Literature DB >> 25084245

Robotic mitral valve replacement for severe rheumatic mitral disease: perioperative technique, outcomes, and early results.

Sahin Senay1, Ahmet Umit Gullu, Muharrem Kocyigit, Aleks Degirmencioglu, Leyla Kilic, Hasan Karabulut, Cem Alhan.   

Abstract

OBJECTIVE: We report a case series of robotic mitral valve replacement in patients with severe rheumatic mitral disease.
METHODS: From March 2010 to June 2013, a total of 63 patients underwent robotic cardiac procedures. Robotic procedures were performed using the da Vinci Si surgical systems (Intuitive Surgical, Inc, Sunnyvale, CA USA). Eighteen of the patients (28.5%) underwent robotic mitral valve replacement. Rheumatic disease was the underlying pathology in all patients. The mean (SD) follow-up period was 18 (10) months.
RESULTS: The mean (SD) age and EuroSCORE of the patients were 51.2 (11) years and 4.1% (4%), respectively. Seven patients (38.8%) had an additional cardiac procedure. No operative and hospital mortality were observed. The mean (SD) cross-clamp time and cardiopulmonary bypass time were 116 (30) and 178 (54) minutes, the mean (SD) drainage was 430 (350) mL, the mean intubation time was 9.4 (7) hours, the rate of patients extubated within 6 hours or less was 94.4%, and the mean (SD) intensive care unit stay time was 30 (12) hours. Sixteen of the patients (88.8%) were discharged from the intensive care unit within the first 24 hours postoperatively. During the intensive care unit stay, one patient (5.5%) needed inotropic support. There was one early reoperation for bleeding (5.5%), one (5.5%) intensive care unit readmission, and one (5.5%) hospital readmission observed. During the midterm follow-up, there was no mortality and no need for reoperation or reintervention.
CONCLUSIONS: Robotic mitral valve replacement for severe rheumatic mitral disease is technically feasible. Early results are encouraging. Patient selection criteria for robotic mitral valve surgery may be expanded to include valve replacements.

Entities:  

Mesh:

Year:  2014        PMID: 25084245     DOI: 10.1097/IMI.0000000000000078

Source DB:  PubMed          Journal:  Innovations (Phila)        ISSN: 1556-9845


  3 in total

1.  [Comparison of quality of life and long-term outcomes following mitral valve replacement through robotically assisted versus median sternotomy approach].

Authors:  Haizhi Zhao; Huajun Zhang; Ming Yang; Cangsong Xiao; Yao Wang; Changqing Gao; Rong Wang
Journal:  Nan Fang Yi Ke Da Xue Xue Bao       Date:  2020-11-30

2.  Medical robots in cardiac surgery - application and perspectives.

Authors:  Karolina Kroczek; Piotr Kroczek; Zbigniew Nawrat
Journal:  Kardiochir Torakochirurgia Pol       Date:  2017-03-31

3.  Robotic mitral valve replacements with bioprosthetic valves in 52 patients: experience from a tertiary referral hospital.

Authors:  Chia-Cheng Kuo; Hsiao-Huang Chang; Chung-Hsi Hsing; Hiong-Ping Hii; Nan-Chun Wu; Chin-Ming Hsu; Chun-I Chen; Bor-Chih Cheng
Journal:  Eur J Cardiothorac Surg       Date:  2018-11-01       Impact factor: 4.191

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.