Literature DB >> 25083033

Evaluation and comparison of high-level microwave oven disinfection with chemical disinfection of dental gypsum casts.

K Meghashri1, Prasanna Kumar2, D Krishna Prasad3, Rakshit Hegde4.   

Abstract

BACKGROUND: The aim of this study was to evaluate and compare microwave disinfection with chemical disinfection of dental gypsum casts.
MATERIALS AND METHODS: A total of 120 casts were prepared from a silicone mold using Type III dental stone. Of the 120 casts, 60 casts were contaminated with 1 ml suspension of Staphylococcus aureus and 60 casts were contaminated with 1 ml suspension of Pseudomonas aeruginosa. Then, the casts were disinfected with microwave irradiation and chemical disinfection using the microwave oven and 0.5% sodium hypochlorite. Bacteriologic procedures were performed; the cfu/ml for each cast was calculated as a weighted mean. The results were analyzed using Kruskal-Wallis test and Mann-Whitney test.
RESULTS: The untreated casts showed Brain heart infusion broth counts of 106 log cfu/ml compared to irradiated and chemically disinfected casts, in which 105 log reduction of cfu/ml was seen. These results satisfied the requirements of current infection control guidelines for the dental laboratory. The results obtained for chemical disinfection were in equivalence with microwave disinfection.
CONCLUSIONS: Within the limitation of this in vitro study, it was found that microwave disinfection of casts for 5 min at 900 W gives high-level disinfection that complies with the current infection control guidelines for the dental laboratory and microwave disinfection method is an effective and validated method as chemical disinfection. How to cite the article: Meghashri K, Kumar P, Prasad DK, Hegde R. Evaluation and comparison of high-level microwave oven disinfection with chemical disinfection of dental gypsum casts. J Int Oral Health 2014;6(3):56-60 .

Entities:  

Keywords:  Chemical disinfection; dental gypsum cast; microwave disinfection

Year:  2014        PMID: 25083033      PMCID: PMC4109246     

Source DB:  PubMed          Journal:  J Int Oral Health        ISSN: 0976-1799


  15 in total

1.  A study on the effect of disinfectant chemicals on physical properties of die stone.

Authors:  A C Sarma; R Neiman
Journal:  Quintessence Int       Date:  1990-01       Impact factor: 1.677

2.  Microwave irradiation of contaminated dental casts.

Authors:  D R Davis; D A Curtis; J M White
Journal:  Quintessence Int       Date:  1989-08       Impact factor: 1.677

3.  High-level microwave disinfection of dental gypsum casts.

Authors:  Einar Berg; Oyunn Nielsen; Nils Skaug
Journal:  Int J Prosthodont       Date:  2005 Nov-Dec       Impact factor: 1.681

4.  Microwave disinfection of denture base materials colonized with Candida albicans.

Authors:  D L Dixon; L C Breeding; T A Faler
Journal:  J Prosthet Dent       Date:  1999-02       Impact factor: 3.426

5.  Immersion disinfection of irreversible hydrocolloid impressions in pH-adjusted sodium hypochlorite. Part 2: Effect on gypsum casts.

Authors:  M L Hutchings; K S Vandewalle; R S Schwartz; D G Charlton
Journal:  Int J Prosthodont       Date:  1996 May-Jun       Impact factor: 1.681

6.  Sterilizing dental instruments: evaluation of lubricating oils and microwave radiation.

Authors:  W R Hume; O F Makinson
Journal:  Oper Dent       Date:  1978       Impact factor: 2.440

7.  Effect of microwave oven drying on surface hardness of dental gypsum products.

Authors:  R J Luebke; K C Chan
Journal:  J Prosthet Dent       Date:  1985-09       Impact factor: 3.426

8.  Infection control in the dental office. Council on Dental Materials and Devices. Council on Dental Therapeutics.

Authors: 
Journal:  J Am Dent Assoc       Date:  1978-10       Impact factor: 3.634

9.  Gypsum casts as a potential source of microbial cross-contamination.

Authors:  R L Leung; S E Schonfeld
Journal:  J Prosthet Dent       Date:  1983-02       Impact factor: 3.426

10.  Avoiding cross-contamination in prosthodontics.

Authors:  M A Stern; R J Whitacre
Journal:  J Prosthet Dent       Date:  1981-08       Impact factor: 3.426

View more