Literature DB >> 25081861

Removal of a Nexplanon implant located in the biceps muscle using a combination of ultrasound and fluoroscopy guidance.

Maryam Guiahi1, Kristina Tocce2, Stephanie Teal2, Tyler Green3, Paul Rochon3.   

Abstract

Despite modifications to avoid deep insertions, clinical experience with Nexplanon demonstrates that deep insertions still occur. We present a case of a Nexplanon found in the biceps muscle that was successfully removed with a small incision using a combination of ultrasound and fluoroscopy guidance by interventional radiologists.
Copyright © 2014 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Contraceptive implant; Deep insertion; Nexplanon; Removal

Mesh:

Substances:

Year:  2014        PMID: 25081861     DOI: 10.1016/j.contraception.2014.06.030

Source DB:  PubMed          Journal:  Contraception        ISSN: 0010-7824            Impact factor:   3.375


  5 in total

Review 1.  Contraceptive Implant Migration and Removal by Interventional Radiology.

Authors:  Salina Zhang; Pelin Batur; Charles Martin; Paul J Rochon
Journal:  Semin Intervent Radiol       Date:  2018-04-05       Impact factor: 1.513

2.  Referral Center Experience With Nonpalpable Contraceptive Implant Removals.

Authors:  Melissa C Matulich; Melissa J Chen; Natasha R Schimmoeller; Jennifer K Hsia; Suji Uhm; Machelle D Wilson; Mitchell D Creinin
Journal:  Obstet Gynecol       Date:  2019-10       Impact factor: 7.661

3.  Minimally invasive removal of deep contraceptive implants under continuous ultrasound guidance is effective, quick, and safe.

Authors:  Thibaut Jacques; Charlotte Brienne; Simon Henry; Hortense Baffet; Géraldine Giraudet; Xavier Demondion; Anne Cotten
Journal:  Eur Radiol       Date:  2021-10-14       Impact factor: 7.034

4.  Characteristics of Patients Requiring Surgical Removal of Subdermal Contraceptive Implants: A Case-Control Study.

Authors:  Leila Katabi; Erica Stevens; Mona Ascha; Kavita Arora
Journal:  Open Access J Contracept       Date:  2022-08-08

5.  Combined hysteroscopy-laparoscopy approach for excision of pelvic nitinol fragment from Essure contraceptive device: Role of intraoperative fluoroscopy for uterine conservation.

Authors:  E Scott Sills; Gianpiero D Palermo
Journal:  Obstet Gynecol Sci       Date:  2016-07-13
  5 in total