Literature DB >> 25100069

Joint-specific distance thresholds for patient-specific approximations of articular cartilage modeling in the first ray of the foot.

G L S Marchelli1, W R Ledoux, V Isvilanonda, M A Ganter, D W Storti.   

Abstract

The addition of cartilage elements in a finite element model prevents bone-on-bone articulation during simulation, thus providing more accurate information about joint kinematics. We present a semi-automated method for identifying joint articulation surfaces and creating volumetric articular cartilage elements based on patient-specific bone information. The approach identifies contact surfaces based on a joint-specific, user-specified distance threshold criterion applied to a polygonized set of bones. Volumetric cartilage elements are generated using half of the minimum inter-joint distance. We present the method and then apply it to the first ray of the human foot, which includes the medial cuneiform, first metatarsal, and first proximal and distal phalanges. Distance thresholds for the first ray ranged from 3.0 to 4.25 mm depending on the joint and the desired contact surface coverage. Inter-joint distances were found and applied to the contact surfaces to generate uniformly thick cartilage models. Average inter-joint distances of 0.46, 0.72 and 0.51 mm were found for the first interphalangeal, metatarsophalangeal, and cuneometatarsal joints, respectively. The values cited are one half of the minimum inter-joint difference, as identified by the proximity algorithm. This is taken to represent the (uniform) cartilage thickness at each joint.

Entities:  

Mesh:

Year:  2014        PMID: 25100069     DOI: 10.1007/s11517-014-1179-1

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  15 in total

1.  A voxel-based formulation for contact finite element analysis.

Authors:  Nicole M Grosland; Thomas D Brown
Journal:  Comput Methods Biomech Biomed Engin       Date:  2002-02       Impact factor: 1.763

2.  A three-dimensional, anatomically detailed foot model: a foundation for a finite element simulation and means of quantifying foot-bone position.

Authors:  Daniel L A Camacho; William R Ledoux; Eric S Rohr; Bruce J Sangeorzan; Randal P Ching
Journal:  J Rehabil Res Dev       Date:  2002 May-Jun

3.  Effects of internal stress concentrations in plantar soft-tissue--A preliminary three-dimensional finite element analysis.

Authors:  Wen-Ming Chen; Taeyong Lee; Peter Vee-Sin Lee; Jin Woo Lee; Sung-Jae Lee
Journal:  Med Eng Phys       Date:  2010-02-02       Impact factor: 2.242

4.  Physical validation of a patient-specific contact finite element model of the ankle.

Authors:  Donald D Anderson; Jane K Goldsworthy; Wendy Li; M James Rudert; Yuki Tochigi; Thomas D Brown
Journal:  J Biomech       Date:  2007-04-12       Impact factor: 2.712

5.  Load transfer mechanism for different metatarsal geometries: a finite element study.

Authors:  J M García-Aznar; J Bayod; A Rosas; R Larrainzar; R García-Bógalo; M Doblaré; L F Llanos
Journal:  J Biomech Eng       Date:  2009-02       Impact factor: 2.097

6.  Effect of Achilles tendon loading on plantar fascia tension in the standing foot.

Authors:  Jason Tak-Man Cheung; Ming Zhang; Kai-Nan An
Journal:  Clin Biomech (Bristol, Avon)       Date:  2005-11-08       Impact factor: 2.063

7.  A 3-dimensional finite element model of the human foot and ankle for insole design.

Authors:  Jason Tak-Man Cheung; Ming Zhang
Journal:  Arch Phys Med Rehabil       Date:  2005-02       Impact factor: 3.966

8.  An articular cartilage contact model based on real surface geometry.

Authors:  S-K Sang-Kuy Han; Salvatore Federico; Marcelo Epstein; Walter Herzog
Journal:  J Biomech       Date:  2005-01       Impact factor: 2.712

9.  A kinematics-based method for generating cartilage maps and deformations in the multi-articulating wrist joint from CT images.

Authors:  G Elisabeta Marai; Joseph J Crisco; David H Laidlaw
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2006

10.  Custom-designed orthopedic implants evaluated using finite element analysis of patient-specific computed tomography data: femoral-component case study.

Authors:  Ola L A Harrysson; Yasser A Hosni; Jamal F Nayfeh
Journal:  BMC Musculoskelet Disord       Date:  2007-09-13       Impact factor: 2.362

View more
  1 in total

1.  Fast in silico assessment of physical stress for peripheral nerves.

Authors:  Elisabetta Giannessi; Maria Rita Stornelli; Pier Nicola Sergi
Journal:  Med Biol Eng Comput       Date:  2018-02-12       Impact factor: 2.602

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.