Literature DB >> 25086283

Clinical evaluation of a novel chemiluminescent immunoassay for the detection of anti-citrullinated peptide antibodies.

Tyler Webb1, Gabriella Lakos1, Andreas Swart2, Irmgard Gürtler2, Ennio Giulio Favalli3, Tommaso Schioppo3, Michael Mahler4.   

Abstract

BACKGROUND: We evaluated the analytical and clinical performances of a novel, automated chemiluminescent immunoassay in comparison with several anti-citrullinated protein antibody (ACPA) assays (2nd and 3rd generations) based on various platforms and technologies.
METHODS: Samples from rheumatoid arthritis (RA) patients (n=141) and controls (n=153) were collected based on an ordered ACPA test. All samples were tested with QUANTA Flash® CCP3, QUANTA Lite® CCP3, QUANTA Lite® CCP3.1, CCPlus and EliA® CCP assays. Rheumatoid factor (RF) was determined using Quantex RF(II). An additional cohort consisting of RA patients from three different sources (116, 79 and 50 samples), 61 juvenile idiopathic arthritis (JIA) patients and 233 controls were used in an extended evaluation on QUANTA Flash® CCP3 only. Precision and linearity of the QUANTA Flash® CCP3 were assessed according to CLSI guidelines.
RESULTS: All ACPA assays showed good qualitative and quantitative agreements. The Quanta Flash CCP3 assay showed good analytical and clinical performance. Based on the extended cohort, the sensitivity, specificity and likelihood ratios of the novel Quanta Flash® CCP3 were defined as 70.2%, 97.4% and 27.3/0.31, respectively.
CONCLUSION: Good agreements between different ACPA assays based on diverse platforms were found. Quanta Flash CCP3 is a reliable test for the fully automated and rapid detection of ACPA.
Copyright © 2014 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Autoantibodies; CCP; Citrullinated cyclic peptide; RA; Rheumatoid arthritis

Mesh:

Substances:

Year:  2014        PMID: 25086283     DOI: 10.1016/j.cca.2014.07.032

Source DB:  PubMed          Journal:  Clin Chim Acta        ISSN: 0009-8981            Impact factor:   3.786


  5 in total

Review 1.  Autoantibodies in Rheumatoid Arthritis - Laboratory and Clinical Perspectives.

Authors:  Johan Rönnelid; Carl Turesson; Alf Kastbom
Journal:  Front Immunol       Date:  2021-05-14       Impact factor: 7.561

2.  Comparison of Serological Biomarkers in Rheumatoid Arthritis and Their Combination to Improve Diagnostic Performance.

Authors:  Laura Martinez-Prat; Michael J Nissen; Céline Lamacchia; Chelsea Bentow; Laura Cesana; Pascale Roux-Lombard; Cem Gabay; Michael Mahler
Journal:  Front Immunol       Date:  2018-06-06       Impact factor: 7.561

3.  Low levels of anti-cyclic citrullinated peptide (CCP) 3.1 associated with diseases other than rheumatoid arthritis.

Authors:  James J Son; Mariko Ishimori; James Mirocha; Michael H Weisman; Lindsy J Forbess
Journal:  Medicine (Baltimore)       Date:  2021-04-23       Impact factor: 1.817

Review 4.  Detection of autoantibodies using chemiluminescence technologies.

Authors:  Michael Mahler; Chelsea Bentow; Josep Serra; Marvin J Fritzler
Journal:  Immunopharmacol Immunotoxicol       Date:  2015-11-02       Impact factor: 2.730

5.  Evaluation of the Clinical Performance of a Novel Chemiluminescent Immunoassay for Detection of Anticardiolipin and Anti-Beta2-Glycoprotein 1 Antibodies in the Diagnosis of Antiphospholipid Syndrome.

Authors:  Shulan Zhang; Ziyan Wu; Ping Li; Yina Bai; Fengchun Zhang; Yongzhe Li
Journal:  Medicine (Baltimore)       Date:  2015-11       Impact factor: 1.817

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.