Literature DB >> 25136982

Registration of 2D histological sections with 3D micro-CT datasets from small animal vertebrae and tibiae.

Oleg Museyko1, Robert Percy Marshall, Jing Lu, Andreas Hess, Georg Schett, Michael Amling, Willi A Kalender, Klaus Engelke.   

Abstract

The aim of this study was the registration of digitized thin 2D sections of mouse vertebrae and tibiae used for histomorphometry of trabecular bone structure into 3D micro computed tomography (μCT) datasets of the samples from which the sections were prepared. Intensity-based and segmentation-based registrations (SegRegs) of 2D sections and 3D μCT datasets were applied. As the 2D sections were deformed during their preparation, affine registration for the vertebrae was used instead of rigid registration. Tibiae sections were additionally cut on the distal end, which subsequently undergone more deformation so that elastic registration was necessary. The Jaccard distance was used as registration quality measure. The quality of intensity-based registrations and SegRegs was practically equal, although precision errors of the elastic registration of segmentation masks in tibiae were lower, while those in vertebrae were lower for the intensity-based registration. Results of SegReg significantly depended on the segmentation of the μCT datasets. Accuracy errors were reduced from approximately 64% to 42% when applying affine instead of rigid transformations for the vertebrae and from about 43% to 24% when using B-spline instead of rigid transformations for the tibiae. Accuracy errors can also be caused by the difference in spatial resolution between the thin sections (pixel size: 7.25 μm) and the μCT data (voxel size: 15 μm). In the vertebrae, average deformations amounted to a 6.7% shortening along the direction of sectioning and a 4% extension along the perpendicular direction corresponding to 0.13-0.17 mm. Maximum offsets in the mouse tibiae were 0.16 mm on average.

Entities:  

Keywords:  2D–3D image registration; deformation quantification; histological sections; trabecular structure; μCT

Mesh:

Year:  2014        PMID: 25136982     DOI: 10.1080/10255842.2014.941824

Source DB:  PubMed          Journal:  Comput Methods Biomech Biomed Engin        ISSN: 1025-5842            Impact factor:   1.763


  4 in total

1.  A correlative imaging based methodology for accurate quantitative assessment of bone formation in additive manufactured implants.

Authors:  Hua Geng; Naomi M Todd; Aine Devlin-Mullin; Gowsihan Poologasundarampillai; Taek Bo Kim; Kamel Madi; Sarah Cartmell; Christopher A Mitchell; Julian R Jones; Peter D Lee
Journal:  J Mater Sci Mater Med       Date:  2016-05-06       Impact factor: 3.896

2.  Reliable landmarks for precise topographical analyses of pathological structural changes of the ovine tibial plateau in 2-D and 3-D subspaces.

Authors:  Tamás Oláh; Jan Reinhard; Liang Gao; Lars K H Goebel; Henning Madry
Journal:  Sci Rep       Date:  2018-01-08       Impact factor: 4.379

3.  A 3D journey on virtual surfaces and inner structure of ossa genitalia in Primates by means of a non-invasive imaging tool.

Authors:  Federica Spani; Maria Pia Morigi; Matteo Bettuzzi; Massimiliano Scalici; Monica Carosi
Journal:  PLoS One       Date:  2020-01-30       Impact factor: 3.240

4.  Nonlinear Image Registration and Pixel Classification Pipeline for the Study of Tumor Heterogeneity Maps.

Authors:  Laura Nicolás-Sáenz; Sara Guerrero-Aspizua; Javier Pascau; Arrate Muñoz-Barrutia
Journal:  Entropy (Basel)       Date:  2020-08-28       Impact factor: 2.524

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.