Abstract

BACKGROUND: CT perfusion images have a high contrast ratio between voxels representing different anatomy, such as tissue or vessels, which makes image segmentation of tissue and vascular regions relatively easy. However, grey and white matter tissue regions have relatively low values and can suffer from poor signal to noise ratios. While smoothing can improve the image quality of the tissue regions, the inclusion of much higher valued vascular voxels can skew the tissue values. It is thus desirable to smooth tissue voxels separately from other voxel types, as has been previously implemented using mean filter kernels. We created a novel Masked Smoothing method that performs Gaussian smoothing restricted to tissue voxels. Unlike previous methods, it is implemented as a combination of separable kernels and is therefore fast enough to consider for clinical work, even for large kernel sizes.
METHODS: We compare our Masked Smoothing method to alternatives using Gaussian smoothing on an unaltered image volume and Gaussian smoothing on an image volume with vascular voxels set to zero. Each method was tested on simulation data, collected phantom data, and CT perfusion data sets. We then examined tissue voxels for bias and noise reduction.
RESULTS: Simulation and phantom experiments demonstrate that Masked Smoothing does not bias the underlying tissue value, whereas the other smoothing methods create significant bias. Furthermore, using actual CT perfusion data, we demonstrate significant differences in the calculated CBF and CBV values dependent on the smoothing method used.
CONCLUSION: The Masked Smoothing is fast enough to allow eventual clinical usage and can remove the bias of tissue voxel values that neighbor blood vessels. Conversely, the other Gaussian smoothing methods introduced significant bias to the tissue voxels.

Entities:  

Mesh:

Year:  2014        PMID: 25145879      PMCID: PMC4155389          DOI: 10.1186/1471-2342-14-28

Source DB:  PubMed          Journal:  BMC Med Imaging        ISSN: 1471-2342            Impact factor:   1.930


  8 in total

1.  Quantitative cerebral blood flow measurement with dynamic perfusion CT using the vascular-pixel elimination method: comparison with H2(15)O positron emission tomography.

Authors:  Kohsuke Kudo; Satoshi Terae; Chietsugu Katoh; Masaki Oka; Tohru Shiga; Nagara Tamaki; Kazuo Miyasaka
Journal:  AJNR Am J Neuroradiol       Date:  2003-03       Impact factor: 3.825

2.  Automatic segmentation of intracranial arteries and veins in four-dimensional cerebral CT perfusion scans.

Authors:  Adriënne Mendrik; Evert-Jan Vonken; Bram van Ginneken; Ewoud Smit; Annet Waaije; Giovanna Bertolini; Max A Viergever; Mathias Prokop
Journal:  Med Phys       Date:  2010-06       Impact factor: 4.071

3.  Image quality in CT perfusion imaging of the brain. The role of iodine concentration.

Authors:  Matthias König; Eva Bültmann; Lucas Bode-Schnurbus; Dirk Koenen; Eckhart Mielke; Lothar Heuser
Journal:  Eur Radiol       Date:  2006-05-16       Impact factor: 5.315

4.  Perfusion measurements of the brain: using dynamic CT for the quantitative assessment of cerebral ischemia in acute stroke.

Authors:  E Klotz; M König
Journal:  Eur J Radiol       Date:  1999-06       Impact factor: 3.528

5.  MATHEMATICAL METHODS IN MEDICAL IMAGE PROCESSING.

Authors:  Sigurd Angenent; Eric Pichon; Allen Tannenbaum
Journal:  Bull New Ser Am Math Soc       Date:  2006       Impact factor: 2.731

6.  Robust smoothing of gridded data in one and higher dimensions with missing values.

Authors:  Damien Garcia
Journal:  Comput Stat Data Anal       Date:  2010-04-01       Impact factor: 1.681

7.  TIPS bilateral noise reduction in 4D CT perfusion scans produces high-quality cerebral blood flow maps.

Authors:  Adriënne M Mendrik; Evert-jan Vonken; Bram van Ginneken; Hugo W de Jong; Alan Riordan; Tom van Seeters; Ewoud J Smit; Max A Viergever; Mathias Prokop
Journal:  Phys Med Biol       Date:  2011-06-08       Impact factor: 3.609

8.  Differences in CT perfusion maps generated by different commercial software: quantitative analysis by using identical source data of acute stroke patients.

Authors:  Kohsuke Kudo; Makoto Sasaki; Kei Yamada; Suketaka Momoshima; Hidetsuna Utsunomiya; Hiroki Shirato; Kuniaki Ogasawara
Journal:  Radiology       Date:  2010-01       Impact factor: 11.105

  8 in total
  2 in total

1.  Multi-Sequence MRI Registration of Atherosclerotic Carotid Arteries Based on Cross-Scale Siamese Network.

Authors:  Xiaojie Huang; Lizhao Mao; Xiaoyan Wang; Zhongzhao Teng; Minghan Shao; Jiefei Gao; Ming Xia; Zhanpeng Shao
Journal:  Front Cardiovasc Med       Date:  2021-12-24

2.  Postreconstruction filtering of 3D PET images by using weighted higher-order singular value decomposition.

Authors:  Hongbo Liu; Kun Wang; Jie Tian
Journal:  Biomed Eng Online       Date:  2016-08-27       Impact factor: 2.819

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.