Literature DB >> 25098350

Comparing quantitative and qualitative indices of the donated corneas maintained in Optisol-GS with those kept in Eusol-C.

Mozhgan Rezaei Kanavi1, Mohammad Ali Javadi, Tahereh Chamani, Pejman Fahim, Fatemeh Javadi.   

Abstract

This study was conducted to compare the quantitative and qualitative indices of the donated corneas maintained in either Optisol-GS or Eusol-C storage media. In an ante-grade single blind study, two corneas from each donor with a death to preservation time of less than 30 h and with a minimum of "an apparent good cornea rating" were maintained in corneal storage media; randomly one in Optisol-GS and the other in Eusol-C. Slit-lamp biomicroscopic and specular microscopic examinations were performed on days 1 and 7. The results of the qualitative and quantitative indices and the final cornea rating were recorded. Statistical analyses were performed to evaluate any differences between the two media. 180 corneas from 90 donors with an age range of 29.3 ± 22.4 years were allocated in two groups: 90 corneas in Optisol-GS and the other 90 in Eusol-C. Five corneas in Optisol-GS and four corneas in Eusol-C were excluded from the study due to lack of specular images. There was no significant change of endothelial rating from day 1 to day 7 between two media (P = 0.175). As the maintenance time of the donated corneas increased, no significant difference was noted between the two groups in terms of endothelial indices, stromal edema, and Descemet's folding. This study shows no superiority between Eusol-C and Optisol-GS in short term preservation of donated corneas.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25098350     DOI: 10.1007/s10561-014-9466-5

Source DB:  PubMed          Journal:  Cell Tissue Bank        ISSN: 1389-9333            Impact factor:   1.522


  4 in total

1.  Factors influencing endothelial cell density of corneas for transplantation.

Authors:  Thatiane Lima Sampaio; Isabela Pereira Rodrigues; Micheline Borges Lucas Cresta; Anna Cláudia de Oliveira Queiroz; Thayssa Neiva da Fonseca Victer; Daniela Ferreira Salomão Pontes; Wildo Navegantes de Araújo; Sônia Nair Báo; Maria Regina Catai Chalita
Journal:  Cell Tissue Bank       Date:  2020-11-09       Impact factor: 1.522

2.  Swept-source OCT for corneal graft quantitative evaluation in the eye bank and the correlation of the measurements to pre-excision values.

Authors:  Bartlomiej J Kaluzny; Patryk Mlyniuk; Slawomir Liberski; Alfonso Jimenez-Villar; Anna Machalińska; Ireneusz Grulkowski
Journal:  Sci Rep       Date:  2022-09-01       Impact factor: 4.996

3.  Comparisons of Cornea Cold, a New Corneal Storage Medium, and Optisol-GS.

Authors:  Joanne W Ho; Hoon Jung; Mimi Chau; James A Kuchenbecker; Michael Banitt
Journal:  Cornea       Date:  2020-08       Impact factor: 3.152

4.  Comparison of structural integrity and functional status of corneal endothelium stored in Cornisol and Optisol-GS.

Authors:  Yogapriya Sundaresan; Ganesh Govardhan Gaikwad; Kishan Anilkumar Prajapati; N Venkatesh Prajna; Gowri Priya Chidambaranathan
Journal:  Indian J Ophthalmol       Date:  2019-10       Impact factor: 1.848

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.