S Chopra1, A Patidar, T Dora, N Moirangthem, S N Paul, R Engineer, U Mahantshetty, S K Shrivastava.   

Abstract

OBJECTIVE: To compare internal target volume (ITV) generated using population-based displacements (ITV_study) with empty and full bladder scan fusion (ITV_EBFB) for organ-at-risk (OAR) doses during adjuvant intensity-modulated radiation therapy (IMRT) for cervical cancer.
METHODS: From January 2011 to October 2012, patients undergoing IMRT were included. CT simulation was carried out after inserting vault markers. Planning target volume (PTV)_EBFB received 50 Gy per 25 fractions. Pre-treatment megavoltage CT (MVCT) was performed. MVCTs were registered using bony landmarks with Day 1 MVCT. Displacement of the centre of mass of markers was measured along each axis. Directional ITV was calculated using mean ± 2 standard deviations (SDs) (ITV_study). Replanning was performed using PTV study, and OAR doses were compared with PTV_EBFB using Wilcoxon test.
RESULTS: A total of 348/386 data sets were evaluable for 16 patients. The median vaginal displacement was 1.2 mm (SD, 1.3 mm), 4.0 mm (SD, 3.5 mm) and 2.8 mm (SD, 3.3 mm) in the mediolateral, superoinferior and anteroposterior directions, respectively. The ITV margins were 4.1, 10.3 and 10.6 mm. ITV_study and ITV_EBFB were 115.2 cm(3) (87.7-152.2 cm(3)) and 151 cm(3) (95.7-277.1 cm(3)) (p < 0.0001), respectively. PTV_study and PTV_EBFB were 814 and 881 cm(3) (p < 0.0001), respectively. Median doses to the bladder were lower with the PTV_study (46.2 Gy vs 43.2 Gy; p = 0.0001), and a similar trend was observed in the volume of the small bowel receiving 40 Gy (68.2 vs 60.1 cm(3); p = 0.09).
CONCLUSION: Population-based PTV margins can lead to reduction in OAR doses. ADVANCES IN KNOWLEDGE: Population-based ITV may reduce OAR doses while executing adjuvant IMRT for cervical cancer.

Entities:  

Mesh:

Year:  2014        PMID: 25135439      PMCID: PMC4170874          DOI: 10.1259/bjr.20140428

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  20 in total

1.  Geometrical uncertainties, radiotherapy planning margins, and the ICRU-62 report.

Authors:  Joep C Stroom; Ben J M Heijmen
Journal:  Radiother Oncol       Date:  2002-07       Impact factor: 6.280

2.  Interfraction motion of the vaginal apex during postoperative intensity modulated radiation therapy: are we missing the target?

Authors:  Dominique Rash; Yolanda Hagar; Jing Cui; Jon-Paul Hunt; Richard Valicenti; Jyoti Mayadev
Journal:  Int J Gynecol Cancer       Date:  2013-02       Impact factor: 3.437

3.  Factors influencing bowel sparing in intensity modulated whole pelvic radiotherapy for gynaecological malignancies.

Authors:  Petra Georg; Dietmar Georg; Martin Hillbrand; Christian Kirisits; Richard Pötter
Journal:  Radiother Oncol       Date:  2006-06-12       Impact factor: 6.280

4.  A randomized trial of pelvic radiation therapy versus no further therapy in selected patients with stage IB carcinoma of the cervix after radical hysterectomy and pelvic lymphadenectomy: A Gynecologic Oncology Group Study.

Authors:  A Sedlis; B N Bundy; M Z Rotman; S S Lentz; L I Muderspach; R J Zaino
Journal:  Gynecol Oncol       Date:  1999-05       Impact factor: 5.482

5.  A phase II study of intensity modulated radiation therapy to the pelvis for postoperative patients with endometrial carcinoma: radiation therapy oncology group trial 0418.

Authors:  Anuja Jhingran; Kathryn Winter; Lorraine Portelance; Brigitte Miller; Mohammad Salehpour; Rakesh Gaur; Luis Souhami; William Small; Lawrence Berk; David Gaffney
Journal:  Int J Radiat Oncol Biol Phys       Date:  2012-04-28       Impact factor: 7.038

6.  Intensity-modulated whole pelvic radiation therapy in patients with gynecologic malignancies.

Authors:  J C Roeske; A Lujan; J Rotmensch; S E Waggoner; D Yamada; A J Mundt
Journal:  Int J Radiat Oncol Biol Phys       Date:  2000-12-01       Impact factor: 7.038

7.  Predictors of grade 3 or higher late bowel toxicity in patients undergoing pelvic radiation for cervical cancer: results from a prospective study.

Authors:  Supriya Chopra; Tapas Dora; Anand N Chinnachamy; Biji Thomas; Sadhna Kannan; Reena Engineer; Umesh Mahantshetty; Reena Phurailatpam; Siji N Paul; Shyam Kishore Shrivastava
Journal:  Int J Radiat Oncol Biol Phys       Date:  2014-03-01       Impact factor: 7.038

8.  Consensus guidelines for delineation of clinical target volume for intensity-modulated pelvic radiotherapy in postoperative treatment of endometrial and cervical cancer.

Authors:  William Small; Loren K Mell; Penny Anderson; Carien Creutzberg; Jennifer De Los Santos; David Gaffney; Anuja Jhingran; Lorraine Portelance; Tracey Schefter; Revathy Iyer; Mahesh Varia; Kathryn Winter; Arno J Mundt
Journal:  Int J Radiat Oncol Biol Phys       Date:  2007-11-26       Impact factor: 7.038

9.  Dosimetric comparison of bone marrow-sparing intensity-modulated radiotherapy versus conventional techniques for treatment of cervical cancer.

Authors:  Loren K Mell; Hanifi Tiryaki; Kang-Hyun Ahn; Arno J Mundt; John C Roeske; Bulent Aydogan
Journal:  Int J Radiat Oncol Biol Phys       Date:  2008-08-01       Impact factor: 7.038

10.  Protocol for a phase III randomised trial of image-guided intensity modulated radiotherapy (IG-IMRT) and conventional radiotherapy for late small bowel toxicity reduction after postoperative adjuvant radiation in Ca cervix.

Authors:  Supriya Chopra; Reena Engineer; Umesh Mahantshetty; Shagun Misra; Reena Phurailatpam; Siji N Paul; Sadhna Kannan; Rajendra Kerkar; Amita Maheshwari; Ts Shylasree; Jaya Ghosh; Sudeep Gupta; Biji Thomas; Shalini Singh; Sanjiv Sharma; Srinivas Chilikuri; Shyam Kishore Shrivastava
Journal:  BMJ Open       Date:  2012-12-12       Impact factor: 2.692

View more
  2 in total

1.  Internal target volume for post-hysterectomy vaginal recurrences of cervical cancers during image-guided radiotherapy.

Authors:  Maheshkumar N Upasani; Supriya Chopra; Reena Engineer; Umesh Mahantshetty; Seema Medhi; Zubin Mehta; Shyam K Shrivastava
Journal:  Br J Radiol       Date:  2015-08-07       Impact factor: 3.039

2.  Does ITV vaginal procedure ensure dosimetric coverage during IMRT of post-operative gynaecological tumours without instructions concerning rectal filling?

Authors:  Ramona Verges; Alexandra Giraldo; Alejandro Seoane; Elisabet Toral; M Carmen Ruiz; Ariadna Pons; Jordi Giralt
Journal:  Rep Pract Oncol Radiother       Date:  2018-03-02