Literature DB >> 25126040

Assessing and predicting the likelihood of interventions during routine annual follow-up visits for management of obstructive sleep.

Srikant Nannapaneni1, Timothy I Morgenthaler2, Kannan Ramar2.   

Abstract

STUDY
OBJECTIVES: Patients with obstructive sleep apnea (OSA) on established positive airway pressure (PAP) treatment are often advised routine annual follow-up visits to assess ongoing effectiveness and address problems associated with therapy. This study evaluates the clinical utility of annual face-to-face follow-up visits.
DESIGN: We performed a retrospective chart review of OSA patients on PAP who had completed a routine annual follow-up visit. Demographics, polysomnography, PAP compliance, Epworth Sleepiness Scale (ESS), subjective complaints (efficacy and interface issues, equipment malfunction, prescription renewal), objective findings (efficacy or leak issues, equipment problems), and visit-specific interventions were recorded. We determined relationships between patient provided information and likelihood of therapeutic versus administrative interventions.
SETTING: Academic sleep center. MEASUREMENTS AND
RESULTS: Among 716 patients who met study criteria, we abstracted data on 180 randomly selected patients. On multivariate analyses, only subjective complaints or objective findings by providers were associated with a therapeutic intervention (p < 0.0001). Though most patients (55 of 63 patients, 87.3%) who required therapeutic interventions had objective findings, without subjective complaints, the odds of such findings were only 0.12 (95% CI = 0.06-0.24, p < 0.0001). Without subjective complaints, the likelihood of a therapeutic intervention was 0.07 (95% CI = 0.03-0.15, p < 0.001).
CONCLUSION: Our data suggests that in the absence of a subjective complaint, an annual follow-up is more likely to require administrative rather than face-to-face clinical intervention. Designing a clinic model to account for this might reduce resource utilization. However, the value and optimal timing of "routine" annual follow-up visits requires further evaluation.

Entities:  

Keywords:  CPAP; clinic visits; complaints; follow-up; obstructive sleep apnea

Mesh:

Year:  2014        PMID: 25126040      PMCID: PMC4106948          DOI: 10.5664/jcsm.3972

Source DB:  PubMed          Journal:  J Clin Sleep Med        ISSN: 1550-9389            Impact factor:   4.062


  14 in total

Review 1.  Continuous positive airways pressure for obstructive sleep apnoea in adults.

Authors:  T L Giles; T J Lasserson; B J Smith; J White; J Wright; C J Cates
Journal:  Cochrane Database Syst Rev       Date:  2006-01-25

2.  Repeated split sample validation to assess logistic regression and recursive partitioning: an application to the prediction of cognitive impairment.

Authors:  Kenneth E James; Roberta F White; Helena C Kraemer
Journal:  Stat Med       Date:  2005-10-15       Impact factor: 2.373

3.  Long-term therapy with continuous positive airway pressure in obstructive sleep apnea: adherence, side effects and predictors of withdrawal - a 'real-life' study.

Authors:  Wolfgang Galetke; Letizia Puzzo; Christina Priegnitz; Norbert Anduleit; Winfried J Randerath
Journal:  Respiration       Date:  2011-03-04       Impact factor: 3.580

4.  Predictors of long-term compliance with continuous positive airway pressure.

Authors:  Malcolm Kohler; Debbie Smith; Victoria Tippett; John R Stradling
Journal:  Thorax       Date:  2010-09       Impact factor: 9.139

5.  Long-term compliance to continuous positive airway pressure therapy (nCPAP) set up during a split-night polysomnography.

Authors:  B Fleury; D Rakotonanahary; A D Tehindrazanarivelo; C Hausser-Hauw; B Lebeau
Journal:  Sleep       Date:  1994-09       Impact factor: 5.849

6.  Compliance with CPAP therapy in patients with the sleep apnoea/hypopnoea syndrome.

Authors:  H M Engleman; S E Martin; N J Douglas
Journal:  Thorax       Date:  1994-03       Impact factor: 9.139

7.  Side effects of nasal continuous positive airway pressure in sleep apnea syndrome. Study of 193 patients in two French sleep centers.

Authors:  J L Pépin; P Leger; D Veale; B Langevin; D Robert; P Lévy
Journal:  Chest       Date:  1995-02       Impact factor: 9.410

8.  Practice parameters for the use of continuous and bilevel positive airway pressure devices to treat adult patients with sleep-related breathing disorders.

Authors:  Clete A Kushida; Michael R Littner; Max Hirshkowitz; Timothy I Morgenthaler; Cathy A Alessi; Dennis Bailey; Brian Boehlecke; Terry M Brown; Jack Coleman; Leah Friedman; Sheldon Kapen; Vishesh K Kapur; Milton Kramer; Teofilo Lee-Chiong; Judith Owens; Jeffrey P Pancer; Todd J Swick; Merrill S Wise
Journal:  Sleep       Date:  2006-03       Impact factor: 5.849

Review 9.  Evaluation of positive airway pressure treatment for sleep related breathing disorders in adults.

Authors:  Peter Gay; Terri Weaver; Daniel Loube; Conrad Iber
Journal:  Sleep       Date:  2006-03       Impact factor: 5.849

10.  Compliance and side effects in sleep apnea patients treated with nasal continuous positive airway pressure.

Authors:  G Nino-Murcia; C C McCann; D L Bliwise; C Guilleminault; W C Dement
Journal:  West J Med       Date:  1989-02
View more
  1 in total

1.  Symptoms During CPAP Therapy Are the Major Reason for Contacting the Sleep Unit Between Two Routine Contacts.

Authors:  Heidi Avellan-Hietanen; Pirkko Brander; Adel Bachour
Journal:  J Clin Sleep Med       Date:  2019-01-15       Impact factor: 4.062

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.