Literature DB >> 25098847

A retrospective comparison of the modified tension band technique and the parallel titanium cannulated lag screw technique in transverse patella fracture.

Cheng-Xue Wang1, Lei Tan, Bao-Chang Qi, Xiang-Feng Hou, Yu-Long Huang, Hai-Peng Zhang, Tie-Cheng Yu.   

Abstract

OBJECTIVE: To compare efficacy between the modified tension band technique and the parallel titanium cannulated lag screw technique for the transverse patella fracture.
METHODS: Seventy-two patients were retrospectively analyzed aged 22 to 79 years (mean, 55.6 years) with transverse patella fractures, among whom 37 patients underwent the modified tension band and 35 patients received the titanium cannulated lag screw. Patients were followed up for 1-3 years. We analyzed the difference of operation time, complications, fracture reduction, fracture healing time, and the Iowa score for knee function between both groups.
RESULTS: In modified tension band group, five patients had skin irritation and seven suffered wire migration, two of whom required a second operation. In comparison, there were no complications in the titanium cannulated lag screw group, which also had a higher fracture reduction rate and less operation time.
CONCLUSION: The parallel titanium cannulated lag screw technique has superior results and should be considered as an alternative method to treat transverse patella fracture.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25098847

Source DB:  PubMed          Journal:  Chin J Traumatol        ISSN: 1008-1275


  8 in total

1.  Clinical Outcomes of Cannulated Screws versus Ring Pin versus K-Wire with Tension Band Fixation Techniques in the Treatment of Transverse Patellar Fractures: A Case-Control Study with Minimum 2-Year Follow-Up.

Authors:  Junchuan Liu; Yiming Ge; Guolei Zhang; Xuehong Zheng; Liang Gao; Enzeng Xing; Jiangfeng Lu; Jun Di; Junfei Guo
Journal:  Biomed Res Int       Date:  2022-06-15       Impact factor: 3.246

2.  Comparison of Functional and Radiological Outcomes of Transverse Patellar Fractures Fixed with Tension Band Fixation Using Cannulated Screws and Kirschner Wires: A Prospective Randomized Study.

Authors:  Nikhil Drolia; Siddhartha Sinha; Shiva Raj Paneru; Arvind Kumar; Javed Jameel; Sandeep Kumar; Bikram Shrestha; Guru P Khanal
Journal:  Indian J Orthop       Date:  2021-08-30       Impact factor: 1.033

3.  Treatment of displaced transverse fractures of the patella: modified tension band wiring technique with or without augmented circumferential cerclage wire fixation.

Authors:  Tien-Yu Yang; Tsan-Wen Huang; Po-Yao Chuang; Kuo-Chin Huang
Journal:  BMC Musculoskelet Disord       Date:  2018-05-24       Impact factor: 2.362

4.  Role of an additional third screw in the fixation of transverse patellar fracture with two parallel cannulated screw and anterior wire.

Authors:  Chih-Wei Chang; Chih-Hsien Chen; Chun-Ting Li; Yen-Nien Chen; Tai-Hua Yang; Chia-Jung Chang; Chih-Han Chang
Journal:  BMC Musculoskelet Disord       Date:  2020-11-14       Impact factor: 2.362

5.  Comparison of the Therapeutic Effects of Tension Band with Cannulated Screw and Tension Band with Kirschner Wire on Patella Fracture.

Authors:  Chengwu Liu; Haitao Ren; Chunyan Wan; Jianlin Ma
Journal:  Comput Math Methods Med       Date:  2020-08-25       Impact factor: 2.238

6.  A retrospective cohort study on prevalence of postoperative complications in comminuted patellar fractures: comparisons among stabilized with Cannulated-Screw, Kirschner-Wire, or Ring-Pin Tension Bands.

Authors:  Xiao-Zhong Zhu; Teng-Li Huang; Hong-Yi Zhu; Bing-Bo Bao; Tao Gao; Xing-Wei Li; Jun-Qing Lin; Xian-You Zheng
Journal:  BMC Musculoskelet Disord       Date:  2021-01-11       Impact factor: 2.362

7.  The clinical outcomes and complications of combined fixation with cannulated screws and the modified Pyrford technique for the treatment of transverse patellar fractures: a case series study.

Authors:  Yihan Li; Qingxian Tian; Kunpeng Leng; Meng Guo
Journal:  BMC Surg       Date:  2022-09-10       Impact factor: 2.030

8.  Efficacy of K-wire tension band fixation compared with other alternatives for patella fractures: a meta-analysis.

Authors:  Yinwang Zhang; Zhen Xu; Wuxue Zhong; Fuhai Liu; Jie Tang
Journal:  J Orthop Surg Res       Date:  2018-09-05       Impact factor: 2.359

  8 in total