Contemporary systematic review and meta-analysis of early outcomes with percutaneous treatment for infrapopliteal atherosclerotic disease.

Mahmood K Razavi1, Jihad A Mustapha2, Larry E Miller3.   

Abstract

PURPOSE: The need for specialty devices to improve the technical outcome of endovascular interventions is dependent on the rate of early failure in such procedures. This meta-analysis assessed procedural outcomes of such interventions to elucidate the rate of early procedural failures and the need for such specialty devices.
MATERIALS AND METHODS: MEDLINE and EMBASE were searched for contemporary studies (2000-2012) reporting procedural or short-term outcomes for revascularization of infrapopliteal atherosclerotic lesions. A random-effects metaanalysis was performed, which included post hoc comparisons among treatment groups.
RESULTS: A total of 42 studies with 52 treatment arms representing 3,660 unique patients were included. Technical success rates were higher with bare metal stents (BMSs; 98.6%) than with atherectomy (92.2%; P < .05) or percutaneous transluminal angioplasty (PTA; 91.2%; P = .01), and higher with drug-eluting stents (DESs) than with PTA (P < .001). DES use had higher primary patency rates than atherectomy (P < .05), BMS use (P < .001), and PTA (P < .01). The 30-day rate of target lesion revascularization was significantly higher with PTA (8.1%) than with BMSs (2.2%; P < .05) and DESs (1.1%; P < .05). Thirty-day rates of major unplanned amputation (range, 1.5%-4.4%) and mortality (range, 0.9%-3.3%) were comparable among treatment groups. Significant heterogeneity among studies was noted for most PTA outcomes. Publication bias was evident for most PTA and DES outcomes.
CONCLUSIONS: Early failure of percutaneous therapies in patients with infrapopliteal atherosclerotic lesions is device- and technique-dependent. Specialty devices designed to reduce technical failure rates may therefore be of benefit in this selected group of patients. Study results are confounded by inconsistent data reporting, heterogeneity of treatment effects, and publication bias.
Copyright © 2014 SIR. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25130307     DOI: 10.1016/j.jvir.2014.06.018

Source DB:  PubMed          Journal:  J Vasc Interv Radiol        ISSN: 1051-0443            Impact factor:   3.464


  2 in total

1.  Twelve-Month Results of Tack-Optimized Balloon Angioplasty Using the Tack Endovascular System in Below-the-Knee Arteries (TOBA II BTK).

Authors:  Patrick J Geraghty; George L Adams; Andrej Schmidt; Michael Lichtenberg; Christian Wissgott; Ehrin J Armstrong; Klaus Hertting
Journal:  J Endovasc Ther       Date:  2020-08       Impact factor: 3.487

2.  Prevention of in-stent restenosis with endothelial progenitor cell (EPC) capture stent placement combined with regional EPC transplantation: An atherosclerotic rabbit model.

Authors:  You-Hua Huang; Qiang Xu; Tao Shen; Jian-Ke Li; Jing-Yu Sheng; Hong-Jian Shi
Journal:  Cardiol J       Date:  2018-04-03       Impact factor: 2.737

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.