Literature DB >> 25082138

Improving DNA data exchange: validation studies on a single 6 dye STR kit with 24 loci.

Pablo Martín1, Lourdes Fernández de Simón1, Gracia Luque1, María José Farfán1, Antonio Alonso2.   

Abstract

The idea of developing a new multiplex STR amplification system was conceived in 2011 as an effective way to implement the new European standard set (ESS) of 12 STR markers adopted by The Council of the European Union in 2009 while maintaining an effective compatibility and information exchange with the historical DNA profiles contained in the Spanish national DNA database (around 200,000 DNA profiles) mainly based on the 13 CODIS core STR loci plus D19S433 and D2S1338 markers. With this goal in mind we proposed to test and validate a single STR amplification system for simultaneous analysis of 21 STR markers covering both CODIS and ESS core STR loci plus three additional markers (D19S433, D2S1338, and SE33) also contained in commonly used STR kits and national DNA databases. In 2012, we started the first beta-testing with a 6-dye STR kit prototype containing 24 loci (now known as the GlobalFiler™ PCR Amplification Kit) developed by Life Technologies in response to the CODIS Core Loci Working Group's recommendation to expand the CODIS Core Loci. This prototype included our proposal of 21 autosomal STR markers and two Y-chromosome markers (DYS391 and Y-indel) and maximizes concordance with established databases and previously analyzed samples by maintaining primer sequences of previous Identifiler(®)/NGM SElect™ kits for the 21 STR markers except for TPOX. This paper describes the validation studies conducted with the first commercial available 6-dye STR kit for casework using a 3500 genetic analyzer for fragment detection that included the analysis of the following parameters and aspects: analytical threshold, sensitivity & stochastic threshold, heterozygous balance, stutter threshold, precision and accuracy, repeatability and reproducibility, genotype concordance, DNA mixtures, species specificity, and stability studies with case type samples. The studies demonstrated that the GlobalFiler™ system provided equivalent overall performance to previous forensic STR PCR kits, but with enhanced discrimination power for a better match efficiency that would reduce the chance of adventitious matches during DNA data exchange among national DNA databases.
Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Keywords:  6-Channel detection systems; Autosomal STR markers; DNA data exchange; Forensic validation studies; GlobalFiler™ system

Mesh:

Substances:

Year:  2014        PMID: 25082138     DOI: 10.1016/j.fsigen.2014.07.002

Source DB:  PubMed          Journal:  Forensic Sci Int Genet        ISSN: 1872-4973            Impact factor:   4.882


  6 in total

1.  Population genetic analysis of the GlobalFiler STR loci in 748 individuals from the Kazakh population of Xinjiang in northwest China.

Authors:  Honghua Zhang; Shuping Yang; Wei Guo; Bo Ren; Liwen Pu; Teng Ma; Mingying Xia; Li Jin; Liming Li; Shilin Li
Journal:  Int J Legal Med       Date:  2016-02-04       Impact factor: 2.686

Review 2.  The future of forensic DNA analysis.

Authors:  John M Butler
Journal:  Philos Trans R Soc Lond B Biol Sci       Date:  2015-08-05       Impact factor: 6.237

3.  Population data of 21 autosomal STR loci in Malaysian populations for human identification.

Authors:  Mohd Nor Azlan Rashid; Naji Arafat Mahat; Hussein Omar Khan; Roswanira Abdul Wahab; Hasmerya Maarof; Dzulkiflee Ismail; Aedrianee Reeza Alwi; SharifahNany RahayuKarmilla SyedHassan
Journal:  Int J Legal Med       Date:  2020-03-28       Impact factor: 2.686

4.  Efficacy of reduced-size short tandem repeat PCR analysis for degraded DNA samples.

Authors:  Jeongyong Kim; Hyojeong Kim; Youn-Hyoung Nam; Ja Hyun Lee; Hyo Sook Kim; Eungsoo Kim
Journal:  Genes Genomics       Date:  2021-04-19       Impact factor: 1.839

Review 5.  New Perspectives for Whole Genome Amplification in Forensic STR Analysis.

Authors:  Richard Jäger
Journal:  Int J Mol Sci       Date:  2022-06-25       Impact factor: 6.208

6.  Inter-laboratory study on standardized MPS libraries: evaluation of performance, concordance, and sensitivity using mixtures and degraded DNA.

Authors:  Petra Müller; Christian Sell; Thorsten Hadrys; Johannes Hedman; Steffi Bredemeyer; Francois-Xavier Laurent; Lutz Roewer; Sabrina Achtruth; Maja Sidstedt; Titia Sijen; Marc Trimborn; Natalie Weiler; Sascha Willuweit; Ingo Bastisch; Walther Parson
Journal:  Int J Legal Med       Date:  2019-11-19       Impact factor: 2.686

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.