Safety and efficacy of ulthera in the rejuvenation of aging lower eyelids: a pivotal clinical trial.

Chang Sik Pak1, Yung Ki Lee, Jae Hoon Jeong, Ji Hoon Kim, Jae Don Seo, Chan Yeong Heo.   

Abstract

BACKGROUND: The changes in the periorbital region are among the most prominent features of the aging process in the lower eyelids. Intense focused ultrasound (IFUS), known as the Ulthera System, was designed to correct this process. The current study assessed the safety and efficacy of the Ulthera System.
METHODS: This study enrolled seven adult patients who presented from March 2011 to May 2012 for correction of lower eyelid aging by Ulthera. The subjects were treated using Ulthera 1.5 and 3.0 mm probes. The 1.5 mm probe is used to tighten of loose eyelid skin and the deep dermis, whereas the 3.0 mm probe is used to tighten the orbicularis oculi muscle and the orbital septum. The patients were evaluated for allergic reactions and other side effects. The subjects' satisfaction with clinical photographs and the degree of pain were evaluated. Moreover, orbital computed tomography (CT) and ophthalmologic examinations were performed. The study used CT both as a research tool and as a clinical score system for evaluating aging lower eyelids and performed statistical analysis.
RESULTS: Based on the CT images, the difference between the pre- and postoperative distances from the baseline (line between the most inferior point of the supraorbital rim and the most superior point of the infraorbital rim) to the most protruding point of the orbital septum was 0.51 ± 0.23 for the right eye (p < 0.001) and 0.54 ± 0.17 for the left eye (p < 0.001). The subjective score for patient satisfaction was 3.85 ± 0.69. The objective satisfaction scores reported by two blinded researchers were respectively 3.45 ± 1.69 and 3.25 ± 1.43. During the study period, no adverse events and no suspected serious adverse reactions were noted.
CONCLUSIONS: Tightening of infraorbital laxity and skin can be achieved using the Ulthera System. Patients showed a minimal pain level during treatment, and topical analgesic cream was able to manage pain during the procedure.

Entities:  

Mesh:

Year:  2014        PMID: 25099495     DOI: 10.1007/s00266-014-0383-6

Source DB:  PubMed          Journal:  Aesthetic Plast Surg        ISSN: 0364-216X            Impact factor:   2.326


  9 in total

1.  Non-invasive high-intensity focused ultrasound for UV-induced hyperpigmentation in Fitzpatrick skin types III and IV: a prospective, randomized, controlled, evaluator-blinded trial.

Authors:  Vasanop Vachiramon; Natthachat Jurairattanaporn; Sarawin Harnchoowong; Pamela Chayavichitsilp
Journal:  Lasers Med Sci       Date:  2017-11-27       Impact factor: 3.161

2.  Intra-rater reproducibility of shear wave elastography in the evaluation of facial skin.

Authors:  Łukasz Paluch; Piotr Pietruski; Bartłomiej Noszczyk; Bartłomiej Kwiek; Marcin Ambroziak
Journal:  Postepy Dermatol Alergol       Date:  2019-01-10       Impact factor: 1.837

3.  Customized Treatment Using Microfocused Ultrasound with Visualization for Optimized Patient Outcomes: A Review of Skin-tightening Energy Technologies and a Pan-Asian Adaptation of the Expert Panel's Gold Standard Consensus.

Authors:  Je-Young Park; Frank Lin; Atchima Suwanchinda; Rungsima Wanitphakdeedecha; Jonathan Yu; Ting Song Lim; Jeng Feng Chen; Wilson Ho; Joyce Lim; Lanny Juniarty; Yong Seng Kee; Seong Jae Youn; Sabrina Fabi
Journal:  J Clin Aesthet Dermatol       Date:  2021-05-01

Review 4.  Noninvasive skin tightening: focus on new ultrasound techniques.

Authors:  Sabrina Guillen Fabi
Journal:  Clin Cosmet Investig Dermatol       Date:  2015-02-05

5.  Eye damage due to cosmetic ultrasound treatment: a case report.

Authors:  Yuanyuan Chen; Zhongyu Shi; Yin Shen
Journal:  BMC Ophthalmol       Date:  2018-08-29       Impact factor: 2.209

6.  Acute cataract by a high-intensity focused ultrasound procedure: a case report.

Authors:  Toru Ikoma; Teppei Shibata; Naoko Shibata; Tsuyoshi Mito; Eri Kubo; Hiroshi Sasaki
Journal:  BMC Ophthalmol       Date:  2022-04-09       Impact factor: 2.209

7.  Quantified Facial Rejuvenation Utilizing High Intense Focus Ultrasound with Multiple Penetrative Depths.

Authors:  Man-Lok Lio; Chang-Cheng Chang; Andy Deng-Chi Chuang; Li-Cheng Tsai; Chien-Chou Chen
Journal:  Clin Cosmet Investig Dermatol       Date:  2022-03-19

8.  Single Treatment, Single Depth Superficial Microfocused Ultrasound with Visualization for Rhytid Improvement.

Authors:  Stephen Lowe
Journal:  Plast Reconstr Surg Glob Open       Date:  2021-07-13

9.  Development and Validation of a Photonumeric Scale for Evaluation of Infraorbital Hollows.

Authors:  Lisa Donofrio; Jean Carruthers; Bhushan Hardas; Diane K Murphy; Derek Jones; Jonathan M Sykes; Alastair Carruthers; Lela Creutz; Ann Marx; Sara Dill
Journal:  Dermatol Surg       Date:  2016-10       Impact factor: 3.398

  9 in total