Literature DB >> 25086124

Radiostereographic analysis of a shoulder surface replacement: does hydroxyapatite have a place?

D Nuttall1, A Birch1, J F Haines1, I A Trail1.   

Abstract

Resurfacing of the humeral head is commonly used within the UK to treat osteoarthritis (OA) of the shoulder. We present the results of a small prospective randomised study of this procedure using the Global CAP prosthesis with two different coatings, Porocoat and DuoFix hydroxyapatite (HA). We followed two groups of ten patients with OA of the shoulder for two years after insertion of the prosthesis with tantalum marker beads, recording pain, Constant-Murley and American Shoulder and Elbow Surgeons (ASES) outcome scores, and using radiostereometric analysis to assess migration. The outcomes were similar to those of other series, with significant reductions in pain (p = 0.003) and an improvement in the Constant (p = 0.001) and ASES scores (p = 0.006). The mean migration of the prosthesis three months post-operatively was 0.78 mm (0.51 to 1.69) and 0.72 mm (0.33 to 1.45) for the Porocoat and DuoFix groups, respectively. Analysis of variance indicated that the rate of migration reached a plateau after three months post-operatively in both groups. At follow-up of two years the mean migration was 1 mm (sd 1 (0.25 to 3.32)); in the Porocoat group and 0.8 mm (sd 0.4 (0.27 to 1.45)) in the DuoFix HA group. Significant migration of the prosthesis was seen in one patient who had received an anterior humeral bone graft. This prosthesis was later revised after 2.7 years. The addition of a coating of HA to the sintered surface does not improve fixation of this prosthesis. ©2013 The British Editorial Society of Bone & Joint Surgery.

Entities:  

Keywords:  Hydroxyapatite; Micromovement; Radiostereographic analysis; Shoulder; Shoulder surface replacement

Mesh:

Substances:

Year:  2014        PMID: 25086124     DOI: 10.1302/0301-620X.96B8.30534

Source DB:  PubMed          Journal:  Bone Joint J        ISSN: 2049-4394            Impact factor:   5.082


  3 in total

1.  Implant migration and functional outcome of Reverse Shoulder Lateralized Glenosphere Line Extension System: a study protocol for a randomized controlled trial.

Authors:  Marie Louise Jensen; Bo S Olsen; Marc R K Nyring; Müjgan Yilmaz; Michael M Petersen; Gunnar Flivik; Jeppe V Rasmussen
Journal:  Trials       Date:  2022-07-19       Impact factor: 2.728

Review 2.  The accuracy and precision of radiostereometric analysis in upper limb arthroplasty.

Authors:  Bart Ten Brinke; Annechien Beumer; Koen L M Koenraadt; Denise Eygendaal; Gerald A Kraan; Nina M C Mathijssen
Journal:  Acta Orthop       Date:  2017-03-02       Impact factor: 3.717

3.  Early migration of stemless and stemmed humeral components after total shoulder arthroplasty for osteoarthritis-study protocol for a randomized controlled trial.

Authors:  Marc Randall Kristensen Nyring; Bo S Olsen; Müjgan Yilmaz; Michael M Petersen; Gunnar Flivik; Jeppe V Rasmussen
Journal:  Trials       Date:  2020-10-07       Impact factor: 2.279

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.