Literature DB >> 25078303

Inactivation of natural enteric bacteria in real municipal wastewater by solar photo-Fenton at neutral pH.

E Ortega-Gómez1, B Esteban García1, M M Ballesteros Martín2, P Fernández Ibáñez3, J A Sánchez Pérez4.   

Abstract

This study analyses the use of the solar photo-Fenton treatment in compound parabolic collector photo-reactors at neutral pH for the inactivation of wild enteric Escherichia coli and total coliform present in secondary effluents of a municipal wastewater treatment plant (SEWWTP). Control experiments were carried out to find out the individual effects of mechanical stress, pH, reactants concentration, and UVA radiation as well as the combined effects of UVA-Fe and UVA-H2O2. The synergistic germicidal effect of solar-UVA with 50 mg L(-1) of H2O2 led to complete disinfection (up to the detection limit) of total coliforms within 120 min. The disinfection process was accelerated by photo-Fenton, achieving total inactivation in 60 min reducing natural bicarbonate concentration found in the SEWWTP from 250 to 100 mg L(-1) did not give rise to a significant enhancement in bacterial inactivation. Additionally, the effect of hydrogen peroxide and iron dosage was evaluated. The best conditions were 50 mg L(-1) of H2O2 and 20 mg L(-1) of Fe(2+). Due to the variability of the SEWWTP during autumn and winter seasons, the inactivation kinetic constant varied between 0.07 ± 0.04 and 0.17 ± 0.04 min(-1). Moreover, the water treated by solar photo-Fenton fulfilled the microbiological quality requirement for wastewater reuse in irrigation as per the WHO guidelines and in particular for Spanish legislation.
Copyright © 2014 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Escherichia coli; Neutral pH; Photo-Fenton; Reclaimed water; Solar disinfection; Total coliform

Mesh:

Substances:

Year:  2014        PMID: 25078303     DOI: 10.1016/j.watres.2014.05.034

Source DB:  PubMed          Journal:  Water Res        ISSN: 0043-1354            Impact factor:   11.236


  2 in total

1.  Ecotoxicity evaluation of a WWTP effluent treated by solar photo-Fenton at neutral pH in a raceway pond reactor.

Authors:  A M Freitas; G Rivas; M C Campos-Mañas; J L Casas López; A Agüera; J A Sánchez Pérez
Journal:  Environ Sci Pollut Res Int       Date:  2016-06-22       Impact factor: 4.223

2.  Wastewater Treatment by Advanced Oxidation Process and Their Worldwide Research Trends.

Authors:  José Antonio Garrido-Cardenas; Belén Esteban-García; Ana Agüera; José Antonio Sánchez-Pérez; Francisco Manzano-Agugliaro
Journal:  Int J Environ Res Public Health       Date:  2019-12-25       Impact factor: 3.390

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.