Zohreh Fathi1, Marziyeh Tavalaee2, Abbas Kiani2, Mohammad Reza Deemeh3, Mehrdad Modaresi4, Mohammad Hossein Nasr-Esfahani5. 1. Department of Reproduction and Development, Reproductive Biomedicine Center, Royan Institute for Animal Biotechnology, ACECR, Isfahan, Iran ; Payame Noor University, Isfahan, Iran. 2. Department of Reproduction and Development, Reproductive Biomedicine Center, Royan Institute for Animal Biotechnology, ACECR, Isfahan, Iran. 3. Department of Reproduction and Development, Reproductive Biomedicine Center, Royan Institute for Animal Biotechnology, ACECR, Isfahan, Iran ; Isfahan Fertility and Infertility Center, Isfahan, Iran. 4. Islamic Azad University-Khorasgan Branch, Isfahan, Iran. 5. Department of Reproduction and Development, Reproductive Biomedicine Center, Royan Institute for Animal Biotechnology, ACECR, Isfahan, Iran ; Isfahan Fertility and Infertility Center, Isfahan, Iran ; Department of Embryology, Reproductive Biomedicine Research Center, Royan Institute for Reproductive Biomedicine, ACECR, Tehran, Iran.
Abstract
BACKGROUND: Chromomycin A3 (CMA3) staining, either by the slide method or fluorescence microscopy, is widely used for indirect assessment of protamine deficiency in a semen sample. Flow cytometry is the most suitable tool to improve assessment accuracy, both in terms of statistical analysis and for prevention of observer variation. This study provides a simple procedure to account for merocyanine 540 (M540) or apoptotic bodies, which result in underestimation of the percentage of CMA3 positivity, by using propidium iodide (PI) staining. Therefore, this study aims to evaluate the percentage of CMA3 by PI staining to exclude M540 bodies that prevent underestimation of CMA3 staining. MATERIALS AND METHODS: This study is an experimental study. Semen samples collected from 104 infertile men who referred to the Andrology Unit of the Isfahan Fertility and Infertility Center were initially assessed according to World Health Organization (WHO) criteria. Samples were washed twice with Ham's. Each sample was divided into two portions, a control and the other processed for density gradient centrifugation (DGC). Each portion was assessed for CMA3 staining by both the slide and flow cytometry methods. Coefficients of correlation and student t-test were carried out using the Statistical Package for the Social Studies (SPSS 11.5). RESULTS: Detection of CMA3 staining was more appropriate with fluorescence detector 3 (FL-3) rather than fluorescence detector 2 (FL-2) in the evaluation of protamine deficiency to exclude M540 bodies. CONCLUSION: This study, for the first time, provides the basis for assessment of CMA3 staining for flow cytometry. However, since the maximum excitation for CMA3 is not covered by the 488 nm laser, we recommend further experimentation using a flow cytometer with optimal excitation.
BACKGROUND:Chromomycin A3 (CMA3) staining, either by the slide method or fluorescence microscopy, is widely used for indirect assessment of protamine deficiency in a semen sample. Flow cytometry is the most suitable tool to improve assessment accuracy, both in terms of statistical analysis and for prevention of observer variation. This study provides a simple procedure to account for merocyanine 540 (M540) or apoptotic bodies, which result in underestimation of the percentage of CMA3 positivity, by using propidium iodide (PI) staining. Therefore, this study aims to evaluate the percentage of CMA3 by PI staining to exclude M540 bodies that prevent underestimation of CMA3 staining. MATERIALS AND METHODS: This study is an experimental study. Semen samples collected from 104 infertile men who referred to the Andrology Unit of the Isfahan Fertility and Infertility Center were initially assessed according to World Health Organization (WHO) criteria. Samples were washed twice with Ham's. Each sample was divided into two portions, a control and the other processed for density gradient centrifugation (DGC). Each portion was assessed for CMA3 staining by both the slide and flow cytometry methods. Coefficients of correlation and student t-test were carried out using the Statistical Package for the Social Studies (SPSS 11.5). RESULTS: Detection of CMA3 staining was more appropriate with fluorescence detector 3 (FL-3) rather than fluorescence detector 2 (FL-2) in the evaluation of protamine deficiency to exclude M540 bodies. CONCLUSION: This study, for the first time, provides the basis for assessment of CMA3 staining for flow cytometry. However, since the maximum excitation for CMA3 is not covered by the 488 nm laser, we recommend further experimentation using a flow cytometer with optimal excitation.
Daily exposure to a number of common chemicals
in the home and workplace is one of the main
reasons for infertility. Both environmental and
other causes have made infertility a pandemic phenomenon.
Therefore, understanding the precise
molecular mechanisms underlying infertility may
provide useful hints for its prevention and treatment
(1).Assessment of male infertility based upon semen
analysis as described by the World Health Organization
(WHO) guidelines only provides quantitative
and qualitative analysis rather than mechanistic
or functional information (2). In this regard,
sperm function tests are becoming an inevitable
part of the andrology laboratory. The clinical application
of each test is being evaluated. Tests such
as the sperm chromatin structural assay (SCSA), sperm chromatin dispersion test and TUNEL assay
are becoming more common as complementary
tests for semen analysis. The two former tests
are based on the susceptibility of sperm to undergo
denaturation while the latter assesses sperm DNA
fragmentation (3-5).One of the main factors affecting the susceptibility
of sperm to undergo denaturation and inevitably
DNA damage is the proper replacement of histones
with protamine during chromatin compaction in
the process of spermiogenesis (6). Protamine efficiency
can be assessed indirectly by chromomycin
A3 (CMA3), which has been shown to compete
with protamine to bind DNA (7-9). Following the
first report on the use of CMA3 for assessment
of protamine deficiency by Bianchi et al. in 1993
there have been over 1500 reports regarding the
implementation of CMA3 staining for infertility
assessment. These techniques have been based on
fluorescence microscopy (10). Flow cytometry,
compared to fluorescence microscopy or the slide
method has many advantages and a few disadvantages.
The advantages of flow cytometry include
analysis of thousands of cells within a few seconds,
providing a statistically more precise evaluation by
a reproducible technique, reducing intra-observer
variations and sperm counts based on DNA staining.
One disadvantage is the absence of direct observation
(11).In a previous study, we standardized the CMA3
staining procedure to indirectly assess semen sample
protamination by flow cytometry. Our study determined
that sperm could be assessed as fixed or
unfixed. The fluorescence microscopic procedure
utilized washed sperm samples that were fixed
prior to assessment. According to our research;
both the sperm concentration and duration of exposure
should be constant. Thus, we have proposed
that a concentration of 2 million sperm should be
stained with CMA3 solution for an optimal time
of 60 minutes. Fixed samples can be stained and
assessed later (12).A study of the literature has revealed that semen
in addition to somatic and germ cells may contain
round structures like sperm head, in different
dimensions, and are observable via light microscopy.
They are apoptotic bodies which have been
named merocyanine 540 (M540) bodies, since they
promptly stain with M540 and contain no DNA or
small quantities of fragmented DNA (13). Therefore,
M540 bodies are not labeled with nuclear
probes, such as propidium iodide (PI) or Yo-Pro-1.These properties partially locate these M540bodies
in the same region of flow cytometric dot plot (forward
and side scatter) that contain sperm samples.
Therefore, if M540 bodies are not excluded from
flow cytometric analysis the results will be underestimated
(14-16). Muratori et al. have shown
that due to the heterogeneous nature of M540, in
terms of size and density, they migrate differently
during the density gradient centrifugation (DGC)
of sperm. Thus, M540 are completely or partially
isolated during the swim up and DGC procedures
used for sperm processing (17).CMA3 is a flurochrome that can be assessed by
both fluorescence detectors 2 (FL-2) and 3 (FL-3)
and to our knowledge, the choice of detector used
when staining with CMA3 remains to be determined.
Therefore, the aim of this study is to evaluate
the percentage of CMA3 by PI staining with
the purpose of excluding M540 bodies as they prevent
underestimation of the percentage of CMA3
positivity by flow cytometery.
Materials and Methods
Sperm analysis and processing
Semen samples were collected from 104 infertile
men who referred to the Andrology Unit of
the Isfahan Fertility and Infertility Center. This
experimental study was approved by Royan Institutional
Review Board. Informed consent forms
were signed by all the individuals who provided
semen samples for this study. Samples were initially
assessed according to WHO criteria (2) and
then washed twice with Ham’s at 400g centrifugation
for 5 minutes prior to being separated into two
portions. One portion was used as a control while
the other was processed for DGC using PureSperm
(Nidacon, Gothenburg, Sweden) according
to the manufacturer’s specifications. Each portion
was assessed for CMA3 staining by both the slide
and flow cytometric methods.
Assessment of M540 bodies by merocyanine and
Yo-Pro-1
For measurement of M540 bodies, 15μl from
M540 (2.09 μM; Sigma, USA) and Yo-Pro-1 (0.01
μM; Sigma, USA) were added to the sperm suspension
and incubated at room temperature for 20
minutes in the dark. For sample analysis, a FACS
Calibur flow cytometer (Becton Dickinson, San
Jose, CA, USA) equipped with a 488 nm laser
was chosen and 10000 apparently sperm-specific events were calculated. A forward and side scatter
(FSC and SSC) gate was used to select single
sperm from debris and aggregates. Fluorescence
compensation was set by unstained sperm and
separately stained with Yo-Pro-1 and M540. Green
fluorescence from Yo-Pro-1 and red fluorescence
from M540 were collected in fluorescence detector
1 (FL-1) with a 530/30 nm band-pass filter and
FL-2 with a 585/42 nanometer (nm) band-pass
filter, respectively. Data were analyzed using BD
Cell Quest Pro and WinMDI 2.9 software.
Assessment of protamine deficiency (chromomycin
A3 staining)
CMA3 staining was assessed according to a previously
described procedure for CMA3 flow cytometry
and fluorescence microscopy (7, 12). Briefly,
the control and DGC processed samples were fixed
with Cranoy’s solution and divided into three portions.
One portion was used to prepare the smear
for fluorescence microscopy, which was stained
for 20 minutes with 100 μl of 0.25 mg/ml CMA3
solution (Sigma, USA). For flow cytometry, the
concentration of sperm was adjusted to 2 million
per ml, centrifuged and fixed with Cranoy’s solution.
The pellet was resuspeded in 200 μl of 0.25
mg/ml of CMA3 solution for 1 hour. Then, samples
were washed and used for flow cytometry and
assessed by FL-2 and FL-3. To 500 μl of the third
portion, which contained 1 million fixed sperm, 5
μl PI (1 μg/ml) was added for 10 minutes before
assessment with flow cytometry.The excitation range of CMA3 has been reported
to be between ~350 and ~500nm (maximum excitation
limitation: 430-457 nm). In this study we
use a 488 nm laser, which is at the end of the excitation
range of CMA3 that allowed us to obtain detectable
emissions in both FL-2 and FL-3. Therefore,
we recommend the results to be repeated on a
flow cytometer equipped with a laser to emit light
at around 445 nm (between 430 to 457 nm) to excite
CMA3 (18, 19).
Calculation of CMA3 based on PI staining
Following assessment of CMA3 by flow cytometry,
the number of CMA3 positive sperm in 10000
counted cells was defined. This number was divided
by the number of PI positive cells in the 10000
counted cells, multiplied by 10000 cells with the
assumption that all the counted CMA3 positive
cells were sperm. For example, the number of
CMA3 positive cells was 30% or 3000 in 10000
counted cells and the number of PI positive cells
was 95% or 9500 cells in the 10000 counted cells.
Therefore, the true number of CMA3 positive cells
would be 3160 rather than 3000 cells per 10000
counted and the true percentage of CMA3 would
be 31.6% instead of 30%.
Statistical analysis
Results are expressed as means ± SEM. For statistical
analysis, coefficients of correlation and
paired t-tests were carried out using the Statistical
Package for the Social Studies (SPSS, version.
11.5, Chicago, IL, USA) software to compare results
between different groups. A probability of
p<0.05 was considered statistically significant.
Results
Figure 1A shows the plot of M540 and Y1 staining
in semen samples (upper left are apoptotic bodies,
or the M540 positive, and Y1 negative) while Figure
1B shows the PI histogram of the same sample (PI
negative population). We assessed the correlation
between the percentage of PI negative cells and the
percentage of M540 bodies in ten semen samples
where a strong correlation was observed (r=+0.95,
p<0.001, Fig 1C). These samples were further processed
with DGC and the percentage of M540 bodies
was assessed by both M540/Y1 (Fig 1D) and
with PI (Fig 1E). The results of Figure 1F show that
DGC has isolated these M540 bodies as assessed
by both M540/Y1 and PI staining in the same ten
semen samples. In the remaining experiments we
assessed only PI as an indication for M540 bodies.
Fig 1
(A) Dot plot of M540 versus Yo-Pro-1 staining and (B) PI histogram in a semen sample. (C).
Correlation between the percentage of PI negative cells and M540 positive/ Yo-Pro-1 negative. (D)
Dot plot of M540 versus Yo-Pro-1 staining and (E) PI histogram in a processed sample by DGC. (F)
Comparison of the percentage of PI negative cells and M540 positive/ Yo-Pro-1 negative before and
after processing. Common letters are significantly different at p<0.05.
Following the above conclusion, 104 samples
were simultaneously assessed for CMA3 staining
by fluorescence microscopy and flow cytometry
by FL-2 and FL-3. Of the samples, 86 were processed
simultaneously by DGC and then assessed
for CMA3 staining. Both the processed and neat
samples have been assessed for the percentage of
PI positive or negative cells. Figure 2 shows that
in the DGC procedure, the percent of the CMA3
positive sperm decreased significantly with fluorescence
microscopy. However assessment by
flow cytometry revealed an increase in the percentage
of CMA3 positive cells post-DGC, when
FL-2 was used and a decrease in the percentage of
CMA3 positive cells when FL-3 was implemented,
irrespective of apoptotic bodies (with and without
PI). These values were only significantly different
when FL-2 was implemented without taking into
account the M540 bodies.(A) Dot plot of M540 versus Yo-Pro-1 staining and (B) PI histogram in a semen sample. (C).
Correlation between the percentage of PI negative cells and M540 positive/ Yo-Pro-1 negative. (D)
Dot plot of M540 versus Yo-Pro-1 staining and (E) PI histogram in a processed sample by DGC. (F)
Comparison of the percentage of PI negative cells and M540 positive/ Yo-Pro-1 negative before and
after processing. Common letters are significantly different at p<0.05.Comparison of the percentage of sperm with CMA3 positivity by fluorescence
microscopy and flow cytometry using fluorescence detectors 2 or 3 (FL-2 and
FL-3) in semen and DGC. Common letters are significantly different at p<0.05.Figures 3A and B show the correlations of percent
of CMA3 positivity as assessed by fluorescence
microscopy and flow cytometry using FL-2
and FL-3. A significant weak correlation was observed
between fluorescent microscopy and flow
cytometry using FL-2 (r=0.320; p=0.006) and FL-3
(r=0.273; p=0.048). However, a strong significant
correlation was observed between FL-2 and FL-3
(r=0.819 and p<0.001, Fig . 3C).
Fig 3
Correlations of the percentage of CMA3 positivity assessed by fluorescence microscopy and flow cytometry
using fluorescence detector 2 or 3 (FL-2 and FL-3).
In addition, a comparison of the mean percent of
CMA3 between the slide method and flow cytometry
using FL-2 or FL-3 showed that both flow cytometric
measurements were significantly lower than
the slide method. However, the mean FL-3 measurement
was closer to the slide method (Fig 4).
Fig 4
Comparison of the percentage of sperm with CMA3
positivity between the slide method and flow cytometry using
fluorescence detectors 2 or 3 (FL-2 and FL-3). Common letters
are significantly different at p<0.05.
Correlations of the percentage of CMA3 positivity assessed by fluorescence microscopy and flow cytometry
using fluorescence detector 2 or 3 (FL-2 and FL-3).Comparison of the percentage of sperm with CMA3
positivity between the slide method and flow cytometry using
fluorescence detectors 2 or 3 (FL-2 and FL-3). Common letters
are significantly different at p<0.05.
Discussion
The presence of over 1500 reports in the literature
emphasizes the evaluation of protamine content
by indirect CMA3 staining. Except for our recent
report on standardization and implementation of
CMA3 staining by flow cytometry in sperm (12),
there are few reports which have used CMA3 with
flow cytometry based on the microscopic or slide
method, as initially introduced by Bianchi et al. in
1993 (10). In this and our previous study we have
shown that the mean percentage positive value of
CMA3 as assessed by flow cytometry was lower
than the slide method. Additionally the mean values
were lower when assessed by FL-2 than FL-3 (Fig 4). One possible explanation that may account for
this difference could be the underestimation of the
percent of CMA3positive sperm due to the presence
of M540 bodies in semen. Therefore, in order to exclude
these bodies from our evaluation and provide
an easy procedure to account for underestimation,
we initially evaluated the role of PI staining in semen
samples prepared for CMA3 staining.The most common procedure for the assessment
of M540 bodies is the use of merocyanine along
with Y1 staining (15). In this study, we have aimed
to distinguish these bodies from sperm with PI
staining since they contain no or minute amounts
of DNA. A very strong correlation between the
percentages of PI negative events with these bodies
(M540 positive and Yo-Pro-1 negative) in
flow cytometry was shown. This suggested that
PI negative events in flow cytometry were most
likely M540 bodies (Fig 1A, B, C). This was further
verified by the fact that sperm processing reduced
their numbers and in this study both M540
positive/ Yo-Pro-1 negative and PI negative events
were reduced following sperm density gradient.
Therefore, based on these data we provided an
easy calculation method (as seen in the Materials
and Methods section) to exclude M540 bodies
from our sperm population during CMA3 assessment,
which was based on PI staining of solely
fixed semen samples.The results of this study also revealed that the
percentage CMA3 positive sperm obtained by the
slide method or microscopic procedure, despite
accounting for M540 bodies, were still significantly
greater than the flow cytometric method,
irrespective of assessment by FL-2 or FL-3 (Fig 4). As with our previous study, we obtained a very
weak correlation between the slide method and
flow cytometric procedure (Fig 3) (12). Although
the slide method has been previously assessed for
intra- and inter-observation variation with a low
coefficient of variation (20) this difference may
solely be contributed to instrumental precision.
With the instrument, a threshold is described based
on unstained samples while such precision cannot
be visually attained. Indeed, a similar observation has been previously reported for acridine orange
staining. Therefore the sperm chromatin structural
assay which is a routinely accepted clinical test
based on acridine orange staining is considered acceptable
when carried out by flow cytometry and
not by the slide method (21).In flow cytometry the mean values of CMA3 obtained,
excluding M540 bodies, are significantly
greater in FL-3 than FL-2. Despite a significant correlation
between the CMA3 assessment by FL-2 and
FL-3, figure 3A and B show a wider range of CMA3
in FL-3 than FL-2; this may suggest that variations
within a heterogeneous sample are more assessable
in FL-3. In addition, as shown in this study and well
accepted in the literature, one expects a reduction
in the percentage of CMA3 positive sperm following
DGC, even though no significance has been observed
with FL-3, in contrast to FL2. Although we
could not account for this difference between FL-2
and FL-3, despite the use of the same semen samples
for these assessments, one possible explanation
could be that FL-2 does not provide the optimal
wavelength for assessment of CMA3.Therefore,
variations within samples are more observable in
FL-3.
Conclusion
In considering the evaluation of CMA3 for assessment
of protamine deficiency, we propose the assessment
of CMA3 by flow cytometry using FL-3
and staining for PI to exclude M540 bodies, especially
in samples with oligo-astheno-teratospermia
or astheno-tratospermia where the presence of these
bodies has been reported to be high (15). Therefore,
evaluation of CMA3 staining as clinical tool by flow
cytometry awaits further research. However, we
recommend further experimentation using a flow
cytometer with optimal excitation for CMA3.
Authors: D P Evenson; L K Jost; D Marshall; M J Zinaman; E Clegg; K Purvis; P de Angelis; O P Claussen Journal: Hum Reprod Date: 1999-04 Impact factor: 6.918
Authors: Berlin Pandapotan Pardede; Muhammad Agil; Ni Wayan Kurniani Karja; Cece Sumantri; Iman Supriatna; Bambang Purwantara Journal: Vet Sci Date: 2022-03-03