Literature DB >> 25104462

Minimally invasive, nonendoscopic thyroidectomy: a cosmetic alternative to robotic-assisted thyroidectomy.

Cara M Govednik1, Samuel K Snyder2, Courtney E Quinn2, Saurabh Saxena2, Daniel C Jupiter2.   

Abstract

BACKGROUND: The desire to improve cosmesis has driven the introduction of robotic-assisted and video-assisted thyroidectomy techniques. We report on minimally invasive thyroidectomy (MIT) through a 2-cm incision without the added need for video assistance and hypothesize similar clinical results to standard open thyroidectomy.
METHODS: Between May 2012 and December 2013, 62 nonendoscopic MIT were evaluated for demographics, clinical outcomes, and patient satisfaction on a 1-10 scale. The results were compared with a case-matched control group who underwent conventional open thyroidectomy by the same surgeon.
RESULTS: The 124 study patients demonstrated no differences between groups for demographics or clinical outcomes except a smaller thyroid lobe in the MIT group (9.2 vs 11.7 g; P = .05). There were longer operative times in the MIT group (135.4 vs 119.6 minutes; P = .07) that were not equivalent by equivalence testing (P = .534). In MIT patients, transient recurrent laryngeal nerve injury occurred per nerves at risk (1.1% vs 3.4%; P = .62) with no permanent injuries in either group. There was no difference in symptomatic hypocalcemia (9.7% vs 11.3%; P = .77) and postoperative hematoma (0% vs 3.2%; P = .50). On follow-up, the measured MIT scar was significantly shorter (2.22 vs 3.98 cm; P < .00001), which resulted in significantly improved cosmetic satisfaction ratings (9.56 vs 8.66; P = .03).
CONCLUSION: In selected patients, MIT through a 2-cm incision without endoscopic assistance is a safe alternative to standard open thyroidectomy in the hands of an experienced endocrine surgeon. The operating time is slightly increased, but clinical results are equivalent and patient satisfaction is significantly improved.
Copyright © 2014 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2014        PMID: 25104462     DOI: 10.1016/j.surg.2014.06.056

Source DB:  PubMed          Journal:  Surgery        ISSN: 0039-6060            Impact factor:   3.982


  2 in total

Review 1.  [Alternative approaches in thyroid surgery].

Authors:  E Maurer; S Wächter; D K Bartsch
Journal:  Chirurg       Date:  2017-08       Impact factor: 0.955

2.  Comparison Between the Protector™ Laryngeal Mask Airway and the Endotracheal Tube for Minimally Invasive Thyroid and Parathyroid Surgery.

Authors:  Georgios Kotsovolis; Ioannis Pliakos; Stavros Panidis; Dimitrios Gkinas; Theodosios Papavramidis
Journal:  World J Surg       Date:  2019-11       Impact factor: 3.352

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.