Literature DB >> 2508192

Radiation dose assessment in radioiodine therapy. 2. Practical implementation using quantitative scanning and PET, with initial results on thyroid carcinoma.

M A Flower1, T Schlesinger, P J Hinton, I Adam, A M Masoomi, M A Elbelli, R J Ott, V R McCready, C L Harmer.   

Abstract

We have designed special high-resolution, low-sensitivity collimators for a dual-headed whole-body scanner for imaging and quantifying therapy levels of iodine-131. In addition, we have used positron emission tomography (PET) with a low-cost large-area PET camera to achieve improved accuracy in the estimate to tumor mass. The physical performance of these two imaging systems is described. In order to illustrate the practical implementation of these systems for the assessment of radiation dose to normal and tumour tissue during radioiodine therapy, three clinical examples are reported, and a summary of the initial clinical results obtained from 16 patients with carcinoma of the thyroid is presented. The dose to normal thyroid remnants for patients undergoing ablation ranged from 16 to 400 Gy, while the dose to involved neck nodes ranged from 2.5 to 33 Gy for patients undergoing post-ablation radioiodine therapy. In one patient with distant metastasis in the spine, a dose of 100 Gy was achieved. The techniques described in this paper can be used to determine if sufficient activity can be accumulated in tumours to provide a therapeutic effect while minimising irradiation of normal tissues by avoiding administrations which do not provide tumouricidal radiation doses.

Entities:  

Mesh:

Substances:

Year:  1989        PMID: 2508192     DOI: 10.1016/0167-8140(89)90081-9

Source DB:  PubMed          Journal:  Radiother Oncol        ISSN: 0167-8140            Impact factor:   6.280


  8 in total

1.  Systemic radiotherapy.

Authors:  D Tait
Journal:  Eur J Nucl Med       Date:  1990

2.  Optimization and assessment of quantitative 124I imaging on a Philips Gemini dual GS PET/CT system.

Authors:  Rebecca A Gregory; Claire A Hooker; Mike Partridge; Glenn D Flux
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-03-14       Impact factor: 9.236

3.  Reply.

Authors:  O Sabri
Journal:  Eur J Nucl Med       Date:  2001-03

4.  Measuring the actual I-131 thyroid uptake curve with a collar detector system: a feasibility study.

Authors:  Peter Brinks; Koen Van Gils; Ellen Kranenborg; Jules Lavalaye; Dennis B M Dickerscheid; Jan B A Habraken
Journal:  Eur J Nucl Med Mol Imaging       Date:  2016-12-17       Impact factor: 9.236

Review 5.  Wire chambers revisited.

Authors:  R J Ott
Journal:  Eur J Nucl Med       Date:  1993-04

6.  Dosimetry of iodine 131 metaiodobenzylguanidine for treatment of resistant neuroblastoma: results of a UK study.

Authors:  S L Fielding; M A Flower; D Ackery; J T Kemshead; L S Lashford; I Lewis
Journal:  Eur J Nucl Med       Date:  1991

7.  A novel view on dosimetry-related radionuclide therapy: presentation of a calculatory model and its implementation for radioiodine therapy of metastasized differentiated thyroid carcinoma.

Authors:  Alexander R Stahl; Lutz Freudenberg; Andreas Bockisch; Walter Jentzen
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-02-27       Impact factor: 9.236

Review 8.  The applications of positron emission tomography to oncology.

Authors:  R J Ott
Journal:  Br J Cancer       Date:  1991-03       Impact factor: 7.640

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.