| Literature DB >> 25092413 |
Tsutomu Shimada1, Joan Kelly2, William A LaMarr2, Naomi van Vlies3, Eriko Yasuda1, Robert W Mason1, William Mackenzie1, Francyne Kubaski1, Roberto Giugliani4, Yasutsugu Chinen5, Seiji Yamaguchi6, Yasuyuki Suzuki7, Kenji E Orii8, Toshiyuki Fukao8, Tadao Orii8, Shunji Tomatsu9.
Abstract
Mucopolysaccharidoses (MPS) are caused by deficiency of one of a group of specific lysosomal enzymes, resulting in excessive accumulation of glycosaminoglycans (GAGs). We previously developed GAG assay methods using liquid chromatography tandem mass spectrometry (LC-MS/MS); however, it takes 4-5 min per sample for analysis. For the large numbers of samples in a screening program, a more rapid process is desirable. The automated high-throughput mass spectrometry (HT-MS/MS) system (RapidFire) integrates a solid phase extraction robot to concentrate and desalt samples prior to direction into the MS/MS without chromatographic separation; thereby allowing each sample to be processed within 10s (enabling screening of more than one million samples per year). The aim of this study was to develop a higher throughput system to assay heparan sulfate (HS) using HT-MS/MS, and to compare its reproducibility, sensitivity and specificity with conventional LC-MS/MS. HS levels were measured in the blood (plasma and serum) from control subjects and patients with MPS II, III, or IV and in dried blood spots (DBS) from newborn controls and patients with MPS I, II, or III. Results obtained from HT-MS/MS showed 1) that there was a strong correlation of levels of disaccharides derived from HS in the blood, between those calculated using conventional LC-MS/MS and HT-MS/MS, 2) that levels of HS in the blood were significantly elevated in patients with MPS II and III, but not in MPS IVA, 3) that the level of HS in patients with a severe form of MPS II was higher than that in an attenuated form, 4) that reduction of blood HS level was observed in MPS II patients treated with enzyme replacement therapy or hematopoietic stem cell transplantation, and 5) that levels of HS in newborn DBS were elevated in patients with MPS I, II or III, compared to those of control newborns. In conclusion, HT-MS/MS provides much higher throughput than LC-MS/MS-based methods with similar sensitivity and specificity in an HS assay, indicating that HT-MS/MS may be feasible for diagnosis, monitoring, and newborn screening of MPS.Entities:
Keywords: Automated high-throughput mass spectrometry; Biomarker; Heparan sulfate; Mucopolysaccharidoses; Newborn screening
Mesh:
Substances:
Year: 2014 PMID: 25092413 PMCID: PMC4177953 DOI: 10.1016/j.ymgme.2014.07.008
Source DB: PubMed Journal: Mol Genet Metab ISSN: 1096-7192 Impact factor: 4.797