Observer Variability in Sonographic Measurement of Kidney Sizes among Children in Benin-City, Nigeria.

C U Eze2, C U Eze2, T T Marchie3, C C Ohagwu4, K Ochie2.   

Abstract

AIM: To assess the level of inconsistency in replicating sonographic kidney size measurements in a population of healthy Nigerian children. SUBJECTS AND METHODS: In this prospective cross-sectional study, convenience sampling technique was used to select a sample of Nigerian children. Both consent from participants and ethical approval from the local authority were obtained before the study commenced. Three radiologists carried out the replicate sonographic measurements using a DP-1100 mechanical sector scanner with a 3.5 MHz convex probe. All examinations were done with subjects in the supine oblique position. Longitudinal and transverse scans were performed. Renal lengths and widths were measured from the longitudinal scans while thickness was measured from the transverse scans. Renal volumes were calculated with the ellipsoid formula. Analysis of variance, Student's t-test, Pearson's correlation coefficient and z-test were used to test the statistical significance of results. SPSS version 17.0 was used in the analysis of results while statistical significance of all results was tested at p < 0.05.
RESULTS: Mean intra-observer measurement errors in replicate sonographic measurements of kidney sizes ranged from 0.36-0.43 cm, 0.22-0.63 cm, 0.37-0.52 cm and 5.93-9.62 ml for kidney length, width, thickness and volume, respectively. Mean inter-observer measurement errors were in the range of 0.29-0.48 cm, 0.18-0.23 cm, 0.34-1.82 cm and 5.92-7.28 ml for length, width, thickness and volume, respectively. Mean intra-observer errors were not statistically significant (p < 0.05) but mean inter-observer errors were (p < 0.05). Differences in all measurement errors of right and left kidney length, width, thickness and volume were not statistically significant (p > 0.05). Measurement errors correlated weakly with kidney sizes. Observer errors in renal length were not significantly different from what was reported among Caucasians (p > 0.05) whereas that of volume was (p < 0.05).
CONCLUSION: Errors in replicate sonographic kidney size measurements obtained by a single observer were less than errors in the same measurements by different observers; therefore, replicate sonographic measurements by a single observer were more consistent in this population.

Entities:  

Year:  2013        PMID: 25117387     DOI: 10.7727/wimj.2012.262

Source DB:  PubMed          Journal:  West Indian Med J        ISSN: 0043-3144            Impact factor:   0.171


  3 in total

1.  Measurement and Estimation of Renal Size by Computed Tomography in Korean Children.

Authors:  Chan Won Park; Nali Yu; Sin Weon Yun; Soo Ahn Chae; Na Mi Lee; Dae Yong Yi; Young Bae Choi; In Seok Lim
Journal:  J Korean Med Sci       Date:  2017-03       Impact factor: 2.153

2.  Sonographic Portal Vein Biometry in Apparently Healthy Children in Northeastern Nigeria.

Authors:  Geofery Luntsi; Ramatu Danjuma Umar; Chigozie Nwobi Ivor; Joseph Dlama Zira; Ahmed Ahidjo
Journal:  J Med Ultrasound       Date:  2019-05-20

3.  Reply to Comment on Sonographic Portal Vein Biometry among Apparently Healthy Children in Northeastern Nigeria.

Authors:  Geofery Luntsi; Kalu Ochie
Journal:  J Med Ultrasound       Date:  2020-08-15
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.