In-line pressure within a HOTLINE® Fluid Warmer, under various flow conditions.

Midoriko Higashi1, Ken Yamaura, Yukie Matsubara, Takuya Fukudome, Sumio Hoka.   

Abstract

Roller pump infusion devices are widely used for rapid infusion, and may be combined with separate warming devices. There may be instances however, where the pressures generated by the roller pump may not be compatible with the warming device. We assessed a commonly used roller pump in combination with a HOTLINE® Fluid Warmer, and found that it could generate pressures exceeding the HOTLINE® manufacturers specifications. This was of concern because the HOTLINE® manufacturer guideline states that not for use with pressure devices generating over 300 mmHg. Pressure greater than 300 mmHg may compromise the integrity of the HOTLINE® Fluid Warming Set. The aim of this study was to compare in-line pressure within a HOTLINE® Fluid Warmer at different infusion rates of a roller pump using various sizes of intravenous cannulae. The rapid infusion system comprised a 500 mL-normal saline bag, roller pump type infusion device, HOTLINE® Fluid Warmer (blood and fluid warmer system), and six different sizes of intravenous cannulae. In-line pressure was measured proximal to the HOTLINE® (pre-warmer) and proximal to the cannula (post-warmer), at flow rate of 50-160 mL/min. The in-line pressures increased significantly with increasing flow rate. The pre-warmer pressures exceeded 300 mmHg when the flow rate was ≥120 mL/min with 20-gauge, 48 mm length cannula, 130 with 20-gauge, 25 mm cannula, and 160 mL/min with 18-gauge, 48 mm cannula. However, they were <300 mmHg at any flow rates with 18-gauge, 30 mm cannula and 16-gauge cannulae. The post-warmer pressures exceeded 300 mmHg at the flow rate of 140 mL/min with 20-gauge, 48 mm cannula, and 160 mL/min with 20-gauge, 25 mm cannula, while they were <300 mmHg at any flow rates with 18 and 16-gauge cannulae. The in-line pressure within a HOTLINE® could exceed 300 mmHg, depending on the flow rate and size and length of cannula. It is important to pay attention to the size and length of cannulae and flow rate to keep the maximum in-line pressure<300 mmHg when a roller pump type infusion device is used.

Entities:  

Mesh:

Year:  2014        PMID: 25087123     DOI: 10.1007/s10877-014-9605-3

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  9 in total

1.  Can anaesthetic management influence surgical-wound healing?

Authors:  D Buggy
Journal:  Lancet       Date:  2000-07-29       Impact factor: 79.321

2.  Flow rates and warming efficacy with Hotline and Ranger blood/fluid warmers.

Authors:  Peter E Horowitz; Miguel A Delagarza; Jaime J Pulaski; Robert A Smith
Journal:  Anesth Analg       Date:  2004-09       Impact factor: 5.108

3.  The properties of an improvised piston pump for the rapid delivery of intravenous fluids.

Authors:  C M Smart; C W Primrose; A L Peters; E J Speirits
Journal:  Anaesthesia       Date:  2014-01-03       Impact factor: 6.955

4.  Simulated clinical evaluation of conventional and newer fluid-warming devices.

Authors:  N Patel; D M Knapke; C E Smith; T E Napora; A C Pinchak; J F Hagen
Journal:  Anesth Analg       Date:  1996-03       Impact factor: 5.108

5.  Effects of rapid infusion with high pressure and large-bore i.v. tubing on red blood cell lysis and warming.

Authors:  J R Mateer; B W Perry; B M Thompson; J F Tucker; C Aprahamian
Journal:  Ann Emerg Med       Date:  1985-10       Impact factor: 5.721

6.  Perioperative maintenance of normothermia reduces the incidence of morbid cardiac events. A randomized clinical trial.

Authors:  S M Frank; L A Fleisher; M J Breslow; M S Higgins; K F Olson; S Kelly; C Beattie
Journal:  JAMA       Date:  1997-04-09       Impact factor: 56.272

7.  Mild hypothermia increases blood loss and transfusion requirements during total hip arthroplasty.

Authors:  H Schmied; A Kurz; D I Sessler; S Kozek; A Reiter
Journal:  Lancet       Date:  1996-02-03       Impact factor: 79.321

8.  Perioperative normothermia to reduce the incidence of surgical-wound infection and shorten hospitalization. Study of Wound Infection and Temperature Group.

Authors:  A Kurz; D I Sessler; R Lenhardt
Journal:  N Engl J Med       Date:  1996-05-09       Impact factor: 91.245

9.  The effect of manual bulb pump infusion systems on venous luminal pressure and vein wall integrity.

Authors:  D B Goodie
Journal:  Anesth Analg       Date:  1995-03       Impact factor: 5.108

  9 in total
  1 in total

1.  A pressure-resistant peripherally inserted central catheter is as useful as a central venous catheter for rapid fluid infusion: an in vitro study.

Authors:  Jun Maki; Makoto Sumie; Tomoko Ide; Masako Nagamatsu; Katsuyuki Matsushita; Kazuhiro Shirozu; Midoriko Higashi; Ken Yamaura
Journal:  BMC Anesthesiol       Date:  2022-07-04       Impact factor: 2.376

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.