Journal:  Pharmaceutics       Date:  2020-02-21       Impact factor: 6.321

6.  A Medium-Throughput System for In Vitro Oxidative Stress Assessment in IPEC-J2 Cells.

Authors:  Miriam Ayuso; Steven Van Cruchten; Chris Van Ginneken
Journal:  Int J Mol Sci       Date:  2020-10-01       Impact factor: 5.923

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.