Literature DB >> 25099938

Comparison of respiratory function during TIVA (romifidine, ketamine, midazolam) and isoflurane anaesthesia in spontaneously breathing ponies Part I: blood gas analysis and cardiorespiratory variables.

Barbara Steblaj1, Stijn Schauvliege, Kiriaki Pavlidou, Frank Gasthuys, Ioannis Savvas, Luc Duchateau, Lidia Kowalczyk, Lidia Kowalczk, Yves Moens.   

Abstract

OBJECTIVE: To compare pulmonary function and gas exchange in ponies during maintenance of anaesthesia with isoflurane or by a total intravenous anaesthesia (TIVA) technique. STUDY
DESIGN: Experimental, cross-over study. ANIMALS: Six healthy ponies weighing mean 286 (range 233-388) ± SD 61 kg, age 13 (9-16) ± 3 years.
METHODS: The ponies were anaesthetized twice, a minimum of two weeks apart. Following sedation with romifidine [80 μg kg(-1) intravenously (IV)], anaesthesia was induced IV with midazolam (0.06 mg kg(-1)) and ketamine (2.5 mg kg(-1), then maintained either with inhaled isoflurane (Fe'Iso = 1.1 vol%) (T-ISO) or an IV infusion of romifidine (120 μg kg(-1) hour(-1)), midazolam (0.09 mg kg(-1) hour(-1) IV) and ketamine (3.3 mg kg(-1) hour(-1)) (T-TIVA). Ponies were placed in lateral recumbency. Breathing was spontaneous and Fi'O(2) 60%. After an instrumentation/stabilisation period of 30 minutes, arterial and mixed venous blood samples were taken simultaneously every 10 minutes for 60 minutes and analysed immediately. Oxygen extraction ratio (O(2)ER) and venous admixture were calculated. Tidal volume (TV), minute volume (MV), respiratory rate (f(R)), packed cell volume (PCV), arterial blood pressure and heart rate (HR) were measured and recorded. Data were analysed with mixed model anova (α = 0.05). Treatments were compared overall and at two selected time points (T30 and T60) using Bonferroni correction.
RESULTS: Arterial and mixed venous partial pressures of O(2) and CO(2), and TV were significantly lower and MV and f(R) were higher in T-TIVA compared to T-ISO. Venous admixture did not differ between treatments. O(2) R was significantly higher in T-TIVA. Mean arterial pressure was higher and HR was lower in T-TIVA compared to T-ISO. CONCLUSIONS AND CLINICAL RELEVANCE: Whilst arterial CO(2) was within an acceptable range during both protocols, the impairment of oxygenation was more pronounced with the T-TIVA evidenced by lower arterial and venous oxygen partial pressures.
© 2014 Association of Veterinary Anaesthetists and the American College of Veterinary Anesthesia and Analgesia.

Entities:  

Keywords:  TIVA; blood gases; isoflurane; oxygen extraction ratio; ponies; pulmonary function

Mesh:

Substances:

Year:  2014        PMID: 25099938     DOI: 10.1111/vaa.12167

Source DB:  PubMed          Journal:  Vet Anaesth Analg        ISSN: 1467-2987            Impact factor:   1.648


  1 in total

1.  Total intravenous anesthesia using a midazolam-ketamine-xylazine infusion in horses: 46 cases (2011-2014).

Authors:  Turi K Aarnes; Phillip Lerche; Richard M Bednarski; John A E Hubbell
Journal:  Can Vet J       Date:  2018-05       Impact factor: 1.008

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.