Literature DB >> 25086699

Real-time aortic valve segmentation from transesophageal echocardiography sequence.

Junfeng Cai1, Xiahai Zhuang, Yuanyuan Nie, Zhe Luo, Lixu Gu.   

Abstract

PURPOSE: Geometric features of the aortic valve play an important role in many applications, such as the clinical diagnostics, shape modeling and image-guided cardiac interventions, especially for the transcatheter aortic valve implantation (TAVI) procedure. However, few works have been reported on the topic of aortic valve segmentation from transesophageal echocardiography (TEE) sequences. To obtain accurate segmentation results and further provide valid support for TAVI, this paper presents a real-time method for segmenting the aortic valve from intraoperative, short-axis view TEE sequences, using an improved probability estimation and continuous max-flow (CMF) approach.
METHODS: The proposed segmentation method includes two key stages: (1) In the probability estimation stage, five different prior frames spanning a cardiac circle are firstly selected with the aortic valve manually segmented by an expert. Then, the improved composite probability estimation (CPE) and single probability estimation (SPE) over the five prior frames are, respectively, constructed based on their radial average intensity and radial distance. (2) In the energy function construction stage, the similarity metric is calculated to find out the matching exponents between the current input TEE frame and the prior frames. The typical foreground and background intensities of prior images are therefore used to construct the corresponding energy function. Finally, the CMF approach, accelerated with a graphic processing unit (GPU), is employed to achieve the aortic valve contours in real time.
RESULTS: The evaluation study contained 30 sequences, with each containing 62-146 short-axis TEE frames. The results were compared with the manual segmentation (ground truth). The average symmetric contour distance (ASCD), dice metric (DM) and the reliability of the algorithm reached 0.85 ± 0.21 mm, 0.96 ± 0.01 and 0.90 (d = 0.95), respectively, and the computation time was 57.04 ± 8.98 ms per frame.
CONCLUSION: The experiment results reveal that the proposed method can achieve accurate and real-time segmentation of aortic valve from TEE sequence of short-axis view.

Entities:  

Mesh:

Year:  2014        PMID: 25086699     DOI: 10.1007/s11548-014-1104-y

Source DB:  PubMed          Journal:  Int J Comput Assist Radiol Surg        ISSN: 1861-6410            Impact factor:   2.924


  14 in total

1.  Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery.

Authors:  Martin B Leon; Craig R Smith; Michael Mack; D Craig Miller; Jeffrey W Moses; Lars G Svensson; E Murat Tuzcu; John G Webb; Gregory P Fontana; Raj R Makkar; David L Brown; Peter C Block; Robert A Guyton; Augusto D Pichard; Joseph E Bavaria; Howard C Herrmann; Pamela S Douglas; John L Petersen; Jodi J Akin; William N Anderson; Duolao Wang; Stuart Pocock
Journal:  N Engl J Med       Date:  2010-09-22       Impact factor: 91.245

2.  An experimental comparison of min-cut/max-flow algorithms for energy minimization in vision.

Authors:  Yuri Boykov; Vladimir Kolmogorov
Journal:  IEEE Trans Pattern Anal Mach Intell       Date:  2004-09       Impact factor: 6.226

Review 3.  Ultrasound image segmentation: a survey.

Authors:  J Alison Noble; Djamal Boukerroui
Journal:  IEEE Trans Med Imaging       Date:  2006-08       Impact factor: 10.048

4.  A fuzzy locally adaptive Bayesian segmentation approach for volume determination in PET.

Authors:  Mathieu Hatt; Catherine Cheze le Rest; Alexandre Turzo; Christian Roux; Dimitris Visvikis
Journal:  IEEE Trans Med Imaging       Date:  2009-01-13       Impact factor: 10.048

5.  Intra-operative 2-D ultrasound and dynamic 3-D aortic model registration for magnetic navigation of transcatheter aortic valve implantation.

Authors:  Zhe Luo; Junfeng Cai; Terry M Peters; Lixu Gu
Journal:  IEEE Trans Med Imaging       Date:  2013-07-30       Impact factor: 10.048

6.  A novel aortic valve segmentation from ultrasound image using continuous max-flow approach.

Authors:  Yuanyuan Nie; Zhe Luo; Junfeng Cai; Lixu Gu
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2013

7.  Max-flow segmentation of the left ventricle by recovering subject-specific distributions via a bound of the Bhattacharyya measure.

Authors:  Ismail Ben Ayed; Hua-Mei Chen; Kumaradevan Punithakumar; Ian Ross; Shuo Li
Journal:  Med Image Anal       Date:  2011-05-26       Impact factor: 8.545

8.  A pilot study on magnetic navigation for transcatheter aortic valve implantation using dynamic aortic model and US image guidance.

Authors:  Zhe Luo; Junfeng Cai; Lixu Gu
Journal:  Int J Comput Assist Radiol Surg       Date:  2013-01-11       Impact factor: 2.924

9.  Comparison and evaluation of methods for liver segmentation from CT datasets.

Authors:  Tobias Heimann; Bram van Ginneken; Martin A Styner; Yulia Arzhaeva; Volker Aurich; Christian Bauer; Andreas Beck; Christoph Becker; Reinhard Beichel; György Bekes; Fernando Bello; Gerd Binnig; Horst Bischof; Alexander Bornik; Peter M M Cashman; Ying Chi; Andrés Cordova; Benoit M Dawant; Márta Fidrich; Jacob D Furst; Daisuke Furukawa; Lars Grenacher; Joachim Hornegger; Dagmar Kainmüller; Richard I Kitney; Hidefumi Kobatake; Hans Lamecker; Thomas Lange; Jeongjin Lee; Brian Lennon; Rui Li; Senhu Li; Hans-Peter Meinzer; Gábor Nemeth; Daniela S Raicu; Anne-Mareike Rau; Eva M van Rikxoort; Mikaël Rousson; László Rusko; Kinda A Saddi; Günter Schmidt; Dieter Seghers; Akinobu Shimizu; Pieter Slagmolen; Erich Sorantin; Grzegorz Soza; Ruchaneewan Susomboon; Jonathan M Waite; Andreas Wimmer; Ivo Wolf
Journal:  IEEE Trans Med Imaging       Date:  2009-02-10       Impact factor: 10.048

10.  ROPES: a semiautomated segmentation method for accelerated analysis of three-dimensional echocardiographic data.

Authors:  Ivo Wolf; Mark Hastenteufel; Raffaele De Simone; Marcus Vetter; Gerald Glombitza; Sibylle Mottl-Link; Christian F Vahl; Hans-Peter Meinzer
Journal:  IEEE Trans Med Imaging       Date:  2002-09       Impact factor: 10.048