Literature DB >> 25125394

The development of a high-throughput measurement method of octanol/water distribution coefficient based on hollow fiber membrane solvent microextraction technique.

James J Bao1, Xiaojing Liu1, Yong Zhang1, Youxin Li2.   

Abstract

This paper describes the development of a novel high-throughput hollow fiber membrane solvent microextraction technique for the simultaneous measurement of the octanol/water distribution coefficient (logD) for organic compounds such as drugs. The method is based on a designed system, which consists of a 96-well plate modified with 96 hollow fiber membrane tubes and a matching lid with 96 center holes and 96 side holes distributing in 96 grids. Each center hole was glued with a sealed on one end hollow fiber membrane tube, which is used to separate the aqueous phase from the octanol phase. A needle, such as microsyringe or automatic sampler, can be directly inserted into the membrane tube to deposit octanol as the accepted phase or take out the mixture of the octanol and the drug. Each side hole is filled with aqueous phase and could freely take in/out solvent as the donor phase from the outside of the hollow fiber membranes. The logD can be calculated by measuring the drug concentration in each phase after extraction equilibrium. After a comprehensive comparison, the polytetrafluoroethylene hollow fiber with the thickness of 210 μm, an extraction time of 300 min, a temperature of 25 °C and atmospheric pressure without stirring are selected for the high throughput measurement. The correlation coefficient of the linear fit of the logD values of five drugs determined by our system to reference values is 0.9954, showed a nice accurate. The -8.9% intra-day and -4.4% inter-day precision of logD for metronidazole indicates a good precision. In addition, the logD values of eight drugs were simultaneously and successfully measured, which indicated that the 96 throughput measure method of logD value was accurate, precise, reliable and useful for high throughput screening.
Copyright © 2014 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Drug screening; High-throughput; Hollow fiber membrane; Octanol/water distribution coefficient; Solvent microextraction

Mesh:

Substances:

Year:  2014        PMID: 25125394     DOI: 10.1016/j.jchromb.2014.07.020

Source DB:  PubMed          Journal:  J Chromatogr B Analyt Technol Biomed Life Sci        ISSN: 1570-0232            Impact factor:   3.205


  1 in total

1.  Justification of disintegration testing beyond current FDA criteria using in vitro and in silico models.

Authors:  Lukas Uebbing; Lukas Klumpp; Gregory K Webster; Raimar Löbenberg
Journal:  Drug Des Devel Ther       Date:  2017-04-11       Impact factor: 4.162

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.