Literature DB >> 25090802

Medium-term outcome of titanium nitride, mobile bearing total knee replacement.

Aso Mohammed, Andy Metcalfe, David Woodnutt.   

Abstract

This retrospective study examined the medium term outcome of 305 Titanium Nitride (TiN) Mobile bearing total knee. At ten years after the start of the study, there was a significant improvement (p < 0.0001) in the post-operative knee scores. The ten year survival with revision for any reason as the end point was 95.1% (95% CI 92.4 to 97.8). The ten year survival rate with revision for aseptic loosening as the end point was 99.1% (95% CI 97.8 to 100%). A total of 15 knees (4.9%, overall) required revision. No cases were revised due to sepsis. Based on these results, the surface Titanium Nitride ceramic, mobile-bearing total knee replacement has proved to be a reliable implant at 10 years when used in primary knee replacement.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25090802

Source DB:  PubMed          Journal:  Acta Orthop Belg        ISSN: 0001-6462            Impact factor:   0.500


  5 in total

1.  No clinical difference between TiN-coated versus uncoated cementless CoCrMo mobile-bearing total knee arthroplasty; 10-year follow-up of a randomized controlled trial.

Authors:  Jan K G Louwerens; Niels Hockers; Gijs Achten; Inger N Sierevelt; Peter A Nolte; Ruud P van Hove
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2020-05-04       Impact factor: 4.342

2.  Evaluation of 1031 primary titanium nitride coated mobile bearing total knee arthroplasties in an orthopedic clinic.

Authors:  Stefan J M Breugem; Jeroen Linnartz; Inger Sierevelt; Jon D Bruijn; Marcel J M Driessen
Journal:  World J Orthop       Date:  2017-12-18

3.  The Effect of N, C, Cr, and Nb Content on Silicon Nitride Coatings for Joint Applications.

Authors:  Luimar Correa Filho; Susann Schmidt; Cecilia Goyenola; Charlotte Skjöldebrand; Håkan Engqvist; Hans Högberg; Markus Tobler; Cecilia Persson
Journal:  Materials (Basel)       Date:  2020-04-17       Impact factor: 3.623

4.  High wear resistance of femoral components coated with titanium nitride: a retrieval analysis.

Authors:  Christian Fabry; Carmen Zietz; Axel Baumann; Reinhard Ehall; Rainer Bader
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-05-20       Impact factor: 4.342

Review 5.  Titanium-Nitride Coating of Orthopaedic Implants: A Review of the Literature.

Authors:  Ruud P van Hove; Inger N Sierevelt; Barend J van Royen; Peter A Nolte
Journal:  Biomed Res Int       Date:  2015-10-25       Impact factor: 3.411

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.