Literature DB >> 25144810

Active dynamic infrared thermal imaging in burn depth evaluation.

Alicja Renkielska1, Mariusz Kaczmarek, Antoni Nowakowski, Jacek Grudziński, Piotr Czapiewski, Andrzej Krajewski, Irena Grobelny.   

Abstract

The aim of this study was to find the relationship between active dynamic thermography (ADT) with cold excitation and burn depth. This new modality of evaluation of burns seems to be an attractive proposal for quantitative classification, allowing proper choice of burn wound treatment: conservative or surgical, especially compared with static thermography. The work was an in vivo experiment on domestic pigs, and a small number of patients were also diagnosed as part of the study. Statistical analysis showed a high correlation between the ADT synthetic parameter--thermal time constant, τ--and the classification of burn wounds that were predicted to heal within 3 weeks and so were treated conservatively and those that were predicted to not heal within 3 weeks and so were surgically treated. The results of the study show an accuracy of 60.7% for clinical evaluation, 69.6% for static thermography, 83.0% for ADT, and 84.0% for histopathologic assessment. The authors have concluded that the ADT method with cold excitation is suitable for the qualitative and quantitative assessment of burn depth.

Entities:  

Mesh:

Year:  2014        PMID: 25144810     DOI: 10.1097/BCR.0000000000000059

Source DB:  PubMed          Journal:  J Burn Care Res        ISSN: 1559-047X            Impact factor:   1.845


  8 in total

1.  Early Assessment of Burn Depth with Far Infrared Time-Lapse Thermography.

Authors:  Jon D Simmons; Steven A Kahn; Adrienne L Vickers; Edward S Crockett; Jonathon D Whitehead; Amy K Krecker; Yann-Leei Lee; Adam N Miller; Scott B Patterson; William O Richards; Wiltz W Wagner
Journal:  J Am Coll Surg       Date:  2018-01-31       Impact factor: 6.113

2.  Active thermodynamic contrast imaging for label-free tumor detection in a murine xenograft tumor model.

Authors:  Gyungseok Oh; Kyung-Hwa Lee; Euiheon Chung
Journal:  Biomed Opt Express       Date:  2017-10-16       Impact factor: 3.732

3.  Hyperspectral index-based metric for burn depth assessment.

Authors:  Sorin Viorel Parasca; Mihaela Antonina Calin; Dragos Manea; Sorin Miclos; Roxana Savastru
Journal:  Biomed Opt Express       Date:  2018-10-26       Impact factor: 3.732

Review 4.  Imaging in Chronic Wound Diagnostics.

Authors:  Shuxin Li; Ali H Mohamedi; Jon Senkowsky; Ashwin Nair; Liping Tang
Journal:  Adv Wound Care (New Rochelle)       Date:  2020-03-19       Impact factor: 4.730

Review 5.  Cutaneous and local radiation injuries.

Authors:  Carol J Iddins; Andrea L DiCarlo; Mark D Ervin; Eduardo Herrera-Reyes; Ronald E Goans
Journal:  J Radiol Prot       Date:  2022-01-12       Impact factor: 1.559

6.  Infantile hemangioma status by dynamic infrared thermography: A preliminary study.

Authors:  Shoná A Burkes; Manish Patel; Denise M Adams; Adrienne M Hammill; Kenneth P Eaton; R Randall Wickett; Marty O Visscher
Journal:  Int J Dermatol       Date:  2016-04-08       Impact factor: 2.736

7.  Best practices for standardized performance testing of infrared thermographs intended for fever screening.

Authors:  Pejman Ghassemi; T Joshua Pfefer; Jon P Casamento; Rob Simpson; Quanzeng Wang
Journal:  PLoS One       Date:  2018-09-19       Impact factor: 3.240

8.  Development and validation of an algorithm to predict the treatment modality of burn wounds using thermographic scans: Prospective cohort study.

Authors:  Mario Aurelio Martínez-Jiménez; Jose Luis Ramirez-GarciaLuna; Eleazar Samuel Kolosovas-Machuca; Justin Drager; Francisco Javier González
Journal:  PLoS One       Date:  2018-11-14       Impact factor: 3.240

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.