Literature DB >> 25077704

High-throughput viscosity measurement using capillary electrophoresis instrumentation and its application to protein formulation.

Andrea Allmendinger1, Le-Ha Dieu2, Stefan Fischer3, Robert Mueller3, Hanns-Christian Mahler3, Jörg Huwyler4.   

Abstract

Viscosity characterization of protein formulations is of utmost importance for the development of subcutaneously administered formulations. However, viscosity determinations are time-consuming and require large sample volumes in the range of hundreds of microliters to a few milliliters, depending on the method used. In this article, an automated, high-throughput method is described to determine dynamic viscosity of Newtonian fluids using standard capillary electrophoresis (CE) equipment. CE is an analytical method routinely used for the separation and characterization of proteins. In our set-up, the capillary is filled with the test sample, and a constant pressure is applied. A small aliquot of riboflavin is subsequently loaded into the capillary and used as a dye to monitor movement of protein samples. Migration time of the riboflavin peak moving through the filled capillary is converted to the viscosity by applying the Hagen-Poiseuille's law. The instrument is operated without using an electrical field. Repeatability, robustness, linearity, and reproducibility were demonstrated for different capillary lots and instruments, as well as for different capillary lengths and diameters. Accuracy was verified by comparing the viscosity data obtained by CE instrumentation with those obtained by plate/cone rheometry. The suitability of the method for protein formulations was demonstrated, and limitations were discussed. Typical viscosities in the range of 5-40mPas were reliably measured with this method. Advantages of the CE instrumentation-based method included short measurement times (1-15min), small sample volumes (few microliters) for a capillary with a diameter of 50μm and a length of 20.5cm as well as potential to be suitable for high-throughput measurements.
Copyright © 2014 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Capillary electrophoresis; Capillary viscosimeter; High-throughput; Protein formulation; Viscosity

Mesh:

Substances:

Year:  2014        PMID: 25077704     DOI: 10.1016/j.jpba.2014.07.005

Source DB:  PubMed          Journal:  J Pharm Biomed Anal        ISSN: 0731-7085            Impact factor:   3.935


  3 in total

1.  Investigating the Role of Artemin Glycosylation.

Authors:  Qiu Danwen; Christian Code; Chao Quan; Bang-Jin Gong; Joseph Arndt; Blake Pepinsky; Kasper D Rand; Damian Houde
Journal:  Pharm Res       Date:  2016-02-23       Impact factor: 4.200

2.  Early developability screen of therapeutic antibody candidates using Taylor dispersion analysis and UV area imaging detection.

Authors:  Alexandra Lavoisier; Jean-Marc Schlaeppi
Journal:  MAbs       Date:  2015       Impact factor: 5.857

3.  Capillary Sodium Dodecyl Sulfate Agarose Gel Electrophoresis of Proteins.

Authors:  Daniel Sarkozy; Andras Guttman
Journal:  Gels       Date:  2022-01-19
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.