Literature DB >> 25098319

Evaluation of bias voltage modulation sequence for nonlinear contrast agent imaging using a capacitive micromachined ultrasonic transducer array.

Anthony Novell1, Mathieu Legros, Jean-Marc Grégoire, Paul A Dayton, Ayache Bouakaz.   

Abstract

Many clinical diagnoses have now been improved thanks to the development of new techniques dedicated to contrast agent nonlinear imaging. Over the past few years, Capacitive Micromachined Ultrasonic Transducers (cMUTs) have emerged as a promising alternative to traditional piezoelectric transducers. One notable advantage of cMUTs is their wide frequency bandwidth. However, their use in nonlinear imaging approaches such as those used to detect contrast agents have been challenging due their intrinsic nonlinear character. We propose a new contrast imaging sequence, called bias voltage modulation (BVM), specifically developed for cMUTs to suppress their inherent nonlinear behavior. Theoretical and experimental results show that a complete cancellation of the nonlinear signal from the source can be reached when the BVM sequence is implemented. In-vitro validation of the sequence is performed using a cMUT probe connected to an open scanner and a flow phantom setup containing SonoVue microbubbles. Compared to the standard amplitude modulation imaging mode, a 6 dB increase of contrast-to-tissue ratio was achieved when the BVM sequence is applied. These results reveal that the problem of cMUT nonlinearity can be addressed, thus expanding the potential of this new transducer technology for nonlinear contrast agent detection and imaging.

Mesh:

Substances:

Year:  2014        PMID: 25098319     DOI: 10.1088/0031-9155/59/17/4879

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  5 in total

1.  Phase and Amplitude Modulation Methods for Nonlinear Ultrasound Imaging With CMUTs.

Authors:  Sarp Satir; F Levent Degertekin
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2016-04-21       Impact factor: 2.725

2.  Wideband acoustic activation and detection of droplet vaporization events using a capacitive micromachined ultrasonic transducer.

Authors:  Anthony Novell; Christopher B Arena; Omer Oralkan; Paul A Dayton
Journal:  J Acoust Soc Am       Date:  2016-06       Impact factor: 1.840

3.  Dual-Frequency Piezoelectric Endoscopic Transducer for Imaging Vascular Invasion in Pancreatic Cancer.

Authors:  Brooks D Lindsey; Jinwook Kim; Paul A Dayton; Xiaoning Jiang
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2017-05-08       Impact factor: 2.725

4.  Optimization of multi-pulse sequences for nonlinear contrast agent imaging using a cMUT array.

Authors:  Anthony Novell; Christopher B Arena; Sandeep Kasoji; Paul A Dayton
Journal:  Phys Med Biol       Date:  2015-03-24       Impact factor: 3.609

5.  Dual-frequency piezoelectric transducers for contrast enhanced ultrasound imaging.

Authors:  K Heath Martin; Brooks D Lindsey; Jianguo Ma; Mike Lee; Sibo Li; F Stuart Foster; Xiaoning Jiang; Paul A Dayton
Journal:  Sensors (Basel)       Date:  2014-11-04       Impact factor: 3.576

  5 in total