Literature DB >> 25129192

Direct digital radiograph. Technicians role in obtaining good images.

Mawya A Khafaji1, Sarah K Hagi.   

Abstract

OBJECTIVES: To determine the rejected rate of direct digital radiography (DRs) in our hospital, benchmark it with other institutes, and explore the causes of rejection.
METHODS: Data were collected between June 2012 and May 2013 at King Abdulaziz University Hospital, Jeddah, Kingdom of Saudi Arabia. The rejected analysis was registered in the system, which is a built in software. Reasons for rejection could not be deleted, and no further imaging is allowed for the same patient without reporting the reason for rejection. Reasons for rejection are predefined by the machine.
RESULTS: Of 89,797 images that were acquired, 13,371 were rejected, with a rejection rate of 15%. Positioning errors were the main reason for rejection, followed by artifact 28.5%, and motion 17.1%. As for body parts pelvis, abdomen, spine, and knee were recorded as rejected with higher rates than the average.
CONCLUSION: This study has shown a number of unnecessary repeated imaging of patients. In addition, reject analysis in DR is proven to be an indicator for quality in imaging, the reasons of rejection that have high percentage for occurrence should be given more focus during patients scan.

Entities:  

Mesh:

Year:  2014        PMID: 25129192

Source DB:  PubMed          Journal:  Saudi Med J        ISSN: 0379-5284            Impact factor:   1.484


  1 in total

1.  Educational Module Intervention for Radiographers to Reduce Repetition Rate of Routine Digital Chest Radiography in Makkah Region of Saudi Arabia Tertiary Hospitals: Protocol of a Quasi-Experimental Study.

Authors:  Rosliza Abdul Manaf; Abdullah A Almalki; Muhamad Hanafiah Juni; Hayati Kadir Shahar; Noramaliza Mohd Noor; Abdelsafi Gabbad
Journal:  JMIR Res Protoc       Date:  2017-09-26
  1 in total