Literature DB >> 25132194

Twenty-four-hour intraocular pressure patterns in patients with thyroid eye disease.

Anjali S Parekh1, Kaweh Mansouri, Robert N Weinreb, Ali Tafreshi, Bobby S Korn, Don O Kikkawa.   

Abstract

BACKGROUND: To prospectively investigate the safety, tolerability and 24-h intraocular pressure (IOP) patterns in patients with thyroid eye disease (TED) using a contact lens sensor (CLS).
DESIGN: Prospective study. PARTICIPANTS: Ten patients with established TED.
METHODS: Ten eyes of 10 patients were prospectively evaluated in an ambulatory 24-h IOP monitoring session using the CLS (Sensimed AG, Lausanne, Switzerland). Patients pursued daily activities, and sleep behaviour was uncontrolled. MAIN OUTCOME MEASURES: Incidence of adverse events (AEs) and tolerability (scale of 0-10, increasing intolerance) were assessed. IOP patterns were evaluated using a cosinor rhythmometry model, and linear regression slopes were constructed for the transition from wake/sitting (W/S) to sleep/supine (S/S) and vice versa.
RESULTS: Mean age was 61.8 ± 21.6 years, and 90% of patients were female. Main AEs were blurred vision (50%), conjunctival hyperaemia (100%) and superficial punctate keratitis (20%). Tolerability of the lens was found to be 1.5 ± 0.7. Positive linear slopes of the CLS signal from wake to sleep were detected (18.0 ± 43.8 arbitrary units [a.u.]; P = 0.254), whereas at the transition from S/S to W/S a significant decrease (-62.9 ± 56.8 a.u.; P = 0.010) was found. Five patients (50%) had a significant nocturnal/sleep acrophase with the peak occurring at 6:30 a.m. The mean amplitude of the 24-h curves was 102.2 ± 52.6 a.u.
CONCLUSIONS: In patients with TED, the CLS provides a safe and well-tolerated approach to 24-h IOP monitoring. After modelling the 24-h IOP curves, TED patients were found to have a morning acrophase.
© 2014 Royal Australian and New Zealand College of Ophthalmologists.

Entities:  

Keywords:  contact lens sensor; glaucoma; intraocular pressure; thyroid eye disease

Mesh:

Year:  2014        PMID: 25132194     DOI: 10.1111/ceo.12400

Source DB:  PubMed          Journal:  Clin Exp Ophthalmol        ISSN: 1442-6404            Impact factor:   4.207


  10 in total

1.  Relationship between the 24-h variability of blood pressure, ocular perfusion pressure, intraocular pressure, and visual field defect in thyroid associated orbitopathy.

Authors:  Yunhai Tu; Bangxun Mao; Jiagen Li; Weijie Liu; Mingna Xu; Qi Chen; Wencan Wu
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2020-06-12       Impact factor: 3.117

2.  Effect of glaucoma medications on 24-hour intraocular pressure-related patterns using a contact lens sensor.

Authors:  Kaweh Mansouri; Felipe A Medeiros; Robert N Weinreb
Journal:  Clin Exp Ophthalmol       Date:  2015-08-16       Impact factor: 4.207

Review 3.  Systematic Review of Current Devices for 24-h Intraocular Pressure Monitoring.

Authors:  Sabita M Ittoop; Jeffrey R SooHoo; Leonard K Seibold; Kaweh Mansouri; Malik Y Kahook
Journal:  Adv Ther       Date:  2016-08-16       Impact factor: 3.845

Review 4.  The Sensimed Triggerfish contact lens sensor: efficacy, safety, and patient perspectives.

Authors:  Grace E Dunbar; Bailey Yuguan Shen; Ahmad A Aref
Journal:  Clin Ophthalmol       Date:  2017-05-08

5.  Intraocular Pressure-Lowering Effect of Latanoprost Is Hampered by Defective Cervical Lymphatic Drainage.

Authors:  Young Kook Kim; Kyeong Ik Na; Jin Wook Jeoung; Ki Ho Park
Journal:  PLoS One       Date:  2017-01-12       Impact factor: 3.240

Review 6.  24-hour Intraocular pressure monitoring: the way ahead.

Authors:  Shibal Bhartiya; Meenakshi Gangwani; R Balwant Kalra; Anand Aggarwal; Meghal Gagrani; Kumar Namagiri Sirish
Journal:  Rom J Ophthalmol       Date:  2019 Oct-Dec

7.  Comparison of Two Tonometers in the Evaluation of 24-Hour Intraocular Pressure and Mean Ocular Perfusion Pressure in Patients with Thyroid-Associated Ophthalmopathy.

Authors:  Weijie Liu; Yao Zhou; Xiaozhou Hu; Haochen Jin; Jie Ye; Mingna Xu; Zihui Liu; Wencan Wu; Yunhai Tu
Journal:  J Ophthalmol       Date:  2022-04-22       Impact factor: 1.974

8.  Correlation Analysis between Intraocular Pressure and Extraocular Muscles Based on Orbital Magnetic Resonance T2 Mapping in Thyroid-Associated Ophthalmopathy Patients.

Authors:  Ban Luo; Wei Wang; Xinyu Li; Hong Zhang; Yaoli Zhang; Weikun Hu
Journal:  J Clin Med       Date:  2022-07-08       Impact factor: 4.964

9.  Glucocorticoid therapy reduces ocular hypertension in active moderate-severe thyroid-associated orbitopathy.

Authors:  Chengyang Tang; Liang Liang; Xiaoya Zheng; Hong Hu; Chun Liu; Jian Long
Journal:  BMC Endocr Disord       Date:  2022-09-23       Impact factor: 3.263

Review 10.  The Application of a Contact Lens Sensor in Detecting 24-Hour Intraocular Pressure-Related Patterns.

Authors:  Sarah C Xu; Angela C Gauthier; Ji Liu
Journal:  J Ophthalmol       Date:  2016-07-25       Impact factor: 1.909

  10 in total