Literature DB >> 25092137

Voltammetric determination of platinum at a lead film electrode in environmental water samples.

Katarzyna Tyszczuk-Rotko1, Marek Rotko.   

Abstract

The paper presents the first report on the application of a lead film electrode for the determination of ultratrace concentrations of platinum. The procedure is based on preconcentration of the Pt(IV)-formaldehyde complexes at an in situ plated lead film electrode held at -0.9 V (vs. Ag/AgCl), followed by a negatively sweeping differential pulse voltammetric scan. The composition of the supporting electrolyte, the influence of accumulation potential and time on the sensitivity of platinum responses are discussed. The detection limit of Pt(IV) with the accumulation time of 60 was equal to 9.2 × 10(-12) mol L(-1). The application of this method was tested by recovery of Pt(IV) from spiked environmental water samples.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25092137     DOI: 10.1007/s10661-014-3968-2

Source DB:  PubMed          Journal:  Environ Monit Assess        ISSN: 0167-6369            Impact factor:   2.513


  6 in total

Review 1.  Monitoring of platinum in the environment.

Authors:  K Pyrzyńska
Journal:  J Environ Monit       Date:  2000-12

2.  Voltammetric determination of platinum in inorganic complexes and in water, geological and biological matrices using laboratory- and field-based instrumentation.

Authors:  S B Adeloju; A M Bond; S N Tan; G Wei
Journal:  Analyst       Date:  1990-12       Impact factor: 4.616

3.  Determination of uranium by adsorptive stripping voltammetry at a lead film electrode.

Authors:  Mieczyslaw Korolczuk; Katarzyna Tyszczuk; Malgorzata Grabarczyk
Journal:  Talanta       Date:  2006-12-23       Impact factor: 6.057

4.  Adsorptive stripping voltammetric determination of trace concentrations of molybdenum at an in situ plated lead film electrode.

Authors:  Katarzyna Tyszczuk; Mieczyslaw Korolczuk
Journal:  Anal Chim Acta       Date:  2008-07-04       Impact factor: 6.558

5.  Stripping voltammetric determination of platinum metals at a carbon paste electrode modified with cationic surfactants.

Authors:  Ivan Svancara; Michal Galík; Karel Vytras
Journal:  Talanta       Date:  2006-12-13       Impact factor: 6.057

6.  Trace determination of platinum-II. Analysis in ores by pulse polarography after fire-assay collection.

Authors:  P W Alexander; R Hoh; L E Smythe
Journal:  Talanta       Date:  1977-09       Impact factor: 6.057

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.