PURPOSE: To present treatment of a juxtarenal aneurysm using the Nellix endovascular aneurysm sealing system (EVAS) and a chimney stent. CASE REPORT: A 79-year-old woman was diagnosed with a 6-cm juxtarenal aneurysm. Standard endovascular aneurysm repair was not possible due to lack of an adequate infrarenal landing zone, and poor iliac access and angulated visceral aortic branches precluded a custom-made fenestrated solution. The patient was not a suitable candidate for open surgery due to significant comorbidity, so she underwent successful endovascular aneurysm repair with the Nellix EVAS system and a renal chimney stent. Follow-up imaging at 6 months showed a sealed aneurysm sac and patent renal chimney stent.
CONCLUSION: The Nellix EVAS system obliterates the aneurysm sac using polymer-filled endobags. The ability of the endobags to conform to adjacent structures may offer advantages over conventional endografts when combined with parallel grafts designed to treat juxtarenal aneurysms.

Entities:  

Keywords:  abdominal aortic aneurysm; balloon-expandable stent; chimney graft; endovascular aneurysm repair; juxtarenal aneurysm; renal artery; stent-graft

Mesh:

Year:  2014        PMID: 25101582     DOI: 10.1583/14-4698R.1

Source DB:  PubMed          Journal:  J Endovasc Ther        ISSN: 1526-6028            Impact factor:   3.487


  4 in total

1.  Endovascular aneurysm sealing for the treatment of ruptured abdominal aortic aneurysms.

Authors:  Jorg L de Bruin; Jack R W Brownrigg; Alan Karthikesalingam; Benjamin O Patterson; Peter J E Holt; Robert J Hinchliffe; Robert A Morgan; Ian M Loftus; Matthew M Thompson
Journal:  J Endovasc Ther       Date:  2015-04-22       Impact factor: 3.487

2.  Endovascular treatment of paravisceral mycotic aneurysm: Chimmeny endovascular sealing the end of de road.

Authors:  Martin Rabellino; Pedro N Moltini; Vanesa G Di Caro; Jose G Chas; Ricardo Marenchino; Ricardo D Garcia-Monaco
Journal:  World J Cardiol       Date:  2017-07-26

3.  An in Vitro Twist Fatigue Test of Fabric Stent-Grafts Supported by Z-Stents vs. Ringed Stents.

Authors:  Jing Lin; Robert Guidoin; Jia Du; Lu Wang; Graeham Douglas; Danjie Zhu; Mark Nutley; Lygia Perron; Ze Zhang; Yvan Douville
Journal:  Materials (Basel)       Date:  2016-02-16       Impact factor: 3.623

4.  Secondary Fill Minimizes Gutter Size in Chimney EVAS Configurations In Vitro.

Authors:  Theodorus G van Schaik; Jorn P Meekel; Vincent Jongkind; Rutger J Lely; Maarten Truijers; Arjan W J Hoksbergen; Willem Wisselink; Jan D Blankensteijn; Kak Khee Yeung
Journal:  J Endovasc Ther       Date:  2018-12-21       Impact factor: 3.487

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.