Literature DB >> 25104416

Numerical nonwavefront-guided algorithm for expansion or recentration of the optical zone.

Samuel Arba Mosquera, Shwetabh Verma.   

Abstract

Complications may arise due to the decentered ablations during refractive surgery, resulting from human or mechanical errors. Decentration may cause over-/under-corrections, with patients complaining about seeing glares and halos after the procedure. Customized wavefront-guided treatments are often used to design retreatment procedures. However, due to the limitations of wavefront sensors in precisely measuring very large aberrations, some extreme cases may suffer when retreated with wavefront-guided treatments. We propose a simple and inexpensive numerical (nonwavefront-guided) algorithm to recenter the optical zone (OZ) and to correct the refractive error with minimal tissue removal. Due to its tissue-saving capabilities, this method can benefit patients with critical residual corneal thickness. Based on the reconstruction of ablation achieved in the first surgical procedure, we calculate a target ablation (by manipulating the achieved OZ) with adequate centration and an OZ sufficient enough to envelope the achieved ablation. The net ablation map for the retreatment procedure is calculated from the achieved and target ablations and is suitable to expand, recenter, and modulate the lower-order refractive components in a retreatment procedure. The results of our simulations suggest minimal tissue removal with OZ centration and expansion. Enlarging the OZ implies correcting spherical aberrations, whereas inducing centration implies correcting coma. This method shows the potential to improve visual outcomes in extreme cases of retreatment, possibly serving as an uncomplicated and inexpensive alternative to wavefront-guided retreatments.

Entities:  

Mesh:

Year:  2014        PMID: 25104416     DOI: 10.1117/1.JBO.19.8.088001

Source DB:  PubMed          Journal:  J Biomed Opt        ISSN: 1083-3668            Impact factor:   3.170


  3 in total

1.  Centration of myopic refractive ablation: should we center treatment on the pupil or the visual axis?

Authors:  Gilad Rabina; Michael Mimouni; Jacqueline Slomovic; Nir Sorkin; Achia Nemet; Igor Kaiserman
Journal:  Lasers Med Sci       Date:  2021-06-29       Impact factor: 3.161

Review 2.  Errors in Treatment of Lower-order Aberrations and Induction of Higher-order Aberrations in Laser Refractive Surgery.

Authors:  Brad E Kligman; Brandon J Baartman; William J Dupps
Journal:  Int Ophthalmol Clin       Date:  2016

3.  Centration axis in refractive surgery.

Authors:  Samuel Arba Mosquera; Shwetabh Verma; Colm McAlinden
Journal:  Eye Vis (Lond)       Date:  2015-02-24
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.