| Literature DB >> 2513116 |
A Medina1, A Bethencourt, E Olalla, I Coello, E Hernandez, M Trillo, J Goicolea, F Melián, E Laraudogoitia, F Jimenez.
Abstract
Balloon valvuloplasty was used in the operating room on 7 patients to visually assess the valvular changes induced by inflation of a balloon catheter. All patients had typical pulmonary valve stenosis and an associated cardiac condition which necessitated surgery. Of 23 fused commissures present, 21 were successfully opened with a single balloon inflation. In 2 patients, damage to the leaflets was observed. In 1 patient there was partial detachment and in the other a small tear was noted at the margin of one leaflet. These intraoperative results may be similar to the results obtained with percutaneous balloon valvuloplasty.Entities:
Mesh:
Year: 1989 PMID: 2513116 DOI: 10.1007/bf02577153
Source DB: PubMed Journal: Cardiovasc Intervent Radiol ISSN: 0174-1551 Impact factor: 2.740