Literature DB >> 25112454

Navigated three-dimensional T1-weighted gradient-echo sequence for gadoxetic acid liver magnetic resonance imaging in patients with limited breath-holding capacity.

Jeong Hee Yoon1, Jeong Min Lee, Eun Sun Lee, Jeehyun Baek, Sangwoo Lee, Yuji Iwadate, Joon Koo Han, Byung Ihn Choi.   

Abstract

PURPOSE: To determine whether a navigator-gated three-dimensional T1-weighted gradient-echo sequence (T1W-GRE, navigated LAVA) can improve diagnostic performance for the detection of focal liver lesions (FLLs) compared to standard breath-hold (BH) T1W-GRE breath-hold LAVA (BH-LAVA) during the hepatobiliary phase (HBP) of gadoxetic acid liver magnetic resonance imaging (MRI) in patients with limited breath-holding capacity.
MATERIALS AND METHODS: This retrospective study was approved by our institutional review board and the requirement for informed consent was waived. We included 372 patients who underwent liver MRI including both navigated LAVA and BH-LAVA sequences. Overall image quality of the two HBP image sets was compared. In patients with limited breath-holding capacity, diagnostic performances in detecting FLLs on the two HBP images were compared using jackknife-alternative free-response receiver-operating characteristic (JAFROC) analysis by two reviewers.
RESULTS: There were 13 cases (13/372; 3.5%) of image acquisition failure using the navigated LAVA sequence due to severe irregular breathing, and 50 of 359 patients had limited breath-holding capacity. In these patients, overall image quality of navigated LAVA (2.78 ± 0.95) was significantly better than that of BH-LAVA (2.42 ± 0.81, P < 0.005), and both readers showed significantly higher JAFROC figure-of-merit values with navigated LAVA compared to BH-LAVA (0.94 and 0.86 in reviewer 1, respectively; 0.89 and 0.83 in reviewer 2, respectively, P < 0.005). Overall image quality of navigated LAVA was also better than that of BH-LAVA in patients with sufficient breath-holding capacity (n = 309, 3.96 ± 0.88, 3.81 ± 0.66, respectively, P < 0.001).
CONCLUSION: The navigated LAVA sequence could provide better image quality and diagnostic performance in detecting FLLs than BH-LAVA in patients with limited breath-holding capacity during HBP of gadoxetic acid MRI.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25112454     DOI: 10.1007/s00261-014-0214-x

Source DB:  PubMed          Journal:  Abdom Imaging        ISSN: 0942-8925


  6 in total

1.  DIfferential Subsampling With Cartesian Ordering With Respiratory Triggering Versus Conventional Liver Acquisition With Volume Acquisition: A Multiple Reader Preference Study.

Authors:  Brian C Allen; Wendy L Ehieli; Benjamin Wildman-Tobriner; Mohammad Chaudhry; Erol Bozdogan; Gemini Janas; James Ronald; Mustafa R Bashir
Journal:  J Comput Assist Tomogr       Date:  2019 Jul/Aug       Impact factor: 1.826

2.  A two-stage cardiac PET and late gadolinium enhancement MRI co-registration method for improved assessment of non-ischemic cardiomyopathies using integrated PET/MR.

Authors:  Zheng Zhang; Xing Chen; Qing Wan; Haiyan Wang; Na Qi; Zhiwen You; Jianmin Yuan; Lingzhi Hu; Hongwei Sun; Zhe Wang; Chenxi Hu; Jun Zhao
Journal:  Eur J Nucl Med Mol Imaging       Date:  2022-01-15       Impact factor: 10.057

Review 3.  Non-invasive diagnostic imaging of colorectal liver metastases.

Authors:  Pier Paolo Mainenti; Federica Romano; Laura Pizzuti; Sabrina Segreto; Giovanni Storto; Lorenzo Mannelli; Massimo Imbriaco; Luigi Camera; Simone Maurea
Journal:  World J Radiol       Date:  2015-07-28

4.  Utility of Stack-of-stars Acquisition for Hepatobiliary Phase Imaging without Breath-holding.

Authors:  Shintaro Ichikawa; Utaroh Motosugi; Marie-Luise Kromrey; Daiki Tamada; Tetsuya Wakayama; Kang Wang; Ty A Cashen; Ali Ersoz; Hiroshi Onishi
Journal:  Magn Reson Med Sci       Date:  2019-05-07       Impact factor: 2.471

5.  Pseudo-random Trajectory Scanning Suppresses Motion Artifacts on Gadoxetic Acid-enhanced Hepatobiliary-phase Magnetic Resonance Images.

Authors:  Yuko Nakamura; Toru Higaki; Takashi Nishihara; Kuniaki Harada; Masahiro Takizawa; Yoshitaka Bito; Keigo Narita; Motonori Akagi; Yoshiko Matsubara; Shogo Kamioka; Yuji Akiyama; Makoto Iida; Kazuo Awai
Journal:  Magn Reson Med Sci       Date:  2019-03-18       Impact factor: 2.471

Review 6.  Rapid Imaging: Recent Advances in Abdominal MRI for Reducing Acquisition Time and Its Clinical Applications.

Authors:  Jeong Hee Yoon; Marcel Dominik Nickel; Johannes M Peeters; Jeong Min Lee
Journal:  Korean J Radiol       Date:  2019-12       Impact factor: 3.500

  6 in total