Literature DB >> 25118639

[Subcutaneous emphysema following non-surgical peri-implantitis therapy using an air abrasive device: a case report].

Mario Bassetti1, Renzo Bassetti2, Anton Sculean1, Giovanni E Salvi1.   

Abstract

Subcutaneous emphysema are rare complications in periodontology. In most cases, they resolve spontaneously. However, air might disperse into deeper facial spaces causing life-threatening complications such as compression of the tracheobronchial tree or the development of pneumomediastinum. Moreover, microorganisms might spread from the oral cavity into deeper spaces. Hence, rapid diagnosis of subcutaneous emphysema is important. Characteristic signs are both a shiftable swelling and a crepitation. In this case report, the case of a 69-year old man with a subcutaneous emphysema immediately after peri-implantitis therapy with the use of a glycine-based powder air-polishing device is described. Following therapy, air accumulated in the left side of the face. Seven days after non-surgical peri-implantitis therapy, the patient was asymptomatic with complete resolution of the emphysema.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25118639

Source DB:  PubMed          Journal:  Swiss Dent J        ISSN: 2296-6498


  5 in total

1.  Pneumocephalus as result of nonsurgical peri-implantitis treatment with an air-polishing device for submucosal debridement-A case report.

Authors:  Corinna Bruckmann; Lukas Bruckmann; André Gahleitner; Andreas Stavropoulos; Kristina Bertl
Journal:  Clin Exp Dent Res       Date:  2022-05-03

2.  Decontamination of multispecies oral biofilm from rough implant surface by airflow with glycine.

Authors:  Kyla Leung; Jiarui Bi; Georgios Giannelis; Gethin Owen; Hannu Larjava
Journal:  Clin Exp Dent Res       Date:  2021-10-26

3.  Subcutaneous Facial Emphysema Following Open-Flap Air-Powder Abrasive Debridement for Peri-Implantitis: A Case Report and an Overview.

Authors:  Gerardo La Monaca; Nicola Pranno; Susanna Annibali; Iole Vozza; Maria Paola Cristalli
Journal:  Int J Environ Res Public Health       Date:  2021-12-16       Impact factor: 3.390

4.  The Effects of Ultrasonic Scaling and Air-Abrasive Powders on the Decontamination of 9 Implant-Abutment Surfaces: Scanning Electron Analysis and In Vitro Study.

Authors:  Francesco Gianfreda; Patrizio Bollero; Maurizio Muzzi; Andrea Di Giulio; Eleonora Nicolai; Luigi Canullo
Journal:  Dent J (Basel)       Date:  2022-03-01

5.  Emphysema following air-powder abrasive treatment for peri-implantitis.

Authors:  Sung-Tak Lee; Malavika Geetha Subu; Tae-Geon Kwon
Journal:  Maxillofac Plast Reconstr Surg       Date:  2018-05-13
  5 in total