Literature DB >> 25117890

Classroom carbon dioxide concentration, school attendance, and educational attainment.

Santosh Gaihre1, Sean Semple, Janice Miller, Shona Fielding, Steve Turner.   

Abstract

BACKGROUND: We tested the hypothesis that classroom carbon dioxide (CO2 ) concentration is inversely related to child school attendance and educational attainment.
METHODS: Concentrations of CO2 were measured over a 3-5 day period in 60 naturally ventilated classrooms of primary school children in Scotland. Concentrations of CO2 were related to the class average annual attendance and proportions attaining a national standard for reading, writing, and numeracy, adjusted for socioeconomic status and class size.
RESULTS: The median (interquartile range, IQR) CO2 concentration averaged over the school day was 1086 ppm (922, 1310). In the model, Time Weighted Average CO2 concentrations were inversely associated with school attendance but not academic attainments. An increase of 100 ppm CO2 was associated with a reduced annual attendance of 0.2% (0.04, 0.4) roughly equivalent to 1 half day of school per annum, assuming schools are open on 190 days per year. Indoor temperature and relative humidity were not related to attendance or academic attainment.
CONCLUSIONS: Inadequate classroom ventilation, as evidenced by CO2 concentration exceeding 1000 ppm, is not uncommon and may be associated with reduced school attendance. A relationship between inadequate classroom ventilation and adverse health outcomes in children may be present and this needs to be explored.
© 2014, American School Health Association.

Entities:  

Keywords:  academic performance; carbon dioxide; indoor air quality; school absence; schools; temperature

Mesh:

Substances:

Year:  2014        PMID: 25117890     DOI: 10.1111/josh.12183

Source DB:  PubMed          Journal:  J Sch Health        ISSN: 0022-4391            Impact factor:   2.118


  7 in total

1.  Building and indoor environmental quality assessment of Nigerian primary schools: A pilot study.

Authors:  Oluyemi Toyinbo; Wanda Phipatanakul; Richard Shaughnessy; Ulla Haverinen-Shaughnessy
Journal:  Indoor Air       Date:  2019-03-20       Impact factor: 5.770

Review 2.  Carbon dioxide generation rates for building occupants.

Authors:  A Persily; L de Jonge
Journal:  Indoor Air       Date:  2017-04-27       Impact factor: 5.770

3.  Review and Extension of CO₂-Based Methods to Determine Ventilation Rates with Application to School Classrooms.

Authors:  Stuart Batterman
Journal:  Int J Environ Res Public Health       Date:  2017-02-04       Impact factor: 3.390

4.  The Adverse Associations of Classrooms' Indoor Air Quality and Thermal Comfort Conditions on Students' Illness Related Absenteeism between Heating and Non-Heating Seasons-A Pilot Study.

Authors:  Shihan Deng; Bin Zou; Josephine Lau
Journal:  Int J Environ Res Public Health       Date:  2021-02-05       Impact factor: 3.390

5.  Tuberculosis: First in Flight.

Authors:  Kevin P Fennelly; Leonardo Martinez; Anna Maria Mandalakas
Journal:  Am J Respir Crit Care Med       Date:  2022-02-01       Impact factor: 21.405

6.  Indoor environmental quality and learning outcomes: protocol on large-scale sensor deployment in schools.

Authors:  Juan Palacios Temprano; Piet Eichholtz; Maartje Willeboordse; Nils Kok
Journal:  BMJ Open       Date:  2020-03-16       Impact factor: 2.692

7.  Workplace exposure to carbon dioxide during routine laparoscopy - is it safe?

Authors:  Malin Af Petersens; Fritiof Andersson Fenger-Krog; Jan G Jakobsson
Journal:  F1000Res       Date:  2020-06-08
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.