Literature DB >> 25081924

Objective volumetric comparison of room air versus carbon dioxide for colonic distention at screening CT colonography.

James L Patrick1, Joshua R Bakke, Peter Bannas, David H Kim, Meghan G Lubner, Perry J Pickhardt.   

Abstract

PURPOSE: To objectively compare colonic distention at CT colonography (CTC) achieved with manual room air vs. automated low-pressure carbon dioxide (CO2) using a novel automated volumetric quality assessment tool.
METHODS: Volumetric analysis was retrospectively performed on CTC studies in 300 asymptomatic adults using an automated quality assessment tool (V3D Colon [beta version], Viatronix). Colonic distention was achieved with room air self-administered to tolerance via hand-held pump (mean number of pumps, 39 ± 32) in 150 individuals (mean age, 59 years; 98 men, 51 women) and via continuous low-pressure automated infusion of CO2 in 150 individuals (mean age, 57 years; 89 men, 61 women). CTC studies in supine and prone position were assessed to determine total colonic volume (luminal gas and fluid). The colonic length along the automated centerline was also recorded to enable calculation of length-adjusted colonic volumes.
RESULTS: The mean total colonic volume (±SD) for individuals receiving room air and CO2 distention was 1809 ± 514 and 2223 ± 686 mL, respectively (p < 0.01). The prone position was better distended in 78.7% (118/150) of cases using room air; whereas, the supine was better in 66.0% (99/150) of CO2 cases (p < 0.01). Using a volume threshold of 2000 mL, 49 (32.7%) of room air cases and 92 (61.3%) of CO2 cases were above this cut-off. The mean length-adjusted colonic volume (mL/cm) for the room air and CO2 techniques was 9.9 ± 2.4 and 11.6 ± 2.6 mL/cm (p < 0.01).
CONCLUSIONS: Using automated volumetry allowed quantitative analyses of colonic volumes and objectively confirmed that continuous low-pressure CO2 provides greater overall colonic distention than the manual room air technique at CTC. The supine position demonstrated better distention with CO2, whereas the prone position was better distended with the room air technique.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25081924      PMCID: PMC4303556          DOI: 10.1007/s00261-014-0206-x

Source DB:  PubMed          Journal:  Abdom Imaging        ISSN: 0942-8925


  15 in total

1.  Quantification of distention in CT colonography: development and validation of three computer algorithms.

Authors:  Peter W Hung; David S Paik; Sandy Napel; Judy Yee; R Brooke Jeffrey; Andreas Steinauer-Gebauer; Juno Min; Ashwin Jathavedam; Christopher F Beaulieu
Journal:  Radiology       Date:  2002-02       Impact factor: 11.105

2.  Computed tomographic virtual colonoscopy to screen for colorectal neoplasia in asymptomatic adults.

Authors:  Perry J Pickhardt; J Richard Choi; Inku Hwang; James A Butler; Michael L Puckett; Hans A Hildebrandt; Roy K Wong; Pamela A Nugent; Pauline A Mysliwiec; William R Schindler
Journal:  N Engl J Med       Date:  2003-12-01       Impact factor: 91.245

3.  Performing an additional decubitus series at CT colonography.

Authors:  Christopher M Buchach; David H Kim; Perry J Pickhardt
Journal:  Abdom Imaging       Date:  2011-10

4.  Advice for optimizing colonic distention and minimizing risk of perforation during CT colonography.

Authors:  Abraham H Dachman
Journal:  Radiology       Date:  2006-05       Impact factor: 11.105

Review 5.  Incidence of colonic perforation at CT colonography: review of existing data and implications for screening of asymptomatic adults.

Authors:  Perry J Pickhardt
Journal:  Radiology       Date:  2006-05       Impact factor: 11.105

6.  Colorectal neoplasia: performance characteristics of CT colonography for detection in 300 patients.

Authors:  J Yee; G A Akerkar; R K Hung; A M Steinauer-Gebauer; S D Wall; K R McQuaid
Journal:  Radiology       Date:  2001-06       Impact factor: 11.105

7.  A comparison of virtual and conventional colonoscopy for the detection of colorectal polyps.

Authors:  H M Fenlon; D P Nunes; P C Schroy; M A Barish; P D Clarke; J T Ferrucci
Journal:  N Engl J Med       Date:  1999-11-11       Impact factor: 91.245

8.  NORCCAP (Norwegian colorectal cancer prevention): a randomised trial to assess the safety and efficacy of carbon dioxide versus air insufflation in colonoscopy.

Authors:  M Bretthauer; E Thiis-Evensen; G Huppertz-Hauss; L Gisselsson; T Grotmol; E Skovlund; G Hoff
Journal:  Gut       Date:  2002-05       Impact factor: 23.059

9.  Automated insufflation of carbon dioxide for MDCT colonography: distension and patient experience compared with manual insufflation.

Authors:  David Burling; Stuart A Taylor; Steve Halligan; Louise Gartner; Mehjabeen Paliwalla; Chandani Peiris; Leanne Singh; Paul Bassett; Clive Bartram
Journal:  AJR Am J Roentgenol       Date:  2006-01       Impact factor: 3.959

10.  Optimizing colonic distention for multi-detector row CT colonography: effect of hyoscine butylbromide and rectal balloon catheter.

Authors:  Stuart A Taylor; Steve Halligan; Vicky Goh; Simon Morley; Paul Bassett; Wendy Atkin; Clive I Bartram
Journal:  Radiology       Date:  2003-08-27       Impact factor: 11.105

View more
  4 in total

1.  Computed tomographic pneumocolonography in normal dogs.

Authors:  Michele A Steffey; Leticia Daniel; Sandra L Taylor; Rachel X Chen; Allison L Zwingenberger
Journal:  Vet Radiol Ultrasound       Date:  2014-12-28       Impact factor: 1.363

2.  CT colonography after incomplete optical colonoscopy: bowel preparation quality at same-day vs. deferred examination.

Authors:  Jake Theis; David H Kim; Meghan G Lubner; Alejandro Muñoz del Rio; Perry J Pickhardt
Journal:  Abdom Radiol (NY)       Date:  2016-01

Review 3.  Symptoms and diagnostic criteria of acquired Megacolon - a systematic literature review.

Authors:  Tahleesa Cuda; Ronny Gunnarsson; Alan de Costa
Journal:  BMC Gastroenterol       Date:  2018-01-31       Impact factor: 3.067

4.  Hemodynamic changes of abdominal organs after CT colonography with transrectal administration of CO2: evaluation with early-phase contrast-enhanced dynamic CT.

Authors:  Kenichiro Ihara; Hideko Onoda; Masahiro Tanabe; Akihiko Kanki; Katsuyoshi Ito
Journal:  Jpn J Radiol       Date:  2021-05-08       Impact factor: 2.374

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.