Abstract

BACKGROUND: Groin dissection is commonly performed in patients with lower limb malignant conditions such as malignant melanoma, vulvar, penile, anal and scrotal carcinomas with an associated high complication rate. Numerous surgical strategies have been suggested to reduce morbidity. We aimed to systematically review one of those methods - fibrin sealant (FS) - in comparison to standard closure (SC) in reducing postoperative morbidity from groin dissection.
METHODS: A systematic search of the literature, study selection and data extraction using an independent screening process, assessment of risk of bias and statistical data analysis was performed. Only randomised controlled trials (RCTs) comparing fibrin sealant to standard care in patients with malignant disease undergoing groin dissection reporting at least one outcome measure relating to postoperative complications were included in the review.
RESULTS: A total of 6 RCTs were included. There were no statistically significant differences in postoperative surgical site infection (SSI) rates between FS and SC. The overall incidence of wound infection in the FS group was 32% (43/133) compared to 34% (45/132) in the SC group. (Pooled risk ratio = 0.0.94 [0.68, 1.32]; 95% CI; P = 0.74). The incidence of seroma for the FS group (30/133) and the SC group (30/132) did not differ (Pooled risk ratio = 1.03 [0.67, 1.58]; 95% CI; P value = 0.90). Complication rates were similar between groups.
CONCLUSION: Based on current evidence, fibrin sealant does not significantly reduce morbidity in patients undergoing groin dissection for the management of malignant disease when compared to standard closure techniques.
Copyright © 2014 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Fibrin sealant; Groin dissection; Malignant disease; Postoperative morbidity; Standard closure

Mesh:

Substances:

Year:  2014        PMID: 25125341     DOI: 10.1016/j.ejso.2014.07.034

Source DB:  PubMed          Journal:  Eur J Surg Oncol        ISSN: 0748-7983            Impact factor:   4.424


  2 in total

Review 1.  Heterologous fibrin sealant derived from snake venom: from bench to bedside - an overview.

Authors:  Rui Seabra Ferreira; Luciana Curtolo de Barros; Luciana Patrícia Fernandes Abbade; Silvia Regina Catharino Sartori Barraviera; Maria Regina Cavariani Silvares; Leticia Gomes de Pontes; Lucilene Delazari Dos Santos; Benedito Barraviera
Journal:  J Venom Anim Toxins Incl Trop Dis       Date:  2017-04-04

2.  A Novel Use of Tisseel in the Setting of Uncontrolled Bleeding in a Thrombocytopenic Patient With Idiopathic Thrombocytopenia.

Authors:  John S Fisher; Ricardo Gonzalez; Philippe E Spiess
Journal:  Urol Case Rep       Date:  2015-10-31
  2 in total