Literature DB >> 25135250

Selection of tendon grafts for distal radioulnar ligament reconstruction and report of a modified technique.

Eugene Jang1, Christopher J Dy1, Scott W Wolfe2.   

Abstract

PURPOSE: To investigate the graft length necessary to complete a distal radioulnar ligament reconstruction and assess the suitability of several tendon graft sources.
METHODS: We measured the graft length needed to complete the distal radioulnar ligament reconstruction in 7 fresh-frozen cadaver specimens. The pure tendon lengths of 7 tendon graft sources were measured: palmaris longus, extensor indicis proprius, slips of extensor digiti minimi and abductor pollicis longus, and portions of flexor carpi ulnaris, flexor carpi radialis, and extensor carpi ulnaris. A modified technique that allows for a shorter length of graft is also described, and the suitability of each graft source for this technique was assessed.
RESULTS: The mean graft lengths needed to complete the original and modified reconstructions were 138 mm and 89 mm, respectively. The average length of the tendon graft when measured as pure tendon was: palmaris longus (127 mm), slip of extensor digiti minimi (112 mm), extensor indicis proprius (100 mm), partial flexor carpi radialis (87 mm), slip of abductor pollicis longus (69 mm), partial flexor carpi ulnaris (67 mm), and partial extensor carpi ulnaris (67 mm). The palmaris longus was too short for the original technique in the majority of specimens but was sufficient to complete the modified technique in every specimen that had a palmaris longus. Six specimens also had an extensor indicis proprius of suitable length for the modified technique.
CONCLUSIONS: The length of donor graft required for the modified reconstruction was significantly less than that needed for the original reconstruction. Three specimens had no donor tendons sufficiently long to complete the original technique if a pure tendon graft were used, whereas the modified technique could be completed in all specimens. CLINICAL RELEVANCE: Many tendon graft sources in the upper extremity are of insufficient length to complete the distal radioulnar ligament reconstruction as described. A modified technique using suture anchors may be a useful alternative in such cases.
Copyright © 2014 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Distal radioulnar ligament; cadaver; distal radioulnar joint; reconstruction; tendon graft

Mesh:

Year:  2014        PMID: 25135250      PMCID: PMC4177282          DOI: 10.1016/j.jhsa.2014.07.020

Source DB:  PubMed          Journal:  J Hand Surg Am        ISSN: 0363-5023            Impact factor:   2.230


  19 in total

1.  Repair of chronic ruptures of the distal biceps tendon using flexor carpi radialis tendon graft.

Authors:  H J Levy; A A Mashoof; D Morgan
Journal:  Am J Sports Med       Date:  2000 Jul-Aug       Impact factor: 6.202

2.  Tendon graft donor sites.

Authors:  M A Wehbé
Journal:  J Hand Surg Am       Date:  1992-11       Impact factor: 2.230

3.  The detailed anatomy of the palmar cutaneous nerves and its clinical implications.

Authors:  H S Matloub; J G Yan; A B Mink Van Der Molen; L L Zhang; J R Sanger
Journal:  J Hand Surg Br       Date:  1998-06

4.  An anatomic reconstruction of the distal radioulnar ligaments for posttraumatic distal radioulnar joint instability.

Authors:  Brian D Adams; Richard A Berger
Journal:  J Hand Surg Am       Date:  2002-03       Impact factor: 2.230

Review 5.  The prevalence of absence of the palmaris longus--a study in a Chinese population and a review of the literature.

Authors:  S J Sebastin; M E Puhaindran; A Y T Lim; I J Lim; W H Bee
Journal:  J Hand Surg Br       Date:  2005-10

6.  The palmar cutaneous branch of the median nerve and the palmaris longus tendon: a cadaveric study.

Authors:  P A Dowdy; R S Richards; R M McFarlane
Journal:  J Hand Surg Am       Date:  1994-03       Impact factor: 2.230

7.  Adequacy of palmaris longus and plantaris tendons for tendon grafting.

Authors:  Michael G Jakubietz; Danni F Jakubietz; Joerg G Gruenert; Robert Zahn; Rainer H Meffert; Rafael G Jakubietz
Journal:  J Hand Surg Am       Date:  2011-04       Impact factor: 2.230

8.  Thumb basal joint arthroplasty using abductor pollicis longus tendon: an average 5.5-year follow-up.

Authors:  Andrew J Kochevar; Christine N Adham; Mehdi N Adham; Michael F Angel; Marcus D Walkinshaw
Journal:  J Hand Surg Am       Date:  2011-07-01       Impact factor: 2.230

9.  Chronic instability of the distal radioulnar joint.

Authors:  Brian D Adams; Ericka Lawler
Journal:  J Am Acad Orthop Surg       Date:  2007-09       Impact factor: 3.020

10.  Flexor carpi ulnaris transfer for radial nerve palsy: functional testing of long-term results.

Authors:  K B Raskin; E F Wilgis
Journal:  J Hand Surg Am       Date:  1995-09       Impact factor: 2.230

View more
  3 in total

Review 1.  Morphometric analysis and surgical adequacy of palmaris longus as a tendon graft. A systematic review of cadaveric studies.

Authors:  Kaissar Yammine; Mirela Erić
Journal:  Surg Radiol Anat       Date:  2019-11-18       Impact factor: 1.246

2.  Biomechanical evaluation of interference screw fixation techniques for distal radioulnar ligament reconstruction: a cadaveric experimental study.

Authors:  Fengming Gu; Xiaodong Fang; Gang Zhao; Xiaoyun Pan; Fei Xiong; Qiuwen Ying; Jingyi Mi
Journal:  Arch Orthop Trauma Surg       Date:  2022-04-10       Impact factor: 2.928

3.  Predicting Tendon Tissue Grafting Source From the Extensors of Long Fingers: A Systematic Review of Cadaveric Studies.

Authors:  Kaissar Yammine
Journal:  Hand (N Y)       Date:  2018-05-04
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.