| Literature DB >> 25144638 |
Huping Wu1, Yuqian Wang1, Nuo Dong1, Fan Yang1, Zhirong Lin1, Xumin Shang1, Cheng Li1.
Abstract
OBJECTIVE: To explore meibomian gland dysfunction (MGD) may determine the severity of dry eye conditions in visual display terminal (VDT) workers.Entities:
Mesh:
Year: 2014 PMID: 25144638 PMCID: PMC4140788 DOI: 10.1371/journal.pone.0105575
Source DB: PubMed Journal: PLoS One ISSN: 1932-6203 Impact factor: 3.240
Patient Information and Tear Parameters in the Long and Short Time VDT Workers.
| Parameters | Short time VDT (n = 80) | Long time VDT (n = 106) |
|
| Age (yr) | 30.58±5.83 (23–52) | 31.79±5.53 (20–47) | 0.053 |
| Sex ratio (male/female) | 22/18 | 22/31 | 0.197 |
| VDT working time (h/day) | 3.20±0.88 (1–4) | 8.31±2.31 (5–14) | <0.0001 |
| VDT working years | 5.25±2.85 (1–10) | 7.91±3.81 (2–17) | <0.001 |
| OSDI | 29.23±10.98 | 37.38±18.23 | <0.01 |
| BUT (s) | 6.71±2.66 | 4.92±2.41 | <0.001 |
| fluorescein score | 1.46±1.67 | 3.73±2.98 | <0.0001 |
| Schirmer (mm) | 12.88±9.66 | 11.53±8.32 | 0.554 |
Note: Data presented as Mean ± SD (ranges) of Values; n = number of eye; No statistic difference in tear production by Schirmer test between 2 groups (P = 0.554).
Incidences of Meibomian Gland Parameters in the Long and Short Time VDT Workers.
| Short time VDT (n = 80) | Long Time VDT (n = 106) | |
|
| ||
| 0 | 35 (43.75%) | 5 (4.72%) |
| 1 | 35 (43.75%) | 53 (50%) |
| 2 | 8 (10%) | 42 (39.62%) |
| 3 | 2 (2.50%) | 6 (5.66%) |
| 4 | 0 (0%) | 0 (0%) |
|
| ||
| 0 | 24 (30%) | 15 (14.15%) |
| 1 | 56 (70%) | 49 (46.23%) |
| 2 | 0 (0%) | 42 (39.62%) |
| 3 | 0 (0%) | 0 (0%) |
|
| ||
| 0 | 13 (16.25%) | 4 (3.77%) |
| 1 | 26 (32.50%) | 19 (17.93%) |
| 2 | 38 (47.50%) | 40 (37.74%) |
| 3 | 3 (3.75%) | 29 (27.36%) |
| 4 | 0 (0%) | 10 (9.43%) |
| 5 | 0 (0%) | 4 (3.77%) |
| 6 | 0 (0%) | 0 (0%) |
Note: Data presented as case number (percentage).
Figure 1The Detailed Distributions of Each Meibomian Gland Parameter in the two groups of VDT Workers.
Data presented as percentage (case number).
Comparison of Meibomian Gland Parameters in the Long and Short time VDT Groups.
| Parameters | Short time VDT (n = 80) | Long time VDT (n = 106) |
|
| Lid margin abnormality score | 0.71±0.75 | 1.46±0.68 | <0.0001 |
| Meibum score | 0.78±0.67 | 1.25±0.69 | <0.0001 |
| Meiboscore | 1.39±0.80 | 2.32±1.11 | <0.0001 |
Note: Data presented as Mean ± SD of Values.
Figure 2Representative images of fluorescein staining (Fluorescein), lid margin and meibography of upper lid and lower lid in patients from long or short time VDT groups.
The score of each image is noted at bottom left. The upper panel shows normal eyes with score 0; the middle panel shows eyes from short time VDT group: the right eye from a 23-year-old female, VDT working time: 3 h/d; OSDI: 31.25; BUT: 10 s; Schirmer test: 15 mm; meibum score were 1. The bottom panel shown eyes from long time VDT group: the left eye from a 22-year-old female, VDT working time: 8 h/d; OSDI: 60; BUT: 4 s; Schirmer test: 15 mm; the meibum score was 2. Corneal fluorescein staining is noted by yellow arrows. Vascular engorgement is outlined by red arrow and plugged meibomian gland orifice is outlined by white arrow. The areas of meibomian gland dropout are encircled with dotted white lines.
The Comparison of Tear and Meibomian Gland Parameters in the Long Time VDT Workers with Low or Normal Tear Volumes.
| Parameters | Schirmer Test (<10 mm, n = 52) | Schirmer Test (>/ = 10 mm, n = 54) |
|
| Schirmer (mm) | 4.89±1.98 | 17.93±6.95 | <0.0001 |
| VDT working time (h/d) | 8.11±2.37 | 8.51±2.26 | 0.407 |
| OSDI | 37.92±18.27 | 36.87±18.34 | 0.676 |
| BUT (s) | 4.73±1.78 | 5.11±2.89 | 0.86 |
| Fluorescein score | 3.67±2.87 | 3.78±3.11 | 0.995 |
| Lid margin abnormality score | 1.37±0.63 | 1.56±0.72 | 0.114 |
| Meibum score | 1.37±0.66 | 1.15±0.71 | 0.112 |
| Meiboscore | 2.23±1.15 | 2.41±1.07 | 0.301 |
Note: Data presented as Mean ± SD of Values.
Figure 3Representative images of fluorescein staining, lid margin and meibography in patients with or without tear volume deficiency in long time VDT group.
The score of each image is noted at bottom left. The upper panel shows eyes from low tear volume subgroup: the right eye from a 29-year-old male, VDT work time: 12 h/d; OSDI: 54.55; BUT: 7 s; Schirmer test: 5 mm; the meibum score was 2. The bottom panel shows eyes from normal tear volume subgroup: the right eye from a 37-year-old male, VDT work time: 6 h/d; OSDI: 40.00; BUT: 5 s; Schirmer test: 17 mm; the meibum score was 1. Corneal fluorescein staining is noted by yellow arrows. Vascular engorgement is outlined by red arrow and plugged meibomian gland orifice is outlined by white arrow. The areas of meibomian gland dropout are encircled with dotted white lines.
Simple correlation analysis of 3 Meibomian Gland Dysfunction scores with dry eye parameters in Visual Display Terminal workers.
| Lid margin score | Meibum score | Meiboscore | ||||
|
|
|
|
|
|
| |
| VDT working time (h/day) | 0.450 | <0.0001 | 0.318 | <0.0001 | 0.365 | <0.0001 |
| OSDI | 0.178 | 0.015 | 0.052 | 0.484 | −0.088 | 0.235 |
| Fluorescein score | 0.289 | <0.0001 | 0.402 | <0.0001 | 0.373 | <0.0001 |
| BUT (s) | −0.299 | <0.0001 | −0.302 | <0.0001 | −0.202 | 0.02 |
| Schirmer (mm) | 0.013 | 0.865 | −0.021 | 0.776 | 0.004 | 0.956 |
Note: R, correlation value by Spearman correlation analysis; P, significance level in Spearman correlation analysis.