Literature DB >> 25082137

mRNA heptaplex protocol for distinguishing between menstrual and peripheral blood.

Joanna Jakubowska1, Agnieszka Maciejewska2, Krzysztof P Bielawski3, Ryszard Pawłowski4.   

Abstract

The identification of menstrual blood is an important issue in forensic biology, but currently, there are no confirmatory methods for its detection. Here, we demonstrate a highly reliable simple heptaplex method that allows for the discrimination between menstrual and peripheral blood. The test has been used successfully in criminal casework, in which the origin of blood on a rape victim's underwear and trousers was questioned as being menstrual or traumatic peripheral blood. To solve this problem, transcripts of the following genes were used: mucin 4 (MUC4), human β-defensin 1 (HBD1), two matrix metalloproteinases (MMP7, MMP11), δ-aminolevulinate synthase 2 (ALAS2), hemoglobin alpha (HBA) and glucose 6-phosphate dehydrogenase (G6PDH). The sensitivity of the test is 0.3ng of RNA. The possibility of the detection and differentiation of menstrual and peripheral blood in mixtures that contain other body fluids was investigated. Reliable detection is possible for menstrual blood stains that are up to 1-2 years old if stored at room temperature. This easy approach, thanks to the amplification of 4 vaginal and 2 blood markers, minimizes the risk of false negative results.
Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Keywords:  Blood; Forensic genetics; Menstrual blood; Multiplex PCR; mRNA profiling

Mesh:

Substances:

Year:  2014        PMID: 25082137     DOI: 10.1016/j.fsigen.2014.07.006

Source DB:  PubMed          Journal:  Forensic Sci Int Genet        ISSN: 1872-4973            Impact factor:   4.882


  3 in total

1.  Sex-specific age association with primary DNA transfer.

Authors:  Panayiotis Manoli; Antonis Antoniou; Evy Bashiardes; Stavroulla Xenophontos; Marinos Photiades; Vaso Stribley; Michalis Mylona; Christiana Demetriou; Marios A Cariolou
Journal:  Int J Legal Med       Date:  2015-11-18       Impact factor: 2.686

2.  Discrimination of menstrual and peripheral blood traces using attenuated total reflection Fourier transform-infrared (ATR FT-IR) spectroscopy and chemometrics for forensic purposes.

Authors:  Ewelina Mistek-Morabito; Igor K Lednev
Journal:  Anal Bioanal Chem       Date:  2021-02-13       Impact factor: 4.142

3.  A stepwise strategy to distinguish menstrual blood from peripheral blood by Fisher's discriminant function.

Authors:  Hongxia He; Anquan Ji; Yixia Zhao; Na Han; Sheng Hu; Qinglan Kong; Li Jiang; Jian Ye; Yao Liu; Qifan Sun
Journal:  Int J Legal Med       Date:  2019-11-16       Impact factor: 2.686

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.