| Literature DB >> 2514613 |
H Kawasaki1, K Sato, J Ogawa, Y Hasegawa, H Yuki.
Abstract
A flow injection method with chemiluminescence detection has been developed for the enzymatic determination of inorganic phosphate. Purine nucleoside phosphorylase, xanthine oxidase, and urate oxidase were immobilized on controlled-pore glass beads. Hydrogen peroxide released by the enzymatic reactions of phosphate and inosine in carrier buffer was detected by the luminol-microperoxidase system in a flow cell. The calibration graph was linear over the range of 5 to 250 pmol, and reproducibility was 1.75% at 10 pmol. The detection limit was 500 fmol of phosphate in 50 microliters of sample injected. The phosphate content in deoxyribonucleic acid was measured by this method.Entities:
Mesh:
Substances:
Year: 1989 PMID: 2514613 DOI: 10.1016/0003-2697(89)90609-x
Source DB: PubMed Journal: Anal Biochem ISSN: 0003-2697 Impact factor: 3.365