Literature DB >> 25144819

Microwave ablation of malignant hepatic tumours: intraperitoneal fluid instillation prevents collateral damage and allows more aggressive case selection.

Douglas Kitchin1, Meghan Lubner, Tim Ziemlewicz, J Louis Hinshaw, Marci Alexander, Christopher L Brace, Fred Lee.   

Abstract

PURPOSE: Theaim of this peper was to retrospectively review our experience utilising protective fluid instillation techniques during percutaneous microwave ablation of liver tumours to determine if fluid instillation prevents non-target injuries and allows a more aggressive case selection.
MATERIALS AND METHODS: This institute review board-approved, U.S. Health Insurance Portability and Accountability Act-compliant, retrospective study reviewed percutaneous microwave ablation of 151 malignant hepatic tumours in 87 patients, comparing cases in which protective fluid instillation was performed with those where no fluid was utilised. In cases utilising hydrodisplacement for bowel protection, a consensus panel evaluated eligibility for potential ablation without hydrodisplacement. Patient age, tumour size, local tumour progression rate, length of follow-up, complications, displacement distance/artificial ascites thickness, and treatment power/time were compared.
RESULTS: Fluid administration was utilised during treatment in 29/151 of cases: 10/29 for protection of bowel (8/10 cases not possible without fluid displacement), and 19/29 for body wall/diaphragm protection. Local tumour progression was higher when hydrodisplacement was used to protect bowel tissue; this may be due to lower applied power due to operator caution. Local tumour progression was not increased for artificial ascites. There was no difference in complications between the fluid group and controls.
CONCLUSION: Intraperitoneal fluid administration is a safe and effective method of protecting non-target structures during percutaneous hepatic microwave ablation. While hydrodisplacement for bowel protection allows more aggressive case selection, these cases were associated with higher rates of local tumour progression.

Entities:  

Keywords:  Clinical trials – thermal ablation; radiofrequency/microwave; thermal ablation

Mesh:

Year:  2014        PMID: 25144819      PMCID: PMC6545596          DOI: 10.3109/02656736.2014.936050

Source DB:  PubMed          Journal:  Int J Hyperthermia        ISSN: 0265-6736            Impact factor:   3.914


  11 in total

Review 1.  Antenna Designs for Microwave Tissue Ablation.

Authors:  Hojjatollah Fallahi; Punit Prakash
Journal:  Crit Rev Biomed Eng       Date:  2018

2.  US-guided microwave ablation for primary hyperparathyroidism: a safety and efficacy study.

Authors:  Bo-Qiang Fan; Xiao-Wei He; Huan-Huan Chen; Wei-Ming Zhang; Wei Tang
Journal:  Eur Radiol       Date:  2019-03-19       Impact factor: 5.315

Review 3.  Microwave ablation in primary and secondary liver tumours: technical and clinical approaches.

Authors:  Maria Franca Meloni; Jason Chiang; Paul F Laeseke; Christoph F Dietrich; Angela Sannino; Marco Solbiati; Elisabetta Nocerino; Christopher L Brace; Fred T Lee
Journal:  Int J Hyperthermia       Date:  2016-08-02       Impact factor: 3.914

Review 4.  Complications from percutaneous microwave ablation of liver tumours: a pictorial review.

Authors:  Cheng Fang; Kelvin Cortis; Gibran T Yusuf; Stephen Gregory; Dylan Lewis; Pauline Kane; Praveen Peddu
Journal:  Br J Radiol       Date:  2019-05-13       Impact factor: 3.039

Review 5.  Artificial ascites is feasible and effective for difficult-to-ablate hepatocellular carcinoma.

Authors:  Chia-Chi Wang; Jia-Horng Kao
Journal:  Hepatol Int       Date:  2015-06-25       Impact factor: 6.047

6.  Cryotherapy for liver metastases.

Authors:  Malgorzata M Bala; Robert P Riemsma; Robert Wolff; Michal Pedziwiatr; Jerzy W Mitus; Dawid Storman; Mateusz J Swierz; Jos Kleijnen
Journal:  Cochrane Database Syst Rev       Date:  2019-07-10

7.  Intravoxel Incoherent Motion Diffusion Weighted MR Imaging for Monitoring the Instantly Therapeutic Efficacy of Radiofrequency Ablation in Rabbit VX2 Tumors without Evident Links between Conventional Perfusion Weighted Images.

Authors:  Ziyi Guo; Qiang Zhang; Xiaoguang Li; Zhengyu Jing
Journal:  PLoS One       Date:  2015-05-28       Impact factor: 3.240

8.  Thermochemical ablation therapy of VX2 tumor using a permeable oil-packed liquid alkali metal.

Authors:  Ziyi Guo; Qiang Zhang; Xiaoguang Li; Zhengyu Jing
Journal:  PLoS One       Date:  2015-04-17       Impact factor: 3.240

9.  A preoperative mathematic model for computed tomographic guided microwave ablation treatment of hepatic dome tumors.

Authors:  Fei Gao; Guo-Bao Wang; Zhan-Wang Xiang; Bin Yang; Jing-Bing Xue; Zhi-Qiang Mo; Zhi-Hui Zhong; Tao Zhang; Fu-Jun Zhang; Wei-Jun Fan
Journal:  Oncotarget       Date:  2016-05-03

10.  Clinical Application of Artificial Ascites in assisting CT-guided Percutaneous Cryoablation of Hepatic Tumors Adjacent to the Gastrointestinal Tract.

Authors:  Bing Li; Chuan Liu; Xiao-Xue Xu; Yang Li; Yong Du; Chuan Zhang; Hou-Jun Zheng; Han-Feng Yang
Journal:  Sci Rep       Date:  2017-11-30       Impact factor: 4.379

View more