Literature DB >> 25138611

Comparison of the long-term skeletal stability between a biodegradable and a titanium fixation system following BSSO advancement - a cohort study based on a multicenter randomised controlled trial.

N B van Bakelen1, B D A Boermans2, G J Buijs2, J Jansma2, G J Pruim3, Th J M Hoppenreijs4, J E Bergsma5, B Stegenga6, R R M Bos2.   

Abstract

Biodegradable fixation systems could reduce or eliminate the problems associated with removal of titanium plates. A multicenter randomised controlled trial (RCT) was performed in the Netherlands from December 2006-July 2009, and originally 230 injured and orthognathic patients were included. The patients were randomly assigned to either a titanium control group (KLS Martin) or to a biodegradable test group (Inion CPS). The aim of the present study was to compare the long-term skeletal stability of advancement bilateral sagittal split osteotomies (BSSO) of a biodegradable system and a titanium system. Only patients from the original RCT who were at least 18 years old and who had a BSSO advancement osteotomy were included. Those who had simultaneous Le Fort I osteotomy or genioplasty were excluded. Analysis of skeletal stability was made by digital tracing of lateral cephalograms. Long-term skeletal stability in BSSO advancement did not differ significantly between patients treated with biodegradable plates and screws and those treated with titanium plates and screws. Given the comparable amount of relapse, the general use of Inion CPS in the treatment of BSSO advancement should not be discouraged. On the basis of other properties a total picture of the clinical use can be obtained; the short-term stability, the intraoperative switches, the number of plates removed and cost-effectiveness. Trial registration of original RCT: http://www.controlled-trials.com; ISRCTN 44212338.
Copyright © 2014. Published by Elsevier Ltd.

Entities:  

Keywords:  Inion; KLS Martin; oral surgery.; relapse; surgical fixation devices; treatment outcome

Mesh:

Substances:

Year:  2014        PMID: 25138611     DOI: 10.1016/j.bjoms.2014.06.014

Source DB:  PubMed          Journal:  Br J Oral Maxillofac Surg        ISSN: 0266-4356            Impact factor:   1.651


  5 in total

Review 1.  Orthognathic Surgery: A Review of Articles Published in 2014-2015.

Authors:  Vaibhav Singh; K N V Sudhakar; Rajat Mohanty; Suravi Chatterjee
Journal:  J Maxillofac Oral Surg       Date:  2016-12-17

2.  Evaluation of the rigidity of sagittal split ramus osteotomy fixation using four designs of biodegradable and titanium plates--a numerical study.

Authors:  Safieh Albougha; Mhd Hassan Albogha; Mhd Ayham Darwich; Khaldoun Darwich
Journal:  Oral Maxillofac Surg       Date:  2015-03-19

Review 3.  Overview of innovative advances in bioresorbable plate systems for oral and maxillofacial surgery.

Authors:  Takahiro Kanno; Shintaro Sukegawa; Yoshihiko Furuki; Yoshiki Nariai; Joji Sekine
Journal:  Jpn Dent Sci Rev       Date:  2018-04-05

4.  Is There Any Differences in Dento-Skeletal Stability between One Vs. Three-Screw Fixation of Mandible Following Bilateral Sagittal Split Osteotomy (BSSO)?

Authors:  Majid Eshghpour; Sahand Samieirad; Farzaneh MohammadZadeh Mahrokh; Niloofar EbrahimZadeh; Samine Mozaffar; Haleh Hashemzadeh
Journal:  World J Plast Surg       Date:  2022-07

Review 5.  Efficacy and morbidity of biodegradable versus titanium osteosyntheses in orthognathic surgery: A systematic review with meta-analysis and trial sequential analysis.

Authors:  Barzi Gareb; Nico B van Bakelen; Pieter U Dijkstra; Arjan Vissink; Ruud R M Bos; Baucke van Minnen
Journal:  Eur J Oral Sci       Date:  2021-06-15       Impact factor: 2.612

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.