C C Chen1, M W Chang2, C P Chang3, S C Chan1, W Y Chang1, C L Yang1, M T Lin4. 1. Department of Electrical Engineering, National Cheng-Kung University, Tainan, Taiwan. 2. Department of Electrical Engineering, Southern Taiwan University of Science and Technology, Tainan, Taiwan. 3. Department of Biotechnology, Southern Taiwan University of Science and Technology, Tainan, Taiwan. 4. Department of Medical Research, Chi Mei Medical Center, Tainan, Taiwan.
Abstract
We developed a forced non-electric-shock running wheel (FNESRW) system that provides rats with high-intensity exercise training using automatic exercise training patterns that are controlled by a microcontroller. The proposed system successfully makes a breakthrough in the traditional motorized running wheel to allow rats to perform high-intensity training and to enable comparisons with the treadmill at the same exercise intensity without any electric shock. A polyvinyl chloride runway with a rough rubber surface was coated on the periphery of the wheel so as to permit automatic acceleration training, and which allowed the rats to run consistently at high speeds (30 m/min for 1 h). An animal ischemic stroke model was used to validate the proposed system. FNESRW, treadmill, control, and sham groups were studied. The FNESRW and treadmill groups underwent 3 weeks of endurance running training. After 3 weeks, the experiments of middle cerebral artery occlusion, the modified neurological severity score (mNSS), an inclined plane test, and triphenyltetrazolium chloride were performed to evaluate the effectiveness of the proposed platform. The proposed platform showed that enhancement of motor function, mNSS, and infarct volumes was significantly stronger in the FNESRW group than the control group (P<0.05) and similar to the treadmill group. The experimental data demonstrated that the proposed platform can be applied to test the benefit of exercise-preconditioning-induced neuroprotection using the animal stroke model. Additional advantages of the FNESRW system include stand-alone capability, independence of subjective human adjustment, and ease of use.
We developed a forced non-electric-shock running wheel (FNESRW) system that provides rats with high-intensity exercise training using automatic exercise training patterns that are controlled by a microcontroller. The proposed system successfully makes a breakthrough in the traditional motorized running wheel to allow rats to perform high-intensity training and to enable comparisons with the treadmill at the same exercise intensity without any electric shock. A polyvinyl chloride runway with a rough rubber surface was coated on the periphery of the wheel so as to permit automatic acceleration training, and which allowed the rats to run consistently at high speeds (30 m/min for 1 h). An animal ischemic stroke model was used to validate the proposed system. FNESRW, treadmill, control, and sham groups were studied. The FNESRW and treadmill groups underwent 3 weeks of endurance running training. After 3 weeks, the experiments of middle cerebral artery occlusion, the modified neurological severity score (mNSS), an inclined plane test, and triphenyltetrazolium chloride were performed to evaluate the effectiveness of the proposed platform. The proposed platform showed that enhancement of motor function, mNSS, and infarct volumes was significantly stronger in the FNESRW group than the control group (P<0.05) and similar to the treadmill group. The experimental data demonstrated that the proposed platform can be applied to test the benefit of exercise-preconditioning-induced neuroprotection using the animal stroke model. Additional advantages of the FNESRW system include stand-alone capability, independence of subjective human adjustment, and ease of use.
Regular exercise is considered to be beneficial for the overall health of an organism in
its normal and diseased states (1-3). An increasing number of studies have shown the
beneficial effects of exercise on stroke-induced brain injuries in animal models (4,5). The
neuroprotective mechanisms of exercise in humans are the same as those in animals;
therefore, animal injury models are used to verify the efficacy of exercise in humans
(6-9).
Rats are often used in these experiments. Six weeks of free-running wheel exercise
enhances the survival of neural progenitor cells after a hemorrhagic stroke (6), and pretraining exercises on a free-running
wheel for 7 weeks can stimulate neurogenesis in damaged neuronal cells (7). Additionally, 2 or 4 weeks of pretraining
exercise on a treadmill reduces brain damage after ischemic stroke (8). Research has shown an exercise preconditioning
benefit on neurological deficits and the infarct volume in rats that exercised on a
treadmill at 15 m/min for 30 min/day for 3 weeks and were then subjected to transient
middle cerebral artery occlusion (MCAo) (9).
However, more animal experiments used 20-30 m/min as exercise preconditioning for the
prevention of stroke than low-intensity training (15 m/min) (4,10-13). These findings suggest that exercise preconditioning can
produce neuroprotection from ischemic stroke and that this protection is manifested
during reperfusion. In this study, an animal ischemic stroke model was triggered to
validate the proposed system.Animal locomotion platforms can be classified into voluntary running wheel and forced
treadmill groups (14). The treadmill uses
electric shock to force rats to run, whereas the running wheel allows voluntary running.
Voluntary running is used to simulate daily human activities (1). In contrast, rats on a treadmill are forced to move for 0.5-1 h
for 5-7 days per week, which simulates an athlete performing long-term exercise in a gym
(15). Clinical anatomical experiments have
found that these two types of exercise can enhance and maintain the energizing brain
glucose transporter (GLUT-1 and GLUT-3) (16).
Forced and voluntary exercise differentially affect neurophysiological performance
(17,18). Forced exercise effectively induces neuroprotection in stroke, but this is
not the case with voluntary exercise (17).
However, the voluntary activity leads to more prominent plastic changes in the
hippocampal formation of rats than the forced exercise (18). The ability to control and maintain a high training intensity (>20
m/min) is a major advantage of a treadmill. The disadvantages of a voluntary running
wheel include a substantially lower intensity of exercise and more variation in the
amount of exercise that each animal receives. However, two methods interfere with the
experimental results from forced treadmills: 1) aversive electric
shocks to force exercise training, and 2) manually adjusting the speed
of the exercise training at the beginning of the exercise and during the training stage.
In the anatomical experimental data, when training with electric shocks, it is difficult
to distinguish whether psychological stress or exercise training induces a physiological
phenomenon. In addition, psychological stress may have negative effects, including
adrenal hypertrophy, splenic atrophy, and increased circulating corticosterone (9,17,19). These extra physiological responses interfere
with the experimental results. Therefore, this study proposes a forced
non-electric-shock running wheel (FNESRW) exercise platform to train animals maintaining
high-intensive training and to minimize the influence of psychological stress. Moreover,
an automated exercise-training model is included to accurately control the amount of
exercise activity and to reduce the disadvantages of manual training on treadmills.Motorized running wheels (MRWs) are commercially available for researchers (20-22).
However, Leasure and Jones (20) found that rats
were reluctant to run at speeds higher than 20 m/min on the currently available MRWs.
These MRWs are currently used in research for low-speed running (20-23), and the lack of
smooth automation training patterns allows rats to fall and become injured during
high-intensity training. High-intensity exercise training (>20 m/min) triggers
effective neurophysiological protection and recovery in a more effective and faster
manner than low-intensity training for some clinical end-points (24-27). Therefore, this study
sought to overcome the difficulties of high-intensity exercise training on a traditional
MRW and excluded the interference effects of the treadmill with electric shock that is
applied to an animal model. We developed an automatic and progressive exercise training
pattern that spans from preparatory training to official exercise running, prevents
injuries, and removes the disadvantages of a human operator. Moreover, a polyvinyl
chloride (PVC) runway with a rough rubber surface was coated onto the periphery of the
wheel to allow the rats to run smoothly and consistently at high speeds (30 m/min for 1
h). The firmware of the system can be easily modified to suit movement patterns for
other applications. We describe a fully functional prototype of the system and its
implementation. The results of this study show that the infarction volume can be reduced
through preconditioning exercise with the proposed platform.
Material and Methods
The proposed FNESRW with an automatic training function can train animals to perform
high-intensity running while avoiding the use of electric shocks, which allows the
impact of exercise on the infarct volume in cerebral ischemic stroke to be verified
without interference. The animals used in the experiment were randomly assigned to four
groups (FNESRW, treadmill, sham, and control). Only the FNESRW and treadmill groups
followed a 3-week exercise training program (Figure
1). Exercise speed training data from the 3-day preparatory training were
acquired using the manual mode of the proposed running wheel exercise platform, which
was used to construct a complete set of automatic exercise training models for the
subsequent 3 weeks of exercise. After the 3 weeks of exercise, a stroke was induced in
the FNESRW, treadmill, and control animals with 60 min of MCAo, which was followed by
7-day reperfusion using an intraluminal filament. The same surgery was performed for the
sham group but without triggering blocked arteries. To evaluate the damage and recovery
from the stroke, an inclined plane device test (28) and the modified neurological severity score (mNSS) (29) were used to evaluate neurological damage for
the next 7 days. Finally, the animals were killed by exposure to triphenyltetrazolium
chloride (TTC) to assess infarct volume.
Figure 1
Timeline of the experimental design. Only the forced non-electric-shock
running wheel (FNESRW) and treadmill groups followed 3 weeks of running training,
and only the sham group was not triggered by middle cerebral artery occlusion
(MCAo). All animals were observed for 7 days using a behavior test.
FNESRW
The proposed microcontroller-based FNESRW system facilitates exercise preconditioning
for small laboratory animals such as rats. The FNESRW system consists of four parts:
1) a roller platform coated with a PVC runway - the sides of the
center axis of the wheel are welded to the triangular metal framework to support the
commercially available roller that is constructed of metal bars, and the bearing is
embedded in the center of the wheel to enable free rotation and create a voluntary
running wheel configuration; 2) a high-torque, brushless direct
current (DC) motor, which drives the roller - a hexagonal screw latches to a gear
into the central axis of the motor and wheel, and the gears on the motor and the
wheel are the same size, and these two gears are mutually engaged and can be removed
(Figure 2) to create a forced running wheel
configuration; 3) a flexible microcontroller is used to precisely
control the motor speed by using pulse-width modulation (PWM) for the automatic
progressive training function; and 4) a conventional computer with a
parallel port is used to connect the system to a computer, which writes and loads the
firmware that is used in the microcontroller and controls the speed of the FNESRW
system.
Figure 2
Center axis of the motor and roller are embedded by gears. A hexagonal
screw is used to fasten the assembly.
A photograph of the lab-built apparatus is shown in Figure 3. The running platform has a wheel that is 35 cm in diameter and
15 cm wide, and the height from the triangle bracket to the bottom of the wheel is 20
cm. The outer ring of the wheel is coated with a PVC runway with a rough surface,
which is tightly fixed to the outside of the wheel frame with strong Velcro tape,
making it removable. Most rats fail to run up and do not fully step on the bars at 20
m/min on the running wheel without the PVC runway (the structure of the commercially
available running wheel). This design is effective for overcoming the high-intensity
training restrictions of commercially available MRWs, thus allowing rats to run
relatively stably and preventing injuries at high speeds (20 m/min or more). Eleven
sensing plates were placed on the wheel rim to detect rotation speed (Figure 3).
Figure 3
Forced non-electric-shock running wheel (FNESRW).
The speed of the FNESRW is controlled by a DC motor and its driver. The system can be
switched between manual and automatic modes using a jumper switch. The manual mode
employs a variable resistor to produce various voltages and the control speed,
whereas the automatic mode is controlled by the microcontroller firmware with PWM.
Six automatic training speed patterns exist: three for preparatory training and three
for formal training.A block diagram of the control unit hardware is shown in Figure 4. The control unit consists of a microcontroller, a
liquid-crystal display (LCD), a touch-button keypad, an in-system programing
interface, a velocity monitor, a velocity control, a jumper switch, and a power
supply (a brief description of each component is provided below).
Figure 4
Block diagram of the microcontroller-based control unit. IC: integrated
circuit.
Microcontroller
The system is based on an AT89S52 microcontroller (ATMEL Corp., USA) that provides
a highly flexible and cost-effective solution for embedded control applications.
The AT89S52 includes four programmable ports, two external interrupt sources,
three timers or counters, one programmable serial USART, 8 kB of program memory,
and 256 B of RAM for data.
Display
A conventional LCD with 2×10 characters shows the rotation speed of the proposed
running wheel to the local user. The driver and built-in backlight are included
with this off-the-shelf LCD module.
Keypad
A 4×4 button switch is used for the user interface. The six buttons were assigned
three commands each for preparatory and formal trainings. Therefore, the user can
input commands that trigger the automatic training pattern. These instructions can
also be input using the keyboard of an attached PC.
Velocity monitor
The rotation of the proposed running wheel was detected using 11 sensing plates
and a transmissive optical sensor (TCRT2103, Vishay Semiconductors, USA). A
velocity-monitoring circuit was designed to process the received signals, which
were sent to the microcontroller for speed calculation before display.
Velocity control
The speed control was set to manual or automatic mode using a jumper switch. The
automatic mode provided a consistent and precise procedure for training rats and
eliminated the human factor. The manual mode allowed the training to be
dynamically controlled by a variable resistor (potentiometer). The automatic mode
contained six training models that were triggered by the six buttons. The velocity
control function of automatic training was achieved using a microcontroller
(AT89S52), a bridge integrated circuit (IC; TA7257P, Toshiba, Japan), a motor
driver (BLED12A, Oriental Motor, Japan), and a DC motor (BLEM512-GFS, Oriental
Motor). The motor torque was 8.6 N·m, and it effectively drove the running wheel
platform (approximately 1 kg) in addition to the weight of an experimental rat
(250 to 350 g) with a sufficient margin for an instant reaction to the force that
was created by a running rat. The pulse signal of the microcontroller generated a
specific voltage through the bridge IC, which was used to control the motor
driver. The bridge IC was a full-bridge driver that converted the logic input
signal into an analog signal.
Power supply
A conventional linear power supply provided regulated DC voltage (+5 V) for all
components of the system, except for the DC motor driver and DC motor, which were
directly powered from the main city power.
Automatic training model construction
The progressive training model was constructed to allow the rats to run steadily and
continuously at 30 m/min for 1 h. Because of the curved structure of the running
wheel, it was more difficult for the rats to be trained to run quickly and smoothly
at high speeds (20 m/min or more) compared with training on a traditional treadmill.
When accelerating, rats could easily fall and become injured. Some rats could jump
from high to low positions, and such running behavior was relatively more labor
saving than the linear motion of the treadmill. Therefore, an automatic progressive
exercise-training model was designed to enable the animals to smoothly accelerate
from 0 to 30 m/min and prevent the skipping of parts of the exercise on rollers. The
acceleration curve was systematically established and repeated daily to remove human
error. In this study, a manual, progressive training method was used to train the
rats to reach and maintain 20 m/min within 3 days. Animal movement experiments
usually use a preparatory training period of 3 days to allow the rats to adapt and
learn the 20 m/min running training (4,10,30).
The rats are injured easily when running at speeds of 20 m/min without the adaptive
learning stage. Nine rats were used in the experiments to construct training patterns
for 3 days (30 min/day) using the manual mode. The training data of the velocity for
various times are shown in Table 1.
Automatic animal training patterns were constructed for rats without prior running
wheel experience, and they learned to run at 20 m/min (a medium-intensity exercise)
within 3 days. Progressive acceleration was used to train the rats. The speed was
temporarily reduced when a rat fell, and was raised when a rat ran steadily. The
training speed was steadily increased, until the maximum speed that the rat could
maintain while running smoothly was determined. On Day 1, the average maximum speed
was approximately 13 m/min. The acceleration slope was gradually raised on Day 2, and
it was increasingly accelerated on Day 3 to achieve the desired maximum average speed
of approximately 20 m/min. The rats reached higher speeds more quickly as they
familiarized themselves with the running wheel. The daily maximum steady velocity
showed an upward trend.The accelerative curve showed a similar exponential distribution for the actual
experimental training velocity data. Therefore, in this study, an exponential
exercise acceleration training curve for 3 days was constructed (Figure 5), where the x-axis is time and the y-axis is the
corresponding controlled velocity. The velocity at time t
iswhere A and B are constants and τ is the time constant. After fitting
the experimental data for the first day into the training model, A was set to 5 and B
was set to 8. The acceleration slope of the velocity was obtained by changing the
time constant τ. Parameter construction of the training model for the other days
followed the same method. The maximum training speed of the second week in the study
was increased to 30 m/min based on the exponential accelerative training model. The
microcontroller firmware was programmed to change the output of PWM and to control
the speed of the DC motor through the bridge IC.
Figure 5
Construction of the three exponential exercise acceleration training
model.
Software
Speed control and speed detection software were developed for the FNESRW system.
First, the speed control software facilitated accurate and smooth acceleration
control during the initial 3 days of preparatory training and 3 weeks of formal
training. The goal of the 3-day preparatory training was to familiarize the rats with
the roller and condition them to run smoothly at 20 m/min. The manual training data
were analyzed to extract the speed-controllable parameters for an automated
exponential training speed curve by PWM control. Second, speed detection software
facilitated the recording of distance information using the microcontroller external
interrupt (external INT0) service routine. The external INT0 was triggered using the
transmissive optical sensor to import data from the 11 sensing plates. Instantaneous
speed was derived by dividing by the time and was displayed on the LCD.The microcontroller firmware was written in the C programming language and included
the main program, two timer-interrupt service routines, and one external-interrupt
service routine. The main program consisted of a loop that calculated and displayed
the training speed (Figure S1). The global variable “Num_Sensing” was the sensed
number of the transmissive optical sensors; Num_Sensing was incremented as one unit
per 10-cm rotation, and the global variable “Time_0” was a second counter. Therefore,
rotational speed was obtained as speed=Num_Sensing×10/Time_0. The speed was displayed
on the LCD, and the main program awaited commands from the local keypad. Commands A
through C were the preparatory training speed curves for the first, second, and third
days, respectively. After IN0, Timer 0, and Timer 1 were enabled, a speed table of
the training curve for the first to third days was created based on Equation 1. A PWM
value was generated every 10 s according to the table that was created during the
training period. Commands D through F corresponded to the first, second, and third
weeks of the formal training curve, with maximum speeds and durations of 20 m/min for
30 min, 30 m/min for 30 min, and 30 m/min for 60 min, respectively. Two
timer-interrupt service routines were used: Timer 0 and Timer 1 (Figure S2A and B,
respectively). Timer 0 was used to calculate the time (in seconds) of a wheel
rotation. Timer 1 was used to generate the corresponding PWM value for the time unit,
which was used to update the PWM value every 10 s until the end of the exercise
(Exer_Time).One external-interrupt service routine, INT0, was in edge-trigger mode for the
transmissive sensing signal during wheel rotation (Figure S2C). The interrupt signal
was triggered by the sensing action of the transmissive optical sensor, the interval
between the figure sensing plates was 10 cm, and running distance information was
recorded there.
Calibration
A working prototype was implemented for the purpose of this study. First, the
rotation speed was calibrated, and an accurate reference speed was measured using a
speedometer (OXP-2A, Oriental Motor) and compared to the speed monitor module for
verification (the speedometer is shown in Figure
6). The manual and automatic modes of the proposed system were used to
verify the speed of rotation and to compare the deviation between the speedometer and
the speed monitor module. Manual mode was verified by randomly setting the speed and
comparing the speedometer value to that of the speed monitor module. To verify
automatic mode, one of the six keys on the keypad was pressed, and the speed value of
the speedometer was compared to that of the speed monitor module. The speedometer
data were accessed using the microcontroller through the speed-out connection port of
the motor driver (BLED12A, Oriental Motor), which generated 600 pulse signals per
cycle. The resulting errors were in the range of ±0.1 m/min.
Figure 6
Speedometer used for speed calibration.
Experimental animals
Adult male Wistar rats (average weight 228±22 g) were obtained from BioLASCO Taiwan
Co., Ltd (Taiwan). The animals were housed in groups of four at an ambient
temperature of 21±1°C, with a 12:12-h light-dark cycle. Pellet rat chow and tapwater
were available ad libitum. All protocols were approved by the Animal
Ethics Committee of the Chi-Mei Medical Center (Tainan, Taiwan) in accordance with
the Guide for the Care and Use of Laboratory Animals of the National Institutes of
Health (USA) and the Guidelines of the Animal Welfare Act.
Exercise training protocol
Animals were randomly assigned to the FNESRW (n=9), treadmill (n=9), control (n=9),
or sham (n=9) groups. The animals in the preconditioning exercise group were placed
on the FNESRW and treadmill (Exer-6M Treadmill, Columbus Instruments, USA) for a
3-day preparatory training to reach the required, basic efficient exercise intensity
of 20 m/min for 30 min. The animals were then subjected to official endurance running
training 5 days a week for 3 weeks (running for 30 min at 20 m/min, 30 min at 30
m/min, and 60 min at 30 m/min at 1, 2, and 3 weeks of training, respectively). The
work rate of the rats on this training protocol was approximately 70-75% of their
maximal oxygen consumption (31), and the
ambient temperature was controlled at 25±1°C. Body weight and rectal temperature of
the rats were recorded before and after running. The animals in the control and sham
groups did not receive exercise training, but were allowed to run freely in their
cages for 3 weeks.
MCAo
An MCAo was induced in exercised and nonexercised animals after 3 weeks according to
the stroke model. Animals were anesthetized and maintained with 1%-3% halothane in
70% N2O and 30% O2 with a face mask. The rectal temperature
(colon temperature) was monitored throughout the surgical procedure and maintained at
36.5±0.5°C using a circulating heating pad. MCAo was induced with an intraluminal
filament model (32) and maintained for 60 min.
In brief, the left common carotid, internal carotid artery (ICA), and external
carotid artery (ECA) were exposed by surgical operation. A filament (a 4-0 nylon
suture with a blunted tip, 0.37 mm in diameter; Doccol Corporation, USA) that was
coated with poly-L-lysine was inserted into the right ECA. Next, the direction of the
suture was altered toward the ICA and gently advanced to occlude the MCAo.
Reperfusion was established by withdrawal of the filament under anesthesia at the end
of Day 7. The reliability and effectiveness of this model to induce stroke was
guaranteed using poly-L-lysine-coated intraluminal sutures, which yielded
consistently large infarcts and greatly reduced variation in the results between
different animals (33). Rats in the sham group
underwent the same ECA and ICA procedures without the MCAo.
mNSS
The mNSS was used to measure various aspects of neurological function. The mNSS test
is a composite of motor (muscle status and abnormal movement), sensory (visual,
tactile, and proprioceptive), reflex (pinna, corneal, and startle), and balance tests
(29). Neurological function is graded on a
scale of 0 to 18 (normal and healthy score: 0; maximum deficit score: 18), where one
point counts for the inability to perform the test or for the lack of a tested
reflex; thus, a higher score represents more severe injury. All rats were able to
perform the tests every day for 7 days after surgery.
Inclined plane test
The grab performance of all rats was evaluated using an inclined plane device that
was developed in our laboratory (28), on each
of the 7 days after surgery. The inclined plane test is a quantitative, objective,
and sensitive method for evaluating motor deficits after cerebral ischemia in rats.
It assesses the ability of the rat to prevent itself from falling over and determines
the endurance strength in the upper and lower limbs. The sliding apparatus had a
60×60 cm acrylic surface that could be inclined from 0° (horizontal) to 70°. The
floor of the enclosure was covered with hook-side Velcro fabric, which provided a
secure surface for the rat to grab and hold. Each rat was initially placed on a 25°
inclined plane in the area of the hook-side Velcro fabric. The lower limbs were
allowed to clutch the Velcro, and the upper limbs remained on the acrylic surface.
The angle of the inclined plane was then raised until the lower limbs detached from
the Velcro and the rat slid down. Once this occurred, the increase of the plane angle
was stopped, and the angle was recorded. The inclined plane test was conducted for
each rat once a day for 7 days.
TTC staining and quantitative analysis of infarct volume
After 7 days of behavioral evaluation, the infarct volume was analyzed. The rats were
deeply anesthetized with urethane (500 mg/mL, ip), and the brains
were carefully removed and dissected into coronal, 1-mm sections using a vibratome.
The fresh brain slices were immersed in a 2% solution of 2-, 3-, and 5-TTC in normal
saline at 37°C for 30 min. The total infarct area was multiplied by the thickness of
the brain sections to obtain the infarct volume. The areas of noninfarcted tissue
ipsilateral and contralateral to the occluded side were measured using a scanner and
an image analysis system (34). The
noninfarcted area in the ipsilateral hemisphere was subtracted from that in the
contralateral hemisphere, and the infarct volume was calculated using the following
formula: corrected percentage of infarct volume=(contralateral hemispheric volume
minus ipsilateral noninfarcted volume)/contralateral hemispheric volume (35).
Statistical analysis
Data are reported as means±SE. Based on the underlying assumption that the test data
of each group satisfy Gaussian distribution, a parametric analysis was applied to
compare the differences among the groups. Comparisons between the various groups were
evaluated using a one-way analysis of variance, followed by the Fisher
least-significant difference post hoc test. Pairwise comparison was
performed using the Student t-test in the case of heterogeneity of
variance of data. Data were analyzed using the Sigma Plot Software (USA), and, in all
cases, statistical significance was set at P<0.05.
Results
The mNSS was used to assess the effects of exercise preconditioning (FNESRW and
treadmill groups) on the improvement of damaged neurological function after stroke.
Figure 7 shows the average mNSS values of
the four groups for the 7 days after surgery (means±SD). Scores of the sham group
that were obtained before and after surgery were similar. The mNSS value in the
control group was the highest (with heavy to moderate damage; Figure 7A and B), and the mNSS values for the FNESRW group were
significantly lower (moderate to minor damage) than those of the control group (Figure 7B; P<0.05). These results indicated
that forced exercise preconditioning on the FNESRW was effective for stroke
prevention. Although average scores for the treadmill were lower than those for the
FNESRW, no significant difference was observed. Scores for the sham group were
significantly lower than those for the FNESRW and treadmill groups (Figure 7B; P<0.05), which indicated the similar
efficacy of nerve damage recovery over 7 days between the treadmill and FNESRW
groups.
Figure 7
Average modified neurological severity score (mNSS) for the three groups
over a period of 7 days. A, Daily average mNSS values.
B, Average mNSS values for 7 days (means±SD). FNESRW:
forced non-electric-shock running wheel; MCAo: middle cerebral artery
occlusion. Analysis of variance showed a significant difference (P<0.05),
with an F-value of 139.532 for 3 and 32 degrees of freedom.
Motor function
Figure 8 shows the results of the motor
performance of a lower limb grip that was measured using the inclined plane test for
7 days after surgery. Figure 8A shows the
average inclined plane angle of the lower limb grip on each day for the four groups
(sham, control, treadmill, and FNESRW), and Figure
8B shows the average angle that was obtained from the lower limb grip test
for each group over 7 days (means±SD). The inclined plane angle of the control group
was the lowest and significantly lower than that of the sham group on each of the 7
days (Figure 8A and B; P<0.05). Although no
significant difference between the inclined plane angles of the FNESRW and treadmill
groups was observed (Figure 8B), the FNESRW
group had significantly higher 7-day inclined plane angles than those of the control
group (Figure 8B; P<0.05). More
specifically, the increased trend of inclined angles on each day for the FNESRW group
was more obvious than that for the control group (Figure 8A), indicating that the recovery of motor function in the FNESRW
group was faster than that in the control group.
Figure 8
Average angle of the lower limb grip test over a period of 7 days.
A, Average daily inclined plane angle. B,
Average 7-day inclined plane angle. Data are reported as means±SD. FNESRW:
forced non-electric-shock running wheel; MCAo: middle cerebral artery
occlusion. Analysis of variance showed a significant difference (P<0.05),
with an F-value of 25.315 for 3 and 32 degrees of freedom.
Infarct volume (TTC)
The extent of the infarct lesions was examined using TTC staining (36). This method stains the normal parts of the
brain red. The cerebral infarct regions in the brains of the MCAo model rats remained
white after staining, and this reduced amount of staining clearly delineated the
areas of infarction (Figure 9A). The
experimental results show that the infarct size of the control group (291±20
mm3, P<0.05) was significantly higher than that of the sham group
after 7 days of reperfusion (Figure 9B).
Infarct sizes of the treadmill (42±88 mm3, P<0.05) and FNESRW (104±22
mm3, P<0.05) groups were significantly lower than that of the
control group (Figure 9B), indicating that
endurance exercise training (either on a treadmill or FNESRW) can effectively reduce
the infarct volume. There was no statistical difference between the treadmill and
FNESRW groups in infarct area, indicating the similar benefit of exercise
preconditioning in the animal ischemic stroke model.
Figure 9
Cerebral infarction volume 7 days after reperfusion. A,
Brain slices stained with TTC to visualize damaged lesions. B,
Average of the lesion volumes that were assessed using the reduction in TTC
staining (means±SD). FNESRW: forced non-electric-shock running wheel; MCAo:
middle cerebral artery occlusion. Analysis of variance showed a significant
difference (P<0.05), with an F-value of 107.872 for 3 and 32 degrees of
freedom.
Discussion
In this study, we developed an FNESRW platform with automatic exercise training patterns
to force rats to run in high-intensive training, and the ischemic stroke model for rats
was used to verify the benefit of exercise training on the proposed system. During
training, it was difficult for rats to exercise at 20 m/min, which is the required basic
speed for effective exercise intensity (30), on
the proposed platform without a rubber belt (the structure of the commercially available
running wheel). Rats were forced to run at 20 m/min or more on the structure of the MRW
runway in our experiments, and the rats would clutch a cross bar and fall down, which
induced injury, which is also a problem for commercially available MRWs (20). Two possible reasons exist for this occurrence.
First, compared with the flat plane trajectory of a treadmill, the curved trajectory of
a running wheel makes running more difficult and complex. Second, unlike the treadmill
track belt, which rats can step onto easily and smoothly, gaps are present between the
bars of the running wheel, which force the rats to run along the beams. To facilitate
steady running at higher wheel speeds, a layer of PVC runway was coated onto the outside
of the running wheel to prevent injury and improve running stability. This structure
allowed the rats to perform steady, high-intensity training at 30 m/min for 1 h.
Moreover, we automated the progressive exercise-training model by gradually accelerating
the training patterns to precisely and smoothly accelerate from 0 to 30 m/min, thus
preventing the rats from falling and becoming injured.The experimental results of the motor function (inclined plane test), mNSS values, and
infarct volume for the FNESRW group were significantly stronger (Figures 7-
9; P<0.05) compared with those of the control
group and were similar to the treadmill group, which indicated that the FNESRW provided
effective exercise training. Many animal neurophysiological studies have confirmed that
the benefit of a forced treadmill is significantly higher than that of a voluntary
running wheel, regardless of the intrinsic neuroprotection (16,17,37) or strengthening of the muscles (38). The experimental data obtained in the present study indicated that the
FNESRW platform could achieve benefits similar to those obtained with a treadmill, but
without using electric shock. Therefore, the proposed FNESRW platform can be used as an
alternative system in clinical animal studies. The overall effect of the proposed
platform was close to the treadmill group. Furthermore, recovery of hindlimbs after
training on the proposed FNESRW was more rapid than for the control group. Most of the
time, the running posture of the rats on the proposed platform involved the hindlimbs
being higher than the forelimbs. Therefore, we believe that this running posture causes
the hindlimbs of the rats to undergo heavier load training.The advantage of the proposed system is the lack of interference from electric shocks
and the stable training pace at high-intensity speeds. The protection against ischemic
stroke that is provided by a treadmill is partly from the use of electrical stimuli
(17). However, animals may exhibit a stress
response to such stimuli, and this should be acknowledged in forced treadmill studies.
Some studies have shown evidence of systemic stress, which may lead to adrenal
hypertrophy, splenic atrophy, and increased circulating corticosterone, especially in
male animals (18,39). Therefore, any results that are obtained in studies using treadmills may
not be completely caused by the exercise; instead, they may be partially caused by
psychological stress. To exclude the interference of the electrical stimulus, this study
proposed and implemented a wheel that does not use electric shock but provides the same
benefits as a traditional treadmill in clinical trials.The benefit of the variable speed movement pattern-triggered neuroprotective factor
against stroke is another relevant topic. Most animal experiments in the literature
maintained 20 m/min to 30 m/min on a treadmill for 30-60 min. The results showed that
achieving 75% of maximum oxygen uptake (VO2max) enhanced neuroprotective
factors, but it was unclear whether less than 60% of VO2max exercise also
increased neuroprotective factors (40). Another
advantage of the proposed system is that the number of revolutions and the revolution
time of the wheel can be programmed. Therefore, the FNESRW exercise platform can be used
to evaluate the neuroprotective benefit of running at various intensities and
durations.This study implemented an FNESRW system, which effectively trains rats in an automated
mode for exercise preconditioning, thereby significantly reducing infarct volume after
ischemic stroke. Unlike a traditional treadmill, the proposed platform forces a rat to
continue high-intensity running without using electric shock, resulting in experiments
with less interference. Automated progressive training patterns were constructed to
facilitate smooth running at high intensity. Moreover, in cooperation with automatic
acceleration training patterns, the PVC runway wheel allows rats to run more steadily
during high-intensity training. The experimental data showed that the proposed FNESRW
system for exercise preconditioning successfully provided a neuroprotective benefit of
exercise for rats.