Literature DB >> 25142382

Reproducibility of microvascular vessel density analysis in Sidestream dark-field-derived images of healthy term newborns.

Victor J van den Berg1, Hugo A van Elteren, Erik A B Buijs, Can Ince, Dick Tibboel, Irwin K M Reiss, Rogier C J de Jonge.   

Abstract

OBJECTIVE: Microcirculatory visualization has already been used to investigate buccal and cutaneous microcirculatory alterations in neonates. Still, the reproducibility of these microvascular measurements has never been studied in (premature) neonates. This study aimed to determine the reproducibility of microvascular vessel density in cutaneous and buccal SDF clips in one-day-old term newborns.
METHODS: Buccal and cutaneous microcirculations were measured using SDF imaging. Vessel density was independently assessed by two investigators. Reproducibility was assessed from the ICC and Bland-Altman analysis.
RESULTS: Reproducibility of vessel density assessment in the buccal area was good, with ICCs for total and PVD of 0.93 (0.88-0.97) and 0.93 (95% CI 0.85-0.97), respectively, and a near zero bias and acceptable limits of agreement in the Bland-Altman analysis. Reproducibility of assessment of the cutaneous microcirculation was poor with ICCs for total and PVD of 0.31 (0-0.70) and 0.37 (0-0.74), respectively, and large biases (3.09 and 2.53) in the Bland-Altman analysis.
CONCLUSIONS: Evaluation of buccal microvascular vessel density in SDF-derived images in term newborns is reproducible in contrary to the cutaneous vessel density.
© 2014 John Wiley & Sons Ltd.

Entities:  

Keywords:  Sidestream dark field; buccal; cutaneous; neonates; reproducibility

Mesh:

Year:  2015        PMID: 25142382     DOI: 10.1111/micc.12163

Source DB:  PubMed          Journal:  Microcirculation        ISSN: 1073-9688            Impact factor:   2.628


  7 in total

1.  Pregnancy at high altitude in the Andes leads to increased total vessel density in healthy newborns.

Authors:  Norina N Gassmann; Hugo A van Elteren; Tom G Goos; Claudia R Morales; Maria Rivera-Ch; Daniel S Martin; Patricia Cabala Peralta; Agustin Passano Del Carpio; Saul Aranibar Machaca; Luis Huicho; Irwin K M Reiss; Max Gassmann; Rogier C J de Jonge
Journal:  J Appl Physiol (1985)       Date:  2016-07-21

2.  Transcutaneous Microcirculatory Imaging in Preterm Neonates.

Authors:  Hugo van Elteren; Irwin K M Reiss; Rogier C J de Jonge
Journal:  J Vis Exp       Date:  2015-12-31       Impact factor: 1.355

3.  Second consensus on the assessment of sublingual microcirculation in critically ill patients: results from a task force of the European Society of Intensive Care Medicine.

Authors:  Can Ince; E Christiaan Boerma; Maurizio Cecconi; Daniel De Backer; Nathan I Shapiro; Jacques Duranteau; Michael R Pinsky; Antonio Artigas; Jean-Louis Teboul; Irwin K M Reiss; Cesar Aldecoa; Sam D Hutchings; Abele Donati; Marco Maggiorini; Fabio S Taccone; Glenn Hernandez; Didier Payen; Dick Tibboel; Daniel S Martin; Alexander Zarbock; Xavier Monnet; Arnaldo Dubin; Jan Bakker; Jean-Louis Vincent; Thomas W L Scheeren
Journal:  Intensive Care Med       Date:  2018-02-06       Impact factor: 17.440

Review 4.  Regulation of blood flow and volume exchange across the microcirculation.

Authors:  Matthias Jacob; Daniel Chappell; Bernhard F Becker
Journal:  Crit Care       Date:  2016-10-21       Impact factor: 9.097

Review 5.  The vulnerable microcirculation in the critically ill pediatric patient.

Authors:  J W Kuiper; D Tibboel; C Ince
Journal:  Crit Care       Date:  2016-10-30       Impact factor: 9.097

6.  Videomicroscopy as a tool for investigation of the microcirculation in the newborn.

Authors:  Ian M R Wright; Joanna L Latter; Rebecca M Dyson; Chris R Levi; Vicki L Clifton
Journal:  Physiol Rep       Date:  2016-10

7.  Role of Combining Peripheral with Sublingual Perfusion on Evaluating Microcirculation and Predicting Prognosis in Patients with Septic Shock.

Authors:  Pan Pan; Da-Wei Liu; Long-Xiang Su; Huai-Wu He; Xiao-Ting Wang; Chao Yu
Journal:  Chin Med J (Engl)       Date:  2018-05-20       Impact factor: 2.628

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.