Biocompatibility of Ricinus communis polymer with addition of calcium carbonate compared to titanium. Experimental study in guinea pigs.

Yorgos Luiz Santos De Salles Graça1, Ana Cristina Opolski, Barbara Evelin Gonçalves Barboza1, Bruna Olandoski Erbano1, Caroline Cantalejo Mazzaro1, Flávia Caroline Klostermann1, Enéas Eduardo Sucharski1, Luiz Fernando Kubrusly2.   

Abstract

OBJECTIVE: Tn class="Chemical">he aim of the present investigation was to determine whether the difference in inflammatory tissue reaction between the Riccinus communis (castor) polymer with calcium carbonate and the titanium implant is statistically significant.
METHODS: Thirty-two Cavia porcellus were allocated into four groups of eight animals each. We implanted the two types of materials in the retroperitoneal space of all the animals. They were euthanized at 7, 20, 30 and 40 days after surgery, and an histological study of the samples was conducted.
RESULTS: All implants showed characteristics of chronic inflammation regardless of the material and timepoint of evaluation. There was no statistically significant difference between Pm+CaCO3 and Ti with regard to the presence of granulation tissue, tissue congestion, histiocytes, lymphocytes, neutrophils, giant cells, and fibrosis (P> 0.05).
CONCLUSION: The castor oil polymer plus calcium carbonate implant was not statistically different from the titanium implant regarding inflammatory tissue reaction.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25140479      PMCID: PMC4389457          DOI: 10.5935/1678-9741.20140030

Source DB:  PubMed          Journal:  Rev Bras Cir Cardiovasc


INTRODUCTION

Cardiovascular diseases remain as tn class="Chemical">he leading cause of morbidity and mortality worldwide[. As life expectancy increases, the prevalence of these comorbidities is expected to become even greater. Congestive heart failure (CHF) is one of these diseases and accounts for an average of 400,000 new cases per year in the United States[. End-stage CHF is a clinical condin class="Chemical">tion for which few therapeutic options exist. Heart transplant is still an option in advanced CHF; however, it is a limited course of action due to the small number of donors and the high surgical risk involved[. In view of this, developing new support measures for these patients is a necessity. This prompted the concepn class="Chemical">tion of a Circulatory Assist Device (CAD). These devices, which are analogous to a human heart, are today a key component of the therapeutic support for patients in cardiogenic shock or end-stage heart failure[. In 1997, we began to develop an affordable CAD for the Brazilian public n class="Chemical">health system. We conducted tests in vitro[ and designed a device made of titanium, as is the great majority of such devices available worldwide. Experimental studies in vivo with sheep were performed and proved the efficacy of the device. In 2011, Kubrusly et al.[ initiated studies with a biocompatible material of national origin for the prospective production of a lower-cost device-this marked the beginning of the studies on the use of castor oil polymer (Pm) in the production of CADs. This polymer is formed by the reaction, in equal amounts by weight, between a polyol (OH) and a castor oil prepolymer[. In keeping with our primary objective, which is to develop a Brazilian-made device suited to tn class="Chemical">he resources of our country, we are at the stage of replacing costly mechanical parts for national-hence, less expensive-materials. Castor oil is a plant product extracted from tn class="Chemical">he beans of Ricinus communis, which is found in tropical and subtropical areas. The oil is a viscous liquid obtained by hot or cold pressing of the seeds or by solvent extraction[. The studies on the use of castor oil and its by-products for polyurethane synthesis started in the late 1940's with the preparation of polyurethane films for surface coating[. The first reports of the use of polyurethanes in medical applications date back to 1959, when Mandarino and Salvatore implanted a rigid polyetherurethane foam for bone fixation in situ. Castor oil polyurethanes can be produced with a range of different characteristics, from the most flexible (e.g., elastomers) to the most rigid ones (e.g., bone cements). The n class="Chemical">Pm polymer can be prepared pure or with added calcium carbonate (CaCO3) at a range of ratios by weight between the polyol, prepolymer, and CaCO3. Adding CaCO3 to the implant increases its mechanical strength and further reduces the production costs of the material[. In the present study, the ratio of 1/3 polyol, 1/3 prepolymer and 1/3 CaCO3 was used according to the mechanical tests performed by the manufacturer, Poliquil (Araraquara, SP), which point to that ratio as the optimal for medical use. In biocalcification studies, both in vivo and in vitro, Pm was regarded as a useful material not only for manufacturing implants, but also for the construction of accessories and devices such as pumps and valves for extracorporeal circulation[. The objecn class="Chemical">tive of the present study was to evaluate Pm with the addition of 33% CaCO3 (Pm+CaCO3) in order to gather sufficient histological data to ascertain low inflammatory reaction in the retroperitoneal space of guinea pigs compared with the reaction produced by titanium, thereby enabling the production of an even less expensive biomaterial, which would be affordable to the Brazilian population.

METHODS

This experimental, randomized interventional study was developed by tn class="Chemical">he Denton Cooley Institute at the Histology and Cell Biology Laboratories, the Animal Colony, and the Clinical and Surgical Experimentation Laboratory of the Faculdade Evangélica do Paraná.

Ethical issues

The present study was submitted to tn class="Chemical">he Research Ethics Committee of the Sociedade Evangélica Beneficente de Curitiba and approved under Technical Opinion 4277/11. This study was conducted in conformity with Law 6638 of May 8th, 1979-Regulations for the Didactic and Scientific Practice of Animal Vivisection. The standards established in the "Guide for the Care and Use of Laboratory Animals" (Institute of Laboratory Animal Resources, National Academy of Sciences, Washington, D.C., 1996) and the guidelines of the Brazilian College of Animal Experimentation (COBEA) were also met.

Sample

Thirty-two male guinea pigs (n class="Species">Cavia porcellus), Rodentia, Mammalia were used, with weights between 250-300 g (mean, 289.15±17.47 g), aged between 4-6 months, and previously healthy. The animals were obtained from the Instituto de Tecnologia do Paraná, and were raised and maintained under similar environmental and dietary conditions. The animals were randomized into four groups (A, B, C and D), with eight guinea pigs in each group. They were euthanized in a CO2 gas chamber, four animals at a time, at 7 (group A), 20 (group B), 30 (group C), and 40 (group D) days after the implant surgery[.

Experimental setting

The n class="Species">guinea pigs were housed in the animal colony of the Faculdade Evangélica do Paraná in compliance with the "Manual of Technical Guidelines for Animal Experimentation Colonies" of the Department of Microbiology, Biomedical Sciences Institute, Universidade de São Paulo[. The animals were acclimatized for seven days prior to the experiments, and were given filtered water and standard commercial chow ad libitum up to four hours before euthanasia. The operative procedures were conducted using sterile material and technique in a cooled environment at the Clinical and Surgical Experimentation Laboratory, Faculdade Evangélica do Paraná. Tramadol was administered intramuscularly at the dose of 1 mg/kg according to the analgesia protocol, with duration of 12-24 hours[.

Anesthesia

The animals were anesthetized as recommended by Radde et al.[, using ketamine and xylazine (87 and 13 mg/kg, respectively), both administered intraperitoneally.

Operative technique

Following anesthesia, each animal was placed in the prone position and its hair was removed with scissors, bilaterally, along the dorsum. Subsequently, surgical field antisepsis was performed using a polyvinylpirrolidone-iodine solution (PVP-I) (Figure 1A).
Fig. 1

A) Operative procedure surgical field antisepsis with polyvinylpirrolidone-iodine solution (PVP-I) and marking of the site of surgical incision; B) Implantation of the Pm+CaCO3 disc on the right-side hemibody; 1C) Implantation of the Ti disc on the left-side hemibody; 1D) Suture of the superficial plane with nylon 30

A) Operative procedure surgical field ann class="Chemical">tisepsis with polyvinylpirrolidone-iodine solution (PVP-I) and marking of the site of surgical incision; B) Implantation of the Pm+CaCO3 disc on the right-side hemibody; 1C) Implantation of the Ti disc on the left-side hemibody; 1D) Suture of the superficial plane with nylon 30 Local anesthesia was administered with 2% n class="Chemical">lidocaine diluted in normal saline. A 2-cm incision was subsequently made at 2 cm from the vertebral axis, to the right, in the region between the iliac crest and the last rib. The epithelium, the subcutaneous tissue and the fascia were penetrated, and the muscle layer was reached. This layer was carefully opened and the virtual retroperitoneal space was accessed, where the Pm+CaCO3 disc was implanted (Figure 1B). The procedure was repeated on the left side; however, the Ti disc was implanted this time (Figure 1C). The deep and superficial incision planes were sutured with nylon 30[ in a running fashion (Figure 1D).

Collection of the material for histopathological study

The surgical specimen was removed en bloc and immediately immersed in 10% neutral bufn class="Chemical">fered formalin, where it remained for 72 hours at room temperature. After fixation, the Ti and Pm+CaCO3 discs were removed through a lateral incision and the specimens were then rinsed in water for 24 hours, routinely processed and embedded in paraffin. The material was sectioned at 6 µm and stained by the hematoxylin-eosin (HE) technique for the cellular and capillary elements, and the technique of Masson's trichrome with Nile blue for the collagen fibers from fibrosis. The analysis was conducted using an Olympus® light microscope model DX 50. The aim of microscopy was to evaluate the inflammatory process elicited by each material, i.e., congestion, formation of granulation tissue, and peri-implant fibrosis. The n class="Disease">inflammation characteristics were qualitatively assessed for every slide of each group, and graded as absent, mild, moderate, or marked. The analyzed cells were histiocytes, neutrophils, lymphocytes, and giant cells. Histiocytes were defined in the present histopathological study as a type of normally stationary and inactive macrophage originated in the reticuloendothelial system that can be activated on stimulation; neutrophils, polynuclear white blood cells with neutrophilic granules; lymphocytes, a type of white blood cells between 10-12 µm in diameter, having a round nucleus with condensed chromatin and scarce, faintly basophilic cytoplasm; giant cells were defined as those formed by the fusion of several distinct cells. A x10 focusing eyepiece and x40 objective were used for tn class="Chemical">he microscopy study. The cell types were counted in 10 fields under the microscope in the areas involved in the inflammatory process induced by the foreign body.

Preparation and source of implants

The control material was n class="Chemical">Ti and Pm+CaCO3, the test material. The Ti alloy, characterized as grade 2, was obtained from a business company in the form of cylindrical bars 5 mm in diameter. The bars were composed of 99.7% Ti; 0.009% C; 0.095 Fe; 0.0003% H; 0.0038% N, and 0.152% O2. The mechanical properties of the bar were the following: % elongation (IN) L=32; % reduction in area L= 52; ultimate tensile strength (UTS) Ksi L= 78.8, and yield tensile strength (YS) Ksi (0.2%) L= 57. The n class="Chemical">Pm and the CaCO3 were obtained from a laboratory specialized in medical grade polymers (Poliquil, Araraquara, SP, Brazil). The preparation of the castor polymer implants began with equal amounts from one vial of polyol, one vial of vegetable polyurethane resin hardener, and an equal proportion by weight of CaCO3. These components were mixed at equal ratios by weight in a beaker using a glass stirring rod for 3 min until full homogenization was achieved. The homogenate thus obtained was placed in two insulin syringes. Following full polymerization, the syringes were sectioned with a scalpel blade into 3-mm-thick cross sections; subsequently, the plastic of the syringe barrel was removed[. Thus, discs with a thickness of 3 mm and a diameter of 5 mm were obtained to be implanted retroperitoneally in the guinea pigs. Disc antisepsis was performed by immersing the discs in 70% alcohol for 15 min. The Ti implants were produced by a specialized manufacturer (Neodent, Curitiba, PR, Brazil). The Ti bar was attached to the plate of an engine lathe (Tormax 20A -ROMI) and cut with the aid of a cutting fluid (Quimatic oil). Subsequently, the discs were smoothed to be rid of rough spots or irregularities resulting from the first process. The Ti implants had the same dimensions as the Pm implants and were also sterilized in 70% alcohol.

Statistical analysis

Regarding the dichotomous qualitan class="Chemical">tive variables, the test binomial was used in the analysis of the difference between the Pm+CaCO3 and Ti implants at each timepoint. When considering the materials separately, the four groups were compared using Fisher's exact test. Values of P<0.05 indicated statistical significance. The data were analyzed using the SPSS software version 20.0.

RESULTS

Regarding peri-implant tissue n class="Disease">inflammation, 100% of the implants showed histological characteristics of chronic inflammation; therefore, no statistically significant difference was found between the Pm+CaCO3 and the Ti group regardless of the evaluation timepoint (P=1 across comparisons). The presence of lymphocytes, neutrophils, giant cells, and peri-implant tissue congestion was consistently not marked over time for either implant material (P=1 across comparisons). For some variables, the time effect was significant. The analysis of both Pm+CaCO3 and Ti implants showed a progressive and linear decrease in the granulation process and in the presence of histiocytes. For both materials, these factors appeared markedly in the group evaluated in the first 7 days of the study (group A) whereas they were predominantly graded as not marked in the last two groups (C and D) (P<0.05). However, there was no statistically significant difference in the behavior of these variables between the two types of material (P=1 across comparisons). Albeit also without statistical differences between the materials, peri-implant fibrosis was found to be marked in groups A and B, and not marked in groups C and D. A slight tendency was noted for the polymer implant to exhibit less fibrosis than the Ti in groups C and D, although this was not statistically significant (Figures 2 and 3).
Fig. 2A

Light microscopy – Titanium-associated fibrosis. Staining by Masson’s Trichrome with Nile Blue

Fig. 3

Analysis of the difference in marked fibrosis between groups Pm+CaCO3 and Ti according to the evaluation timepoints

Light microscopy – Titanium-associated fibrosis. Staining by Masson’s Trichrome with Nile Blue Light microscopy – Pm+CaCO3 -associated fibrosis. Staining by Masson’s Trichrome with Nile Blue Analysis of the difference in marked fibrosis between groups Pm+CaCO3 and Ti according to the evaluation timepoints

DISCUSSION

As established in tn class="Chemical">he previous study in the same line of research, we maintained the methodology[ in order to obtain materials that are low-cost, abundant in nature, and with an acceptable biocompatibility profile that would ideally replace the time-honored materials in medical practice, as these are expensive and difficult to be obtained. The favorable characterisn class="Chemical">tics of Pm were first reported by such authors as Ohara et al.[, Carvalho et al.[, Ignácio et al.[, Silva[, and Kubrusly[, thereby opening the way to the use of this polymer in orthopedics, orthodontics, bucomaxilar surgery, neurosurgery, and cardiovascular surgery. Furthermore, the production process of Pm is very attractive, as it needs no catalysts and shows simple processability and flexibility in formulation, thereby enabling the addition of other components- in the present case, CaCO3- without interfering with the chemical reaction. The n class="Chemical">Pm material shows versatility in terms of curing temperature, with a maximum exothermic peak at 45ºC and no production of post-reaction free residual monomers-an undesirable occurrence for assisted circulation devices, common among polymers, which prompted researchers to use titanium for this purpose. Dias et al.[ conducted a study with four capuchin monkeys (Cebus apella), wherein the investigators placed a Pm implant in a bone defect previously created in the nasal dorsum of the animals; later, the histological analysis revealed no foreign body granulomas or phagocytic cells. Although no bone tissue analysis was performed in the present study, no foreign body granulomas were found on histological analysis. A study by Mastrantonio and Ramalho[ evaluated the response of the connective tissue of mice to Pm over a period of 60 days and, again, biocompatibility results were favorable. Titanium is considered to be an inert material; authors such as Van Noort et al.[ have extensively demonstn class="Species">rated its applicability in medical grade alloys since mid-20th century. Alloys of Ti have been widely used as bone substitutes, in implantable materials in the human body such as screws and plates, and are present today in reconstructive surgery as well. Likewise, Pm has been expanding its range of applications. In the present study, it was noted that tn class="Chemical">he predominant type of inflammation in both study materials (Pm+CaCO3 and Ti) was chronic inflammation, i.e., predominance of monomorphonuclear cells regardless of the assessment timepoint. The initial seven-day period is directly related to the type of suture used in the surgery. Siqueira and Dantas[ have defined this length of time as the period of deposition of hyaluronic acid and collagen, both of which are produced in an attempt to reconstitute the injured tissues. In the current study, the presence of granulation tissue and histiocytes was marked in the first seven days, albeit without statistical significance when the two types of material were compared. The lower amount of n class="Disease">fibrosis found in groups C and D, i.e., at 30 and 40 postoperative days, diverged from the results of Costa et al.[, who noted the formation of dense fibrous tissue surrounding the Pm implant. In the present study, as in the previous study by Kubrusly and co-workers[, for both materials, the adjacent connective tissue showed normal histological characteristics and a tendency toward decreasing tissue reaction with increasing post-implantation timepoints. Furthermore, macro- and microscopically, no n class="Chemical">polymer structure degradation occurred when it was subjected to the body temperature ranges of the guinea pigs. This can be reinforced by the fact that the polyurethanes exhibited thermal stability up to 210ºC, which demonstrates that these polymers will not undergo thermal decomposition at ambient temperature[. In addition to showing stability at high tempen class="Species">ratures, Pm+CaCO3 is a Brazilian technology and represents the possibility of providing a lighter implantable device for the patient. Our CAD in study, the K-pump, made of steel, weighs 194 g. A titanium-made device with the same dimensions is estimated to weigh between 85-95 g. The weight of the Pm+CaCO3 implant will be approximately 45-55 g, which is below the average of most currently available fully implantable CADs and suitable for pediatric patients and small-built adults. In line with the data from tn class="Chemical">he study with pure Pm[, Pm+CaCO3 also has identical biocompatibility properties to those of the Ti implant. In addition to the preserved biocompatibility, the new combination confers greater mechanical strength and a smaller proportion of polymer raw material is used in its preparation. Therefore, production costs are further reduced, since smaller amounts of polyol and prepolymer are needed to produce our CAD. This economy of 33 % in raw material affords a 10-20% reduction in the production costs of the core structure of our CAD; this represents a further step toward our goal.

CONCLUSION

No statisn class="Chemical">tically significant difference was found between the Pm+CaCO3 and the Ti implants with respect to the induced tissue reaction in guinea pigs.
Abbreviations, acronyms & symbols
CaCO3Calcium carbonate
CADCirculatory assist device
CO2Carbon dioxide
COBEABrazilian College of Animal Experimentation
CHFCongestive heart failure
HEHematoxilin-eosin
PmCastor oil polymer
Pm+CaCO3Castor oil polymer with added calcium carbonate
PVP-IPolyvinylpirrolidone-iodine solution
TiTitanium
Authors’ roles & responsibilities
YLSGReview of the literature; participation in the experimental surgeries; drafting of the manuscript
ACOReview of the literature; participation in the experimental surgeries; drafting of the manuscript
BEGBReview of the literature; participation in the experimental surgeries; drafting of the manuscript
BOEReview of the literature; participation in the experimental surgeries; drafting of the manuscript
CCMReview of the literature; participation in the experimental surgeries; drafting of the manuscript
FCKReview of the literature; participation in the experimental surgeries; drafting of the manuscript
EESReview of the literature; participation in the experimental surgeries; drafting of the manuscript
LFKReview of the literature; participation in the experimental surgeries; drafting of the manuscript
  9 in total

Review 1.  Heart failure with normal ejection fraction.

Authors:  Meliza Goi Roscani; Luiz Shiguero Matsubara; Beatriz Bojikian Matsubara
Journal:  Arq Bras Cardiol       Date:  2010-05       Impact factor: 2.000

2.  Mechanical circulatory support: a great gap in Brazilian cardiac surgery.

Authors:  Luiz Felipe Pinho Moreira; Anderson Benício
Journal:  Rev Bras Cir Cardiovasc       Date:  2010 Oct-Dec

3.  Experimental study of pulsatile implantable electromechanical artificial ventricle.

Authors:  Jarbas Jakson Dinkhuysen; Aron Andrade; Carlos Conteras; Paulo Paredes Paulista; Juliana Leme; Ricardo Manrique
Journal:  Rev Bras Cir Cardiovasc       Date:  2011 Jan-Mar

4.  [Clinical and histopathological study of tissue reactivity to monofilament suture materials: nylon and poliglecaprone 25 in rats].

Authors:  Camila Maria Beder Ribeiro; Valdemiro Amaro da Silva Júnior; Joaquim Celestino da Silva Neto; Belmiro Cavalcanti do Egito Vasconcelos
Journal:  Acta Cir Bras       Date:  2005-07-18       Impact factor: 1.388

5.  Histologic and histometric evaluation of rat alveolar wound healing around polyurethane resin implants.

Authors:  T L Carvalho; C A Araújo; J M Teófilo; L G Brentegani
Journal:  Int J Oral Maxillofac Surg       Date:  1997-04       Impact factor: 2.789

6.  Evaluation of anaesthetic regimens in guineapigs.

Authors:  G R Radde; A Hinson; D Crenshaw; L A Toth
Journal:  Lab Anim       Date:  1996-07       Impact factor: 2.471

7.  Biocompatibility of Ricinus comunnis polymer compared to titanium implant used in artificial hearts. Experimental study in guinea pigs.

Authors:  Luiz Fernando Kubrusly; Yorgos Luiz Santos de Salles Graça; Enéas Eduardo Sucharski; Ana Cristina Lira Sobral; Marcia Olandoski; Fernando Bermudez Kubrusly
Journal:  Rev Bras Cir Cardiovasc       Date:  2012 Jul-Sep

8.  Implantable electrical left ventricular assist system: bridge to transplantation and the future.

Authors:  P M Portner; P E Oyer; D G Pennington; W A Baumgartner; B P Griffith; W R Frist; D J Magilligan; G P Noon; N Ramasamy; P J Miller
Journal:  Ann Thorac Surg       Date:  1989-01       Impact factor: 4.330

9.  Ricinus communis biocompatibility histological study in the nose of Cebus apella monkeys.

Authors:  Paulo Cesar de Jesus Dias; Lidio Granato; Lizeti de Toledo de Oliveira Ramalho; José Américo de Oliveira; Hermes Pretel
Journal:  Braz J Otorhinolaryngol       Date:  2009 May-Jun
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.